+852-3069 6950
css@gugent.com.hk
 

Agilent Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is available in single quadrupole and triple quadrupole configurations. Our single quadrupole ICP-MS address the range of typical ICP-MS measurements from routine, regulated analysis to advanced research and demanding applications. Our triple quadrupole ICP-MS will give you the confidence of knowing you can resolve problematic interferences – even in your most difficult samples – delivering results you know you can trust.

Catalog No. Product Net Price
G3286-80330 Z-axis drive assembly with nylon cable (PEEK, anti-kink). Suits Agilent ASX 520 autosampler used with Agilent 7700/8800 Series ICP-MS 1041 
Add to Cart
  • UNSPSC Code
  • 41113000
  • Autosampler Compatibility
  • ASX 500
G8410-80124 Barb connector, 2.5 mm to 1.5 mm id. Straight-through connector for rinse tube kit used with low volatile organic solvents in rinse station of Agilent SPS 4 autosampler. 11 
Add to Cart
  • UNSPSC Code
  • 41113000
  • Autosampler Compatibility
  • SPS 4
  • Where Used
  • Tubing connector
AGIL9910057200 Sample compartment O-ring kit; includes all O-rings for the spray chamber area, demountable torch and ASA (compatible with 700 Series and Liberty ICP-OES only) 83 
Add to Cart
  • UNSPSC Code
  • 41115411
AGIL9910105400 Tubing and connectors kit for Agilent radial ICP. Includes two packs of standard peristaltic pump tubing, snap connectors and other tubing/connectors used in sample compartment and torch box area. Ideal for spare start-up kit. 258 
Add to Cart
  • UNSPSC Code
  • 41115411
G8000-68004 Organics Kit for 4100 MP-AES. Adapts the 4100 MP-AES for determination of organic solvents. 3576 
Add to Cart
  • UNSPSC Code
  • 41113000
G8003-67001 Aqueous sample introduction kit, for Agilent MP-AES. Recommended for routine analysis of aqueous or acidic samples where a glass concentric nebulizer is required. Includes single pass glass cyclonic spray chamber (G8000-70006), Conikal nebulizer (2010106 1356 
Add to Cart
  • UNSPSC Code
  • 41113000
  • Notes
  • Recommended for routine analysis of aqueous or acidic samples
G3280-80602 Total consumption nebulizer, suits capillary LC interface kit used with Agilent ICP-MS. Used together with single-pass spray chamber G3280-80603 3977 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Autosampler Compatibility
  • None
  • Chemical Compatibility
  • Aqueous Organic solvents
  • Nebulizer Sample Particle Size Tolerance
  • 20 µm
  • Self Aspirating
  • Yes,
G3280-80603 Spray chamber, single-pass, suitable for capillary LC interface and very low-flow sample introduction applications. For use with total consumption nebulizer (G3280-80602) for capillary LC interface kit. Suitable for all Agilent ICP-MS 1201 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Chemical Compatibility
  • Aqueous Organic solvents
  • Material
  • Quartz
  • Type
  • Single pass
  • Volume
  • 8 mL
AGIL8003-0511 PerkinElmer NexION Sample introduction kit, HF-resistant, PFA-Platinum, for analysis of semiconductor-grade chemicals. Includes 2 PFA MicroFlow nebulizers, PFA endcap with extra gas port, PFA spray chamber, Pt injector and shield, quartz torch 10213 
Add to Cart
  • UNSPSC Code
  • 41122000
AGIL8003-0512 PerkinElmer NexION Sample introduction kit, HF-resistant, PFA-Sapphire, chemically inert. Includes a PFA-ST nebulizer, PFA endcap with additional gas port, PFA spray chamber, Sapphire injector, Pt Shield, quartz torch 6140 
Add to Cart
  • UNSPSC Code
  • 41122000

Overview

ICP-MS system operates with an ICP-MS Nebulizer, in which a high velocity Argon gas stream meets a liquid stream causing filmwise breakup of the solution into a fine aerosol. The aerosol particle size should ideally be sub-10µm with a narrow particle size distribution to achieve efficient atomization and ionization. Agilent offers a comprehensive range of ICP-MS nebulizers and supplies to solve any ICP-MS analysis challenge.

The portfolio includes standard glass concentric nebulizer (MicroMist), quartz and inert PFA nebulizers (MicroFlow and C-Flow), as well as robust Mira Mist PEEK or PTFE for high TDS samples and low-flow self-aspirating or total consumption nebulizers for your clinical or limited volume samples. ICP-MS nebulizer support is provided with a full range of accessories for all models including nebulizer cleaning tools.


The ICP torch is used to form, shape, and sustain an argon plasma which atomizes and ionizes the sample aerosol. Agilent ICP-MS Torches with Shield Torch System (STS) provide precise ion energy control, ensuring high sensitivity and stability, even in cool plasma mode for effective interference removal (ArO+).

Our portfolio is comprised of a wide range of ICP torches for your specific ICP-MS configuration. One-piece quartz torches offer the best stability and ease of use. The large 2.5mm injector on the standard torch gives maximum robustness and lowest matrix interferences for the best plasma stability. Single-piece torches with narrow bore injectors (1.0mm or 1.5 mm) are designed for use with organic solvents, to reduce plasma loading and improve plasma stability. Optional semi-demountable quartz torches with removable platinum or sapphire injectors are also available for use with the PFA inert sample introduction kit.


Resources