MN702168
Screw closure (bonded), N 24, PP, white, c.hole,lid,Sil. nat./PTFE colorl.,3.2mm
Special offer
Add to Cart
Hazardous material
No
Nominal diameter
N 24
Recommended application(s)
Storage of liquid samples, TOC/VOC
Autosampler compatibility
Agilent/Tekmar AQUATek 70, Agilent/Tekmar SOLAtek 72, Agilent/Varian Archon Purge + Trap, Agilent 7695A, Analytik Jena multi N/C 3000 (TOC), Dimatec Dimatoc 200 / 300 / 400, Dionex ASE 200, GE Instruments Sievers 900, Hach Lange IL 550 TOC-TN, IMT GmbH VSP4000, O.I. Analytical 1020A / 1088 / 1096+ / 4551A / 1552, Shimadzu ASI-V, Teledyne Tekmar STS 8000 TOC, Thermo Scientific HiPerTOC, Viscotek Vartex
Storage temperature
RT
Scope of delivery
100x N 24 bonded screw closures
Closure type
Screw closure
Assembling process
Bonded
Cap material
Polypropylene (PP)
Cap color
White
Cap hole
Yes
Closure magnetic
No
Septa material
Silicone/PTFE
Colors of septa material
Natural/colorless
Septa thickness
3.2 mm
Septa hardness
45° shore A
Additional closure features
Temp. resistance septa -60 °C up to 200 °C - however, PP cap only up to 120 °C / analytical purity - high / easy to penetrate / medium resealability
Additional cap features
With removable protection lid
MN702028
Screw closure (bonded), N 9, PP, blue, center hole, Red Rubber/TEF, 1.0 mm
Special offer
Add to Cart
Hazardous material
No
Nominal diameter
N 9
Recommended application(s)
GC, HPLC
Autosampler compatibility
Knauer, PerkinElmer
Storage temperature
RT
Scope of delivery
100x N 9 bonded screw closures
Closure type
Screw closure
Assembling process
Bonded
Cap material
Polypropylene (PP)
Cap color
Blue
Cap hole
Yes
Closure magnetic
No
Septa material
Red Rubber/PTFE
Colors of septa material
Red-orange/colorless
Septa thickness
1.0 mm
Septa hardness
65° shore A
Additional closure features
Temp. resistance -40 °C up to 110 °C / analytical purity - medium / medium hard to penetrate / medium resealability
Additional cap features
9 mm thread is not standardized
MN702026
Screw closure (bonded), N 9, PP,blue,center hole,Silic. beige/PTFE white, 1.3 mm
Special offer
Add to Cart
Hazardous material
No
Nominal diameter
N 9
Recommended application(s)
GC, HPLC
Autosampler compatibility
Agilent, CTC, Dionex, Knauer, PerkinElmer, Shimadzu, Thermo Scientific, VWR, Waters
Storage temperature
RT
Scope of delivery
100x N 9 bonded screw closures
Closure type
Screw closure
Assembling process
Bonded
Cap material
Polypropylene (PP)
Cap color
Blue
Cap hole
Yes
Closure magnetic
No
Septa material
Silicone/PTFE
Colors of septa material
Beige/white
Septa thickness
1.3 mm
Septa hardness
45° shore A
Additional closure features
Temp. resistance septa -60 °C up to 200 °C - however, PP cap only up to 120 °C / analytical purity - high / easy to penetrate / medium resealability
Additional cap features
9 mm thread is not standardized
MN702027
Screw closure (bonded), N 9, PP,blue,center hole,Silic. beige/PTFE w.,slit,1.3mm
Special offer
Add to Cart
Hazardous material
No
Nominal diameter
N 9
Recommended application(s)
HPLC
Autosampler compatibility
Agilent, CTC, Dionex, PerkinElmer, Shimadzu, Thermo Scientific, VWR, Waters
Storage temperature
RT
Scope of delivery
100x N 9 bonded screw closures
Closure type
Screw closure
Assembling process
Bonded
Cap material
Polypropylene (PP)
Cap color
Blue
Cap hole
Yes
Closure magnetic
No
Septa material
Silicone/PTFE, slit
Colors of septa material
Beige/white
Septa thickness
1.3 mm
Septa hardness
45° shore A
Additional closure features
Slit as penetration aid for blunt HPLC needles and for avoidance of a vacuum inside the vial in case of multiple injections
Additional cap features
9 mm thread is not standardized
MN702115
Screw closure (bonded), N 18, PP, white, closed top,Silicone w./PTFE blue, 1.3mm
Special offer
Add to Cart
Hazardous material
No
Nominal diameter
N 18
Recommended application(s)
Storage of liquid samples
Storage temperature
RT
Scope of delivery
100x N 18 bonded screw closures
Closure type
Screw closure
Assembling process
Bonded
Cap material
Polypropylene (PP)
Cap color
White
Cap hole
No
Closure magnetic
No
Septa material
Silicone/PTFE
Colors of septa material
White/blue
Septa thickness
1.3 mm
Septa hardness
55° shore A
Additional closure features
Temp. resistance septa -60 °C up to 200 °C - however, PP cap only up to 120 °C / analytical purity - high
MN702995
Crimp closure, N 11, alu., center hole, PTFE red/Silicone white/PTFE red, 1.0 mm
Special offer
Add to Cart
Hazardous material
No
Nominal diameter
N 11
Recommended application(s)
GC, HPLC
Autosampler compatibility
Agilent, CTC, PerkinElmer, Shimadzu, Varian, Waters
Storage temperature
RT
Scope of delivery
100x N 11 ready assembled crimp closures
Closure type
Crimp closure
Assembling process
Assembled
Cap material
Aluminum
Cap color
Silver
Cap hole
Yes
Closure magnetic
No
Septa material
PTFE/Silicone/PTFE
Colors of septa material
Red/white/red
Septa thickness
1.0 mm
Septa hardness
50° shore A
Additional closure features
Temp. resistance -60 °C up to 200 °C / analytical purity - high / easy to medium hard to penetrate / low resealability, but very low fragmentation
MN702995.1
Crimp closure, N 11, alu., green,center hole,PTFE red/Silicone w./PTFE red,1.0mm
Special offer
Add to Cart
Hazardous material
No
Nominal diameter
N 11
Recommended application(s)
GC, HPLC
Autosampler compatibility
Agilent, CTC, PerkinElmer, Shimadzu, Varian, Waters
Storage temperature
RT
Scope of delivery
100x N 11 ready assembled crimp closures
Closure type
Crimp closure
Assembling process
Assembled
Cap material
Aluminum
Cap color
Green
Cap hole
Yes
Closure magnetic
No
Septa material
PTFE/Silicone/PTFE
Colors of septa material
Red/white/red
Septa thickness
1.0 mm
Septa hardness
50° shore A
Additional closure features
Temp. resistance -60 °C up to 200 °C / analytical purity - high / easy to medium hard to penetrate / low resealability, but very low fragmentation
MN702995.2
Crimp closure, N 11, alu., red, center hole, PTFE red/Silicone w./PTFE red,1.0mm
Special offer
Add to Cart
Hazardous material
No
Nominal diameter
N 11
Recommended application(s)
GC, HPLC
Autosampler compatibility
Agilent, CTC, PerkinElmer, Shimadzu, Varian, Waters
Storage temperature
RT
Scope of delivery
100x N 11 ready assembled crimp closures
Closure type
Crimp closure
Assembling process
Assembled
Cap material
Aluminum
Cap color
Red
Cap hole
Yes
Closure magnetic
No
Septa material
PTFE/Silicone/PTFE
Colors of septa material
Red/white/red
Septa thickness
1.0 mm
Septa hardness
50° shore A
Additional closure features
Temp. resistance -60 °C up to 200 °C / analytical purity - high / easy to medium hard to penetrate / low resealability, but very low fragmentation
MN702995.3
Crimp closure, N 11, alu., blue, center hole,PTFE red/Silicone w./PTFE red,1.0mm
Special offer
Add to Cart
Hazardous material
No
Nominal diameter
N 11
Recommended application(s)
GC, HPLC
Autosampler compatibility
Agilent, CTC, PerkinElmer, Shimadzu, Varian, Waters
Storage temperature
RT
Scope of delivery
100x N 11 ready assembled crimp closures
Closure type
Crimp closure
Assembling process
Assembled
Cap material
Aluminum
Cap color
Blue
Cap hole
Yes
Closure magnetic
No
Septa material
PTFE/Silicone/PTFE
Colors of septa material
Red/white/red
Septa thickness
1.0 mm
Septa hardness
50° shore A
Additional closure features
Temp. resistance -60 °C up to 200 °C / analytical purity - high / easy to medium hard to penetrate / low resealability, but very low fragmentation
MN702035
Screw closure, N 9, PP, blue, center hole,PTFE red/Silicone white/PTFE red,1.0mm
Special offer
Add to Cart
Hazardous material
No
Nominal diameter
N 9
Recommended application(s)
GC, HPLC
Autosampler compatibility
Agilent, CTC, Varian
Storage temperature
RT
Scope of delivery
100x N 9 ready assembled screw closures
Closure type
Screw closure
Assembling process
Assembled
Cap material
Polypropylene (PP)
Cap color
Blue
Cap hole
Yes
Closure magnetic
No
Septa material
PTFE/Silicone/PTFE
Colors of septa material
Red/white/red
Septa thickness
1.0 mm
Septa hardness
50° shore A
Additional closure features
Temp. resistance septa -60 °C up to 200 °C - however, PP cap only up to 120 °C / analytical purity - high / easy to medium hard to penetrate / low resealability, but very low fragmentation