+852-3069 6950
css@gugent.com.hk
 

We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.

Catalog No. Product Net Price
CN03F1E06 Polygard-CN Cartridge Filter 10 in. 0.3 µm Code F Ethylene-Propylene 691 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code F double open end w/flat gaskets
  • Cartridge Nominal Length
  • 10 in. (25 cm)
  • Catalogue Number
  • CN03F1E06
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Filtration Area
  • 0.42 m²
  • Gravimetric Extractables
  • ≤50 mg after 24-h soak in water
  • Length
  • 10 in. (25 cm)
  • Material Size
  • 6
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 0.3 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥5 L
  • Pore Size
  • 0.3 µm
  • Sanitization
  • 30 min with hot water @ 80 °C
  • Seal Material
  • Ethylene Propylene
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Polygard®
  • Wettability
  • Hydrophilic
CGEP71TP3 Millipore Express® SHF Cartridge Filter 10 in. 0.2 µm Code 7 Silicone 692 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Bacterial Retention
  • Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
  • Cartridge Code
  • Code 7
  • Cartridge Nominal Length
  • 10 in. (25 cm)
  • Catalogue Number
  • CGEP71TP3
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene/Polysulfone
  • Device Size
  • 10 in.
  • Diameter
  • 6.9 cm (2.7 in.)
  • Filtration Area
  • 0.54 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Length
  • 10 in. (25 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 3
  • Maximum Differential Pressure
  • Forward: 6900 mbar (100 psi) @ 25 °C; 1700 bar (25 psi) @ 80 °C; 340 mbar (5 psi) @ 135 °C. Reverse: 2100 mbar (30 psi) @ 25 °C, 69 mbar (1 psi) @ 135 °C
  • Maximum Inlet Pressure, bar (psi)
  • Forward - 7 bar (100 psi) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; 0.35 bar (5 psi) @ 135 °C; Reverse - 2.07 bar (30 psi) @ 25 °C; 0.07 bar (1 psi) @ 135 °C
  • Media
  • Millipore Express® SHF
  • Non-Fiber Releasing
  • This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥1 L
  • Pore Size
  • 0.2 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 25 forward or 22 forward and 3 reverse SIP cycles of 30 min @ 135 °C; 25 autoclave cycles of 60 min @ 126 °C
  • Support Material
  • Polypropylene
  • Trade Name
  • Millipore Express®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Wettability
  • Hydrophilic
CGEP71TP3 Millipore Express® SHF Cartridge Filter 10 in. 0.2 µm Code 7 Silicone 692 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Bacterial Retention
  • Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
  • Cartridge Code
  • Code 7
  • Cartridge Nominal Length
  • 10 in. (25 cm)
  • Catalogue Number
  • CGEP71TP3
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene/Polysulfone
  • Device Size
  • 10 in.
  • Diameter
  • 6.9 cm (2.7 in.)
  • Filtration Area
  • 0.54 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Length
  • 10 in. (25 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 3
  • Maximum Differential Pressure
  • Forward: 6900 mbar (100 psi) @ 25 °C; 1700 bar (25 psi) @ 80 °C; 340 mbar (5 psi) @ 135 °C. Reverse: 2100 mbar (30 psi) @ 25 °C, 69 mbar (1 psi) @ 135 °C
  • Maximum Inlet Pressure, bar (psi)
  • Forward - 7 bar (100 psi) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; 0.35 bar (5 psi) @ 135 °C; Reverse - 2.07 bar (30 psi) @ 25 °C; 0.07 bar (1 psi) @ 135 °C
  • Media
  • Millipore Express® SHF
  • Non-Fiber Releasing
  • This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥1 L
  • Pore Size
  • 0.2 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 25 forward or 22 forward and 3 reverse SIP cycles of 30 min @ 135 °C; 25 autoclave cycles of 60 min @ 126 °C
  • Support Material
  • Polypropylene
  • Trade Name
  • Millipore Express®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Wettability
  • Hydrophilic
MCGL40S03 Millidisk® Cartridge 40-stack 0.22 µm Hydrophilic 696 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Bacterial Retention
  • Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
  • Cartridge Code
  • Not Applicable
  • Catalogue Number
  • MCGL40S03
  • Chemistry
  • Polyvinylidene Fluoride (PVDF)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polysulfone
  • Filtration Area
  • 2000 cm²
  • Flow Rate
  • 53 L/min @ 2.8 bar ΔP
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 10 mg per sterilized device after 24 hours in water at controlled room temperature.
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 3
  • Maximum Differential Pressure, bar (psid)
  • Forward: 4.1 bar (60 psid) @ 25 °C; 1.7 bar (25 psid) @ 80 °C; 0.35 bar (5 psid) @ 123 °C; Reverse: 0.7 bar (10 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • Forward - 4.1 bar (60 psi) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; 0.35 bar (5 psi) @ 123 °C; Reverse - 0.7 bar (10 psi) @ 25 °C
  • Media
  • Durapore®
  • Non-Fiber Releasing
  • This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥200 mL
  • Pore Size
  • 0.22 µm
  • Seal Material
  • Silicone (SI)
  • Sterility
  • Other
  • Sterilization
  • 5 SIP cycles of 60 min @ 135 °C; 5 autoclave cycles of 60 min @ 126 °C
  • Support Material
  • Polysulfone
  • Trade Name
  • Millidisk®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Wettability
  • Hydrophilic
MCGL40S03 Millidisk® Cartridge 40-stack 0.22 µm Hydrophilic 696 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Bacterial Retention
  • Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
  • Cartridge Code
  • Not Applicable
  • Catalogue Number
  • MCGL40S03
  • Chemistry
  • Polyvinylidene Fluoride (PVDF)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polysulfone
  • Filtration Area
  • 2000 cm²
  • Flow Rate
  • 53 L/min @ 2.8 bar ΔP
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 10 mg per sterilized device after 24 hours in water at controlled room temperature.
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 3
  • Maximum Differential Pressure, bar (psid)
  • Forward: 4.1 bar (60 psid) @ 25 °C; 1.7 bar (25 psid) @ 80 °C; 0.35 bar (5 psid) @ 123 °C; Reverse: 0.7 bar (10 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • Forward - 4.1 bar (60 psi) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; 0.35 bar (5 psi) @ 123 °C; Reverse - 0.7 bar (10 psi) @ 25 °C
  • Media
  • Durapore®
  • Non-Fiber Releasing
  • This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥200 mL
  • Pore Size
  • 0.22 µm
  • Seal Material
  • Silicone (SI)
  • Sterility
  • Other
  • Sterilization
  • 5 SIP cycles of 60 min @ 135 °C; 5 autoclave cycles of 60 min @ 126 °C
  • Support Material
  • Polysulfone
  • Trade Name
  • Millidisk®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Wettability
  • Hydrophilic
SK2P012W6 Prostak™ MF Module 0.45 µm 2 stack 0.17 m2 700 
Add to Cart
  • Catalogue Number
  • SK2P012W6
  • Chemistry
  • Polyvinylidene Fluoride (PVDF)
  • Device Configuration
  • Module
  • Device Size
  • 2 Stack
  • Filter Code
  • HVHP
  • Filtration Area
  • 0.17 m²
  • Key Applications
  • Concentration and Clarification of cellsPerfusion
  • Material Size
  • 1
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 50 °C4.1 bar (60 psi) @ 50-80 °C
  • Maximum Transmembrane Pressure
  • 4.1 bar (60 psi) @ 50 °C2.1 bar (30 psi) @ 50-80 °C
  • Media
  • Durapore®
  • Membrane Area
  • 0.17 m²
  • pH Range
  • pH2 – pH12 ContinuouspH1 – pH13 Short Duration
  • Pore Size
  • 0.45 µm
  • Screen Type
  • Type V screen (open channel)
  • Seal Material
  • Module supplied with Silicone (SI) gaskets
  • Wettability
  • Hydrophobic
KHGES03HH3 Opticap® Sterile XL 3 Millipore Express® SHC 0.5/0.2 µm 9/16 in. HB/HB 706 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Bacterial Retention
  • Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
  • Cartridge Nominal Length
  • 3 in. (7.5 cm)
  • Catalogue Number
  • KHGES03HH3
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Capsule
  • Device Material
  • Polypropylene/Polysulfone
  • Device Size
  • 3 in.
  • Diameter
  • 10.7 cm (4.2 in.)
  • European Pressure Equipment Directive
  • EMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
  • Filtration Area
  • 0.13 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Housing Material
  • Polypropylene (PP)
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Hose Barb
  • Inlet Connection Diameter
  • 9/16 in.
  • Inlet to Outlet Width
  • 17.3 cm (6.8 in.)
  • Length
  • 3 in. (7.5 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 3
  • Maximum Differential Pressure
  • 80 psi (5.5 bar) continuous100 psi (6.9 bar) intermittent
  • Maximum Differential Pressure, bar (psid)
  • Forward: 6.9 bar (100 psid) intermittent @ 25 °C; 5.5 bar (80 psid) @ 25 °C; 1.0 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C, intermittent
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 6.9 bar (100 psi) intermittent @ 25 °C; 5.5 bar (80 psi) @ 25 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Millipore Express® SHC
  • Non-Fiber Releasing
  • This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Hose Barb
  • Outlet Connection Diameter
  • 9/16 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥2 L
  • Pore Size
  • 0.5 / 0.2 µm
  • Seal Material
  • Silicone (SI)
  • Sterility
  • Sterile
  • Sterilization
  • 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
  • Support Material
  • Polyester
  • Trade Name
  • Millipore Express®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Polypropylene (PP)
  • Wettability
  • Hydrophilic
  • Width
  • 17.3 cm (6.8 in.)
KHGES03HH3 Opticap® Sterile XL 3 Millipore Express® SHC 0.5/0.2 µm 9/16 in. HB/HB 706 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Bacterial Retention
  • Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
  • Cartridge Nominal Length
  • 3 in. (7.5 cm)
  • Catalogue Number
  • KHGES03HH3
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Capsule
  • Device Material
  • Polypropylene/Polysulfone
  • Device Size
  • 3 in.
  • Diameter
  • 10.7 cm (4.2 in.)
  • European Pressure Equipment Directive
  • EMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
  • Filtration Area
  • 0.13 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Housing Material
  • Polypropylene (PP)
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Hose Barb
  • Inlet Connection Diameter
  • 9/16 in.
  • Inlet to Outlet Width
  • 17.3 cm (6.8 in.)
  • Length
  • 3 in. (7.5 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 3
  • Maximum Differential Pressure
  • 80 psi (5.5 bar) continuous100 psi (6.9 bar) intermittent
  • Maximum Differential Pressure, bar (psid)
  • Forward: 6.9 bar (100 psid) intermittent @ 25 °C; 5.5 bar (80 psid) @ 25 °C; 1.0 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C, intermittent
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 6.9 bar (100 psi) intermittent @ 25 °C; 5.5 bar (80 psi) @ 25 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Millipore Express® SHC
  • Non-Fiber Releasing
  • This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Hose Barb
  • Outlet Connection Diameter
  • 9/16 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥2 L
  • Pore Size
  • 0.5 / 0.2 µm
  • Seal Material
  • Silicone (SI)
  • Sterility
  • Sterile
  • Sterilization
  • 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
  • Support Material
  • Polyester
  • Trade Name
  • Millipore Express®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Polypropylene (PP)
  • Wettability
  • Hydrophilic
  • Width
  • 17.3 cm (6.8 in.)
KHGES03TB3 Opticap® Sterile XL 3 Millipore Express® SHC 0.5/0.2 µm 1-1/2 in. TC-1 in. HB 706 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Bacterial Retention
  • Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
  • Cartridge Nominal Length
  • 3 in. (7.5 cm)
  • Catalogue Number
  • KHGES03TB3
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Capsule
  • Device Material
  • Polypropylene/Polysulfone
  • Device Size
  • 3 in.
  • Diameter
  • 10.7 cm (4.2 in.)
  • European Pressure Equipment Directive
  • EMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
  • Filtration Area
  • 0.13 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Housing Material
  • Polypropylene (PP)
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Sanitary Flange
  • Inlet Connection Diameter
  • 1-1/2 in.
  • Inlet to Outlet Width
  • 17.3 cm (6.8 in.)
  • Length
  • 3 in. (7.5 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 3
  • Maximum Differential Pressure
  • 80 psi (5.5 bar) continuous100 psi (6.9 bar) intermittent
  • Maximum Differential Pressure, bar (psid)
  • Forward: 6.9 bar (100 psid) intermittent @ 25 °C; 5.5 bar (80 psid) @ 25 °C; 1.0 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C, intermittent
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 6.9 bar (100 psi) intermittent @ 25 °C; 5.5 bar (80 psi) @ 25 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Millipore Express® SHC
  • Non-Fiber Releasing
  • This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Hose Barb
  • Outlet Connection Diameter
  • 1 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥2 L
  • Pore Size
  • 0.5 / 0.2 µm
  • Seal Material
  • Silicone (SI)
  • Sterility
  • Sterile
  • Sterilization
  • 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
  • Support Material
  • Polyester
  • Trade Name
  • Millipore Express®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Polypropylene (PP)
  • Wettability
  • Hydrophilic
  • Width
  • 17.3 cm (6.8 in.)
KHGES03TB3 Opticap® Sterile XL 3 Millipore Express® SHC 0.5/0.2 µm 1-1/2 in. TC-1 in. HB 706 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Bacterial Retention
  • Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
  • Cartridge Nominal Length
  • 3 in. (7.5 cm)
  • Catalogue Number
  • KHGES03TB3
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Capsule
  • Device Material
  • Polypropylene/Polysulfone
  • Device Size
  • 3 in.
  • Diameter
  • 10.7 cm (4.2 in.)
  • European Pressure Equipment Directive
  • EMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
  • Filtration Area
  • 0.13 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Housing Material
  • Polypropylene (PP)
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Sanitary Flange
  • Inlet Connection Diameter
  • 1-1/2 in.
  • Inlet to Outlet Width
  • 17.3 cm (6.8 in.)
  • Length
  • 3 in. (7.5 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 3
  • Maximum Differential Pressure
  • 80 psi (5.5 bar) continuous100 psi (6.9 bar) intermittent
  • Maximum Differential Pressure, bar (psid)
  • Forward: 6.9 bar (100 psid) intermittent @ 25 °C; 5.5 bar (80 psid) @ 25 °C; 1.0 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C, intermittent
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 6.9 bar (100 psi) intermittent @ 25 °C; 5.5 bar (80 psi) @ 25 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Millipore Express® SHC
  • Non-Fiber Releasing
  • This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Hose Barb
  • Outlet Connection Diameter
  • 1 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥2 L
  • Pore Size
  • 0.5 / 0.2 µm
  • Seal Material
  • Silicone (SI)
  • Sterility
  • Sterile
  • Sterilization
  • 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
  • Support Material
  • Polyester
  • Trade Name
  • Millipore Express®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Polypropylene (PP)
  • Wettability
  • Hydrophilic
  • Width
  • 17.3 cm (6.8 in.)

Overview

Analytical Sample Preparation Membrane Filtration Devices


Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.


Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.


Filter Membranes

Millex® Syringe Filters

Filtration Holders & Accessories



Resources