+852-3069 6950
css@gugent.com.hk
 

About 30 years ago MACHEREY‑NAGEL designed and introduced CHROMABOND SPE cartridges containing silica-based adsorbents.

SPE is a form of digital (step-wise) chromatography designed to extract, partition, and / or adsorb one or more components from a liquid phase (sample) onto a stationary phase (adsorbent or resin). An adsorbed substance can be removed from the adsorbent by stepwise increase of elution strength of the eluent (step gradient technique).

SPE extends a chromatographic system’s lifetime, improves qualitative and quantitative analysis, and the demand placed on an analytical instrument is considerably lessened.


Catalog No. Product Net Price
MN730111.AOX SPE columns, CHROMABOND HR-P AOX, 50–100 µm, 6 mL/500 mg Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE)
  • Brand
  • CHROMABOND
  • Phase
  • HR-P AOX
  • Mode
  • Reversed phase (RP)
  • Base material
  • PS/DVB copolymer
  • Surface chemistry
  • Special polystyrene-divinylbenzene copolymer (PS/DVB)
  • Column type
  • SPE column
  • Hardware
  • Polypropylene (PP) columns with polyethylene (PE) filter elements
  • Column shape
  • Open tubular syringe-shaped column with Luer tip outlet
  • Column volume
  • 6 mL
  • Filling quantity
  • 500 mg
  • Column volume/adsorbent weight
  • 6 mL/500 mg
  • Recommended application(s)
  • Extraction of AOX from water containing high salt loads or organic pollutants in accordance with DIN 38409 – H22
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 50–100 µm
  • Particle shape
  • Irregular
  • pH stability
  • 1.0–14.0
  • Filter element material
  • Polyethylene (PE)
  • Storage temperature
  • RT
MN730119.AOX SPE columns, CHROMABOND HR-P AOX, 50–100 µm, 6 mL/200 mg Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE)
  • Brand
  • CHROMABOND
  • Phase
  • HR-P AOX
  • Mode
  • Reversed phase (RP)
  • Base material
  • PS/DVB copolymer
  • Surface chemistry
  • Special polystyrene-divinylbenzene copolymer (PS/DVB)
  • Column type
  • SPE column
  • Hardware
  • Polypropylene (PP) columns with polyethylene (PE) filter elements
  • Column shape
  • Open tubular syringe-shaped column with Luer tip outlet
  • Column volume
  • 6 mL
  • Filling quantity
  • 200 mg
  • Column volume/adsorbent weight
  • 6 mL/200 mg
  • Recommended application(s)
  • Extraction of AOX from water containing high salt loads or organic pollutants in accordance with DIN 38409 – H22
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 50–100 µm
  • Particle shape
  • Irregular
  • pH stability
  • 1.0–14.0
  • Filter element material
  • Polyethylene (PE)
  • Storage temperature
  • RT
MN730135 SPE columns, CHROMABOND CN/SiOH, 45 µm, 6 mL/500/1000 mg Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE)
  • Brand
  • CHROMABOND
  • Phase
  • CN/SiOH
  • Mode
  • Special application or diverse
  • Base material
  • Silica gel
  • Surface chemistry
  • Special combination of cyanopropyl (CN) and unmodified silica gel (SiOH)
  • Column type
  • SPE column
  • Hardware
  • Polypropylene (PP) columns with polyethylene (PE) filter elements
  • Column shape
  • Open tubular syringe-shaped column with Luer tip outlet
  • Column volume
  • 6 mL
  • Filling quantity
  • 500/1000 mg
  • Column volume/adsorbent weight
  • 6 mL/500/1000 mg
  • Selling unit
  • 30 columns, 250 columns
  • Recommended application(s)
  • Extraction of 16 PAHs according to EPA from soil samples
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 45 µm
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • pH stability
  • 2.0–8.0
  • Filter element material
  • Polyethylene (PE)
  • Storage temperature
  • RT
MN730135G SPE glass columns, CHROMABOND CN/SIOH, 45 µm, 6 mL/500/1000mg Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE)
  • Brand
  • CHROMABOND
  • Phase
  • CN/SiOH
  • Mode
  • Special application or diverse
  • Base material
  • Silica gel
  • Surface chemistry
  • Special combination of cyanopropyl (CN) and unmodified silica gel (SiOH)
  • Column type
  • SPE glass column
  • Hardware
  • Glass columns (borosilicate type I) with glass fiber (GF) filter elements
  • Column shape
  • Open tubular syringe-shaped column with Luer tip outlet
  • Column volume
  • 6 mL
  • Filling quantity
  • 500/1000 mg
  • Column volume/adsorbent weight
  • 6 mL/500/1000mg
  • Recommended application(s)
  • Extraction of 16 PAHs according to EPA from soil samples
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 45 µm
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • pH stability
  • 2.0–8.0
  • Filter element material
  • Glass fiber (GF)
  • Storage temperature
  • RT
MN730168 SPE columns, CHROMABOND Drug, 45 µm, 3 mL/200 mg Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE)
  • Brand
  • CHROMABOND
  • Phase
  • Drug
  • Mode
  • Special application or diverse
  • Base material
  • Silica gel
  • Surface chemistry
  • Special bifunctional modification - C8/SA (octyl phase/strong cation exchanger – benzenesulfonic acid)
  • Column type
  • SPE column
  • Hardware
  • Polypropylene (PP) columns with polyethylene (PE) filter elements
  • Column shape
  • Open tubular syringe-shaped column with Luer tip outlet
  • Column volume
  • 3 mL
  • Filling quantity
  • 200 mg
  • Column volume/adsorbent weight
  • 3 mL/200 mg
  • Selling unit
  • 50 columns, 250 columns
  • Recommended application(s)
  • Enrichment of acidic, neutral and basic drugs from urine or plasma
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 45 µm
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • pH stability
  • 2.0–8.0
  • Filter element material
  • Polyethylene (PE)
  • Storage temperature
  • RT
MN730681 SPE columns, CHROMABOND Drug, 45 µm, 1 mL/100 mg Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE)
  • Brand
  • CHROMABOND
  • Phase
  • Drug
  • Mode
  • Special application or diverse
  • Base material
  • Silica gel
  • Surface chemistry
  • Special bifunctional modification - C8/SA (octyl phase/strong cation exchanger – benzenesulfonic acid)
  • Column type
  • SPE column
  • Hardware
  • Polypropylene (PP) columns with polyethylene (PE) filter elements
  • Column shape
  • Open tubular syringe-shaped column with Luer tip outlet
  • Column volume
  • 1 mL
  • Filling quantity
  • 100 mg
  • Column volume/adsorbent weight
  • 1 mL/100 mg
  • Recommended application(s)
  • Enrichment of acidic, neutral and basic drugs from urine or plasma
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 45 µm
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • pH stability
  • 2.0–8.0
  • Filter element material
  • Polyethylene (PE)
  • Storage temperature
  • RT
MN732168 SPE LV columns, CHROMABOND Drug, 45 µm, 15 mL/200 mg Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE)
  • Brand
  • CHROMABOND
  • Phase
  • Drug
  • Mode
  • Special application or diverse
  • Base material
  • Silica gel
  • Surface chemistry
  • Special bifunctional modification - C8/SA (octyl phase/strong cation exchanger – benzenesulfonic acid)
  • Column type
  • SPE LV column
  • Hardware
  • Large volume (LV) polypropylene (PP) columns with polyethylene (PE) filter elements
  • Column shape
  • Funnel-shaped reservoir with 15 mL volume
  • Column volume
  • 15 mL
  • Filling quantity
  • 200 mg
  • Column volume/adsorbent weight
  • 15 mL/200 mg
  • Recommended application(s)
  • Enrichment of acidic, neutral and basic drugs from urine or plasma
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 45 µm
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • pH stability
  • 2.0–8.0
  • Filter element material
  • Polyethylene (PE)
  • Storage temperature
  • RT
MN730680 SPE columns, CHROMABOND Drug II, 45 µm, 3 mL/200 mg Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE)
  • Brand
  • CHROMABOND
  • Phase
  • Drug II
  • Mode
  • Special application or diverse
  • Base material
  • Silica gel
  • Surface chemistry
  • Special bifunctional modification - C8/SB (octyl phase/strong anion exchanger – quaternary amine)
  • Column type
  • SPE column
  • Hardware
  • Polypropylene (PP) columns with polyethylene (PE) filter elements
  • Column shape
  • Open tubular syringe-shaped column with Luer tip outlet
  • Column volume
  • 3 mL
  • Filling quantity
  • 200 mg
  • Column volume/adsorbent weight
  • 3 mL/200 mg
  • Recommended application(s)
  • Acidic analytes from biological fluids, Extraction of THC and derivatives from urine, blood, serum, plasma
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 45 µm
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • pH stability
  • 2.0–8.0
  • Filter element material
  • Polyethylene (PE)
  • Storage temperature
  • RT
MN730132 SPE columns, CHROMABOND SA/SiOH, 45 µm, 3 mL/500/500 mg Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE)
  • Brand
  • CHROMABOND
  • Phase
  • SA/SiOH
  • Mode
  • Special application or diverse
  • Base material
  • Silica gel
  • Surface chemistry
  • Special combination phase, SA- silica based benzenesulfonic acid (strongly acidic cation exchanger - SCX) modification, unmodified silica (SiOH)
  • Column type
  • SPE column
  • Hardware
  • Polypropylene (PP) columns with polyethylene (PE) filter elements
  • Column shape
  • Open tubular syringe-shaped column with Luer tip outlet
  • Column volume
  • 3 mL
  • Filling quantity
  • 500/500 mg
  • Column volume/adsorbent weight
  • 3 mL/500/500 mg
  • Selling unit
  • 50 columns, 250 columns
  • Recommended application(s)
  • Extraction of PCBs from waste oil (hexane extract)
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 45 µm
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • pH stability
  • 2.0–8.0
  • Filter element material
  • Polyethylene (PE)
  • Storage temperature
  • RT
MN730931 SPE columns, CHROMABOND HR-X, 85 µm, 3 mL/200 mg Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE)
  • Brand
  • CHROMABOND
  • Phase
  • HR-X
  • Mode
  • Reversed phase (RP)
  • Base material
  • PS/DVB copolymer
  • Surface chemistry
  • Hydrophobic spherical polystyrene-divinylbenzene copolymer (PS/DVB)
  • Column type
  • SPE column
  • Hardware
  • Polypropylene (PP) columns with polyethylene (PE) filter elements
  • Column shape
  • Open tubular syringe-shaped column with Luer tip outlet
  • Column volume
  • 3 mL
  • Filling quantity
  • 200 mg
  • Column volume/adsorbent weight
  • 3 mL/200 mg
  • Selling unit
  • 30 columns, 250 columns
  • Recommended application(s)
  • Active ingredients from tablets, Drugs, Drugs from plasma, Drugs from serum, Drugs from urine, Herbicide, PAHs and PCBs from water, PCB, Pesticides, Pharmaceuticals, Phenols
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 85 µm
  • Particle shape
  • Spherical
  • pH stability
  • 1.0–14.0
  • Filter element material
  • Polyethylene (PE)
  • Storage temperature
  • RT

Overview

Main steps of the SPE procedure

1) Conditioning

Conditioning of the adsorbent is necessary in order to ensure reproducible interaction with the analyte. Conditioning, also called solvation, results in a wetting of the adsorbent and thus produces an environment, which is suitable for adsorption of the analyte. Nonpolar adsorbents are usually conditioned with 2–3 column volumes of a solvent, which is miscible with water (methanol, THF, 2-propanol etc.), followed by the solvent in which the analyte is dissolved (pure matrix, e.g., water, buffer). Polar adsorbents are conditioned with nonpolar solvents. After the conditioning step the adsorbent bed must not run dry, because otherwise solvation is destroyed (deconditioning).


2) Sample application (adsorption)

Sample application can be performed with positive or negative pressure with a flow rate of ~3 mL/min. Sample volumes vary from a few mL up to liters.


3) Washing

Washing of the adsorbent is usually achieved with a special wash solution; however, in some cases it may not be necessary. If the polarity difference between wash solution and eluent is very large, or if both are not miscible, drying of the adsorbent bed after washing is recommended to improve elution and recovery.


4) Elution

Elution with a suitable eluent should not be too fast. The elution speed depends on the column or cartridge dimension and the quantity of adsorbent (about 1 mL/min).


Since analytes can either be adsorbed on the SPE packing material or directly flown through while the interfering substances are retained, two general separation procedures are possible – both cases are shown in the figure below.



Resources