PRO-E3A1N
PRO Series Transmitter, Electrodeless Conductivity
752
Add to Cart
Display
2-line by 16 character LCD
Material
Enclosure: Polycarbonate
Operating Temperature Range
-20 - 60 °C at 0 - 95% RH (non-condensing)
Parameter
Electrodeless Conductivity
Power Requirements (Voltage)
12 - 30 V DC
Repeatability
± 0.05 % of span, at 25 °C
Response Time T90
60 s
Storage Conditions
-30 to 70 °C 0-95% Relative humidity, non-condensing
Warranty
12 months
Weight
0.280 kg
What's included?
Controller, User Manual
K1200-S00
Orbisphere K1200 LDO Oxygen sensor, 0 - 2000 ppb, 28 mm Orbisphere fitting
Special offer
Add to Cart
Certifications
2004/108/EC - EN 61326-1
Communication Capabilities
3 x 0/4-20 mA; RS485; Ethernet
Mounting
28 mm Orbisphere fitting
Parameter
Oxygen
Power Requirements (Voltage)
100 - 230 VAC
Range
0 - 2000 ppb dissolved O2 (DO)
Relays
Measurement board: 3 measurement alarm relays (1A-30 VAC or 0.5A-50 VDC), configurable to send diagnostics information. Main board: 1 system alarm relay (1A-30 VAC or 0.5A-50 VDC).
Repeatability
± 0.4 ppb or 1 % whichever is greater
Sensors
K1200 LDO
Storage Conditions
-5 °C - 100 °C
Warranty
12 months
What's included?
K1200 Sensor only.Controller 510, sensor cable, flow-chamber or process connection must be ordered separately.
K1200-S00H
Orbisphere K1200 LDO Oxygen sensor, 0 - 40 ppm, 28 mm Orbisphere fitting
Special offer
Add to Cart
Certifications
2004/108/EC - EN 61326-1
Communication Capabilities
3 x 0/4-20 mA; RS485; Ethernet
Mounting
28 mm Orbisphere fitting
Parameter
Oxygen
Power Requirements (Voltage)
100 - 230 VAC
Range
0 - 40 ppm dissolved O2 (DO)
Relays
Measurement board: 3 measurement alarm relays (1A-30 VAC or 0.5A-50 VDC), configurable to send diagnostics information. Main board: 1 system alarm relay (1A-30 VAC or 0.5A-50 VDC).
Repeatability
± 0.015 ppm or 2 % whichever is greater
Sensors
K1200 LDO
Storage Conditions
-5 °C - 100 °C
Warranty
12 months
What's included?
K1200 Sensor only.Controller 510, sensor cable, flow-chamber or process connection must be ordered separately.
K1100-S00H
Orbisphere K1100 LDO Oxygen sensor, 0 - 40 ppm, 28 mm Orbisphere fitting
Special offer
Add to Cart
Certifications
2004/108/EC - EN 61326-1
Communication Capabilities
3 x 0/4-20 mA; RS485; Ethernet
Mounting
28 mm Orbisphere fitting
Parameter
Oxygen
Power Requirements (Voltage)
100 - 230 VAC
Range
0 - 40 ppm dissolved O2 (DO)
Relays
Measurement board: 3 measurement alarm relays (1A-30 VAC or 0.5A-50 VDC), configurable to send diagnostics information. Main board: 1 system alarm relay (1A-30 VAC or 0.5A-50 VDC).
Repeatability
± 0.015 ppm or 2 % whichever is greater
Sensors
K1100 LDO
Storage Conditions
-5 °C - 100 °C
Warranty
12 months
What's included?
K1100 Sensor onlyController, sensor cable, flow-chamber or process connection must be ordered separately
DGK510KK-W1025
Kit: Dual-channel Orbisphere 510 controller, 2x K1100 LDO sensors (0-2000 ppb), 2x 6 mm flow chamber, wall mount
Special offer
Add to Cart
Certifications
2004/108/EC - EN 61326-1
Communication Capabilities
3 x 0/4-20 mA; RS485; Ethernet
Controller
Wall
Mounting
Two 6 mm flow chambers
Parameter
Oxygen
Power Requirements (Voltage)
100 - 230 VAC
Range
0 - 2000 ppb dissolved O₂ (DO)
Relays
Measurement board: 3 measurement alarm relays (1A-30 VAC or 0.5A-50 VDC), configurable to send diagnostics information. Main board: 1 system alarm relay (1A-30 VAC or 0.5A-50 VDC).
Repeatability
± 0.4 ppb or 1 % whichever is greater
Sensors
Two K1100 LDO
Storage Conditions
-5 °C - 100 °C
Warranty
12 months
What's included?
1x Orbisphere controller 510KK0/W1C00000, 2x K1100-S00 sensor (low level), 2x 6 mm flow chamber 32001.010, 2x 32510.05 Sensor cable (5 m) to connect M/K-type sensor with Orbisphere 510 instruments
K1100-KTO-P-MET
Orbisphere K1100 LDO Sensor Kit, 0-2000 ppb, 410 controller, 6 mm flow chamber, panel mount
Special offer
Add to Cart
Certifications
2004/108/EC - EN 61326-1
Communication Capabilities
3 x 0/4-20 mA; RS485; Ethernet
Controller
Panel
Mounting
6 mm flow chamber
Parameter
Oxygen
Power Requirements (Voltage)
100 - 230 VAC
Range
0 - 2000 ppb dissolved O₂ (DO)
Relays
Measurement board: 3 measurement alarm relays (1A-30 VAC or 0.5A-50 VDC), configurable to send diagnostics information. Main board: 1 system alarm relay (1A-30 VAC or 0.5A-50 VDC).
Repeatability
± 0.4 ppb or 1 % whichever is greater
Sensors
K1100 LDO
Storage Conditions
-5 °C - 100 °C
Warranty
12 months
What's included?
Includes 410 panel mount controller, K1100 LDO sensor (low level), 3 m sensor cable, stainless steel flow-chamber with 6 mm fittings
K1100-S00
Orbisphere K1100 Luminescent Dissolved oxygen (LDO) sensor for in-line applications, 0-2000 ppb, 28 mm Orbisphere fitting
Special offer
Add to Cart
Certifications
2004/108/EC - EN 61326-1
Communication Capabilities
3 x 0/4-20 mA; RS485; Ethernet
Mounting
28 mm Orbisphere fitting
Parameter
Oxygen
Power Requirements (Voltage)
100 - 230 VAC
Range
0 - 2000 ppb dissolved O2 (DO)
Relays
Measurement board: 3 measurement alarm relays (1A-30 VAC or 0.5A-50 VDC), configurable to send diagnostics information. Main board: 1 system alarm relay (1A-30 VAC or 0.5A-50 VDC).
Repeatability
± 0.4 ppb or 1 % whichever is greater
Sensors
K1100 LDO
Storage Conditions
-5 °C - 100 °C
Warranty
12 months
What's included?
K1100 Sensor only Controller, sensor cable, flow chamber or process connection must be ordered separately
HACH7300800
Flow cell for 1” NPT sensor
604
Add to Cart
HACH9012700
Analog Flow Sensor Input Module for SC200 Universal Controller
809
Add to Cart
Calibration Method
ZeroGLI DRY-CAL1-point sample
Length
181 mm
Range
Contacting Conductivity 0 - 2.000 µS/cm
What's included?
Module, Manual
HACH9328100
Hart Network Communication Module for SC200 Universal Controller
722
Add to Cart
Length
181 mm
Warranty
12 months
What's included?
Module, Manual