We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.
Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Bacterial Retention
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
Cartridge Nominal Length
3 in. (7.5 cm)
Catalogue Number
KHGEG03TT3
Chemistry
Polyethersulfone (PES)
Device Configuration
Capsule
Device Material
Polypropylene/Polysulfone
Device Size
3 in.
Diameter
10.7 cm (4.2 in.)
European Pressure Equipment Directive
EMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
Filtration Area
0.13 m²
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Housing Material
Polypropylene (PP)
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
Forward: 6.9 bar (100 psid) intermittent @ 25 °C; 5.5 bar (80 psid) @ 25 °C; 1.0 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C, intermittent
Maximum Inlet Pressure (psig)
80 psig
Maximum Inlet Pressure, bar (psi)
6.9 bar (100 psi) intermittent @ 25 °C; 5.5 bar (80 psi) @ 25 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
Maximum Inlet Temperature
25 °C
Media
Millipore Express® SHC
Non-Fiber Releasing
This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Outlet Connection
Sanitary Flange
Outlet Connection Diameter
1-1/2 in.
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥2 L
Pore Size
0.5 / 0.2 µm
Seal Material
Silicone (SI)
Sterility
Gamma
Sterilization
Gamma compatible to 45 kGy; 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
Support Material
Polyester
Trade Name
Millipore Express®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Bacterial Retention
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
Cartridge Nominal Length
3 in. (7.5 cm)
Catalogue Number
KHGEG03TT3
Chemistry
Polyethersulfone (PES)
Device Configuration
Capsule
Device Material
Polypropylene/Polysulfone
Device Size
3 in.
Diameter
10.7 cm (4.2 in.)
European Pressure Equipment Directive
EMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
Filtration Area
0.13 m²
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Housing Material
Polypropylene (PP)
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
Forward: 6.9 bar (100 psid) intermittent @ 25 °C; 5.5 bar (80 psid) @ 25 °C; 1.0 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C, intermittent
Maximum Inlet Pressure (psig)
80 psig
Maximum Inlet Pressure, bar (psi)
6.9 bar (100 psi) intermittent @ 25 °C; 5.5 bar (80 psi) @ 25 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
Maximum Inlet Temperature
25 °C
Media
Millipore Express® SHC
Non-Fiber Releasing
This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Outlet Connection
Sanitary Flange
Outlet Connection Diameter
1-1/2 in.
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥2 L
Pore Size
0.5 / 0.2 µm
Seal Material
Silicone (SI)
Sterility
Gamma
Sterilization
Gamma compatible to 45 kGy; 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
Support Material
Polyester
Trade Name
Millipore Express®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Bacterial Retention
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
Cartridge Nominal Length
3 in. (7.5 cm)
Catalogue Number
KVEPA03HH3
Chemistry
Polyethersulfone (PES)
Device Configuration
Capsule
Device Material
Polypropylene
Device Size
3 in.
Diameter
10.7 cm (4.2 in.)
European Pressure Equipment Directive
EMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
Filtration Area
0.16 m²
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Housing Material
Polypropylene (PP)
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
Forward: 6.9 bar (100 psid) intermittent @ 25 °C; 5.5 bar (80 psid) @ 25 °C; 1.0 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C, intermittent
Maximum Inlet Pressure (psig)
80 psig
Maximum Inlet Pressure, bar (psi)
6.9 bar (100 psi) intermittent @ 23 °C; 5.5 bar (80 psi) @ 23 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
Maximum Inlet Temperature
25 °C
Media
Millipore Express® SHR
Non-Fiber Releasing
This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Outlet Connection
Hose Barb
Outlet Connection Diameter
9/16 in.
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥1 L
Pore Size
0.1 µm
Seal Material
Silicone (SI)
Sterilization
3 autoclave cycles of 60 min @ 126 °C; not in-line steam sterilizable
Support Material
Polypropylene
Trade Name
Millipore Express®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Bacterial Retention
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
Catalogue Number
MSP010012
Chemistry
Polyvinylidene Fluoride (PVDF)
Device Configuration
Capsule
Diameter
9/16 in.
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Inlet Connection
Hose Barb
Inlet Connection Diameter
9/16 in.
Material Size
3
Media
Durapore®
Non-Fiber Releasing
This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Outlet Connection
Hose Barb
Outlet Connection Diameter
9/16 in.
Pore Size
0.22 µm
Sterility
Other
Trade Name
Durapore®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Bacterial Retention
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
Catalogue Number
MSP010013
Chemistry
Polyvinylidene Fluoride (PVDF)
Device Configuration
Capsule
Diameter
1-1/2 in.
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Inlet Connection
Sanitary Flange
Inlet Connection Diameter
1-1/2 in.
Material Size
3
Media
Durapore®
Non-Fiber Releasing
This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Outlet Connection
Sanitary Flange
Outlet Connection Diameter
1-1/2 in.
Pore Size
0.22 µm
Sterility
Other
Trade Name
Durapore®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
OverviewThe High Output Pump features a piston-driven design for greater power.The Chemical Duty Pump has a chemically-resistant head and diaphragm for use with corrosive chemicals and solvents.Both pumps come with 70 cm of 1/4" tubing and a Millex FA50 filter for in-line moisture protection. Both are UL listed and CE marked.The High Output and Chemical Duty pumps can support high flow rates to decrease process filtration time. The High Output Pump features a piston-driven design for greater power. The Chemical Duty Pump has a chemically-resistant head and diaphragm for use with corrosive chemicals and solvents. Both pumps come with 70 cm of 1/4 in. tubing and a Millex®-FA50 filter for in-line moisture protection. Both are UL-listed and CE-marked.Features & BenefitsHigh flow rates decrease filtration process time Optional chemical-resistant internal components for compatibility with corrosive vapors Portable design allows for easy sharing between workstations ApplicationsVacuum Source for Filter Holders, Manifolds, and Devices, including Samplicity® Filtration System, SNAP i.d.® 2.0 System, Multiscreen®HTS Filtration Manifold, and Stericup® FiltersFor more information visit the EMDMillipore Vacuum Hardware site.
OverviewThe High Output Pump features a piston-driven design for greater power.The Chemical Duty Pump has a chemically-resistant head and diaphragm for use with corrosive chemicals and solvents.Both pumps come with 70 cm of 1/4" tubing and a Millex FA50 filter for in-line moisture protection. Both are UL listed and CE marked.The High Output and Chemical Duty pumps can support high flow rates to decrease process filtration time. The High Output Pump features a piston-driven design for greater power. The Chemical Duty Pump has a chemically-resistant head and diaphragm for use with corrosive chemicals and solvents. Both pumps come with 70 cm of 1/4 in. tubing and a Millex®-FA50 filter for in-line moisture protection. Both are UL-listed and CE-marked.Features & BenefitsHigh flow rates decrease filtration process time Optional chemical-resistant internal components for compatibility with corrosive vapors Portable design allows for easy sharing between workstations ApplicationsVacuum Source for Filter Holders, Manifolds, and Devices, including Samplicity® Filtration System, SNAP i.d.® 2.0 System, Multiscreen®HTS Filtration Manifold, and Stericup® FiltersFor more information visit the EMDMillipore Vacuum Hardware site.
Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.
Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.