Water or air, measure H2S where it matters – right at the source.
Meet the new GS1440 and GS1440EX hydrogen sulfide sensors from Hach. Whether in water or air, you will have the direct H2S measurement you need to optimize your H2S treatment process and proactively control H2S before it causes issues.
CE approved (with all sensor types). Listed for use in general locations to UL and CSA safety standards by ETL (with all sensor types).Certain AC mains powered models are listed for use in general safety locations to UL and CSA safety standards by Underwriters Laboratories (with all sensor types).
Conduit Openings
½" NPT conduit
Dimensions
½ DIN - 144 x 144 x 192 mm (5.7 x 5.7 x 7.6 in.)
Display
None
Enclosure Rating
NEMA 4X/IP66 metal enclosure with a corrosion-resistant finish
LAN version: Two Ethernet connectors (10/100 Mbps), switch function, M12 female D-coding connector.Cellular version: SIM card holder (3G/4G).The type of connection is dependent on controller configuration.
Operating Temperature Range
LAN version: -20 - 60 °C (-4 - 140 °F)Cellular version: -20 - 55 °C (-4 - 131 °F)
Outputs
5x mA Output
Pollution Degree
2
Protection Class
I, connected to protective earth
Relays
High voltage:Two relays (SPDT)Maximum switching voltage: 250 VACMaximum switching current: 5 A (resistive only load)Maximum switching power: 1250 VA, 125 W (resistive only load)Wire gauge: 0.75 to 2.5 mm2 (18 to 12 AWG)Low voltage:Four relays on each low voltage relay module
Range at 25 °C (77 °F)2935A-A: 10 ppb - 400 ppm or 20 Pa - 1,000 kPa2952A-A: 1 ppb - 80 ppm or 5 Pa - 200 kPa2956A-A: 0.1 ppb - 20 ppm or 0.25 Pa - 50 kPa29552A-A: 2 ppb - 80 ppm or 5 Pa - 200 kPa
Warranty
6 months
Weight
0.3 kg (0.66 lbs)
What's included?
Oxygen Sensor (GA2400-S00), incl. plastic screw-on storage cap for sensor head protection; protection cap without grille (33051-S0); protection cap with grille (33051-SP)
Turbidity: Formazin or STABLCAL Standard (at 800 NTU). Suspended Solids: Sample specific, based on gravimetric TSS analysis with a correction factor procedure.
Certifications
CE, MCERTS
Controller
Sensor only
Diameter Sensor
60 mm
Flow
Max. 3 m/s (the presence of air bubbles affects the measurement)
Infrared Duo scattered light technique for color-independent turbidity measurement Turbidity in accordance with DIN EN ISO 7027 / TS equivalent DIN 38414
Model
Solitax highline sc
Mounting
Insertion
Operating Temperature Range
0 - 40 °C
Parameter
High Range Suspended Solids, Turbidity
Pressure Range
Stainless steel insertion sensor: <6 bar or <60 m
Range
TSS-content: 0.001 - 500 g/L; 0.001 - 500,000 mg/L (the upper range is dependent on the sample property)Turbidity: 0.001 - 4000 NTU
Repeatability
TSS content: < 3 %Turbidity: < 1 %
Response Time T90
1 - 300 s adjustable
Special Notes