About 30 years ago MACHEREY‑NAGEL designed and introduced CHROMABOND SPE cartridges containing silica-based adsorbents.

SPE is a form of digital (step-wise) chromatography designed to extract, partition, and / or adsorb one or more components from a liquid phase (sample) onto a stationary phase (adsorbent or resin). An adsorbed substance can be removed from the adsorbent by stepwise increase of elution strength of the eluent (step gradient technique).

SPE extends a chromatographic system’s lifetime, improves qualitative and quantitative analysis, and the demand placed on an analytical instrument is considerably lessened.


Catalog No. Product Net Price
MN732960 CHROMABOND Flash BT 4 SiOH cartridges, 40–63 µm, 4 g Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Flash chromatography
  • Brand
  • CHROMABOND
  • Phase
  • SiOH
  • Mode
  • Normal phase (NP)
  • Base material
  • Silica gel
  • Surface chemistry
  • Unmodified silica gel (SiOH)
  • Endcapped
  • No
  • Column type
  • Flash BT
  • Column length
  • 10.6 cm
  • Column inner diameter
  • 12.4 mm
  • Column connection
  • Female Luer lock inlet and male Luer lock outlet
  • Filling material
  • Irregular, 40–63 µm
  • Hardware
  • Polypropylene (PP)
  • Filling quantity
  • 4 g
  • Recommended application(s)
  • Normal phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 40–63 µm
  • Pore size
  • 60 Å
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • Removable closure
  • Removable
  • Typical flow rate
  • 10–50 mL/min
  • pH stability
  • 2.0–8.0
  • Pressure stability (max)
  • 14 bar
  • Filter element material
  • Polyethylene (PE)
  • Scope of delivery
  • 20x CHROMABOND Flash BT cartridges
  • Storage temperature
  • RT
MN732961 CHROMABOND Flash BT 15 SiOH cartridges, 40–63 µm, 15 g Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Flash chromatography
  • Brand
  • CHROMABOND
  • Phase
  • SiOH
  • Mode
  • Normal phase (NP)
  • Base material
  • Silica gel
  • Surface chemistry
  • Unmodified silica gel (SiOH)
  • Endcapped
  • No
  • Column type
  • Flash BT
  • Column length
  • 12.5 cm
  • Column inner diameter
  • 21.2 mm
  • Column connection
  • Female Luer lock inlet and male Luer lock outlet
  • Filling material
  • Irregular, 40–63 µm
  • Hardware
  • Polypropylene (PP)
  • Filling quantity
  • 15 g
  • Recommended application(s)
  • Normal phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 40–63 µm
  • Pore size
  • 60 Å
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • Removable closure
  • Removable
  • Typical flow rate
  • 25–70 mL/min
  • pH stability
  • 2.0–8.0
  • Pressure stability (max)
  • 14 bar
  • Filter element material
  • Polyethylene (PE)
  • Scope of delivery
  • 20x CHROMABOND Flash BT cartridges
  • Storage temperature
  • RT
MN732962 CHROMABOND Flash BT 25 SiOH cartridges, 40–63 µm, 25 g Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Flash chromatography
  • Brand
  • CHROMABOND
  • Phase
  • SiOH
  • Mode
  • Normal phase (NP)
  • Base material
  • Silica gel
  • Surface chemistry
  • Unmodified silica gel (SiOH)
  • Endcapped
  • No
  • Column type
  • Flash BT
  • Column length
  • 17.3 cm
  • Column inner diameter
  • 21.2 mm
  • Column connection
  • Female Luer lock inlet and male Luer lock outlet
  • Filling material
  • Irregular, 40–63 µm
  • Hardware
  • Polypropylene (PP)
  • Filling quantity
  • 25 g
  • Recommended application(s)
  • Normal phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 40–63 µm
  • Pore size
  • 60 Å
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • Removable closure
  • Removable
  • Typical flow rate
  • 25–70 mL/min
  • pH stability
  • 2.0–8.0
  • Pressure stability (max)
  • 14 bar
  • Filter element material
  • Polyethylene (PE)
  • Scope of delivery
  • 15x CHROMABOND Flash BT cartridges
  • Storage temperature
  • RT
MN732963 CHROMABOND Flash BT 40 SiOH cartridges, 40–63 µm, 40 g Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Flash chromatography
  • Brand
  • CHROMABOND
  • Phase
  • SiOH
  • Mode
  • Normal phase (NP)
  • Base material
  • Silica gel
  • Surface chemistry
  • Unmodified silica gel (SiOH)
  • Endcapped
  • No
  • Column type
  • Flash BT
  • Column length
  • 17.6 cm
  • Column inner diameter
  • 26.7 mm
  • Column connection
  • Female Luer lock inlet and male Luer lock outlet
  • Filling material
  • Irregular, 40–63 µm
  • Hardware
  • Polypropylene (PP)
  • Filling quantity
  • 40 g
  • Recommended application(s)
  • Normal phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 40–63 µm
  • Pore size
  • 60 Å
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • Removable closure
  • Removable
  • Typical flow rate
  • 35–80 mL/min
  • pH stability
  • 2.0–8.0
  • Pressure stability (max)
  • 14 bar
  • Filter element material
  • Polyethylene (PE)
  • Scope of delivery
  • 15x CHROMABOND Flash BT cartridges
  • Storage temperature
  • RT
MN732964 CHROMABOND Flash BT 80 SiOH cartridges, 40–63 µm, 80 g Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Flash chromatography
  • Brand
  • CHROMABOND
  • Phase
  • SiOH
  • Mode
  • Normal phase (NP)
  • Base material
  • Silica gel
  • Surface chemistry
  • Unmodified silica gel (SiOH)
  • Endcapped
  • No
  • Column type
  • Flash BT
  • Column length
  • 24.9 cm
  • Column inner diameter
  • 30.9 mm
  • Column connection
  • Female Luer lock inlet and male Luer lock outlet
  • Filling material
  • Irregular, 40–63 µm
  • Hardware
  • Polypropylene (PP)
  • Filling quantity
  • 80 g
  • Recommended application(s)
  • Normal phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 40–63 µm
  • Pore size
  • 60 Å
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • Removable closure
  • Removable
  • Typical flow rate
  • 45–105 mL/min
  • pH stability
  • 2.0–8.0
  • Pressure stability (max)
  • 14 bar
  • Filter element material
  • Polyethylene (PE)
  • Scope of delivery
  • 12x CHROMABOND Flash BT cartridges
  • Storage temperature
  • RT
MN732965 CHROMABOND Flash BT 120 SiOH cartridges, 40–63 µm, 120 g Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Flash chromatography
  • Brand
  • CHROMABOND
  • Phase
  • SiOH
  • Mode
  • Normal phase (NP)
  • Base material
  • Silica gel
  • Surface chemistry
  • Unmodified silica gel (SiOH)
  • Endcapped
  • No
  • Column type
  • Flash BT
  • Column length
  • 26.2 cm
  • Column inner diameter
  • 37.2 mm
  • Column connection
  • Female Luer lock inlet and male Luer lock outlet
  • Filling material
  • Irregular, 40–63 µm
  • Hardware
  • Polypropylene (PP)
  • Filling quantity
  • 120 g
  • Recommended application(s)
  • Normal phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 40–63 µm
  • Pore size
  • 60 Å
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • Removable closure
  • Removable
  • Typical flow rate
  • 55–155 mL/min
  • pH stability
  • 2.0–8.0
  • Pressure stability (max)
  • 14 bar
  • Filter element material
  • Polyethylene (PE)
  • Scope of delivery
  • 10x CHROMABOND Flash BT cartridges
  • Storage temperature
  • RT
MN732966 CHROMABOND Flash BT 200 SiOH cartridges, 40–63 µm, 200 g Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Flash chromatography
  • Brand
  • CHROMABOND
  • Phase
  • SiOH
  • Mode
  • Normal phase (NP)
  • Base material
  • Silica gel
  • Surface chemistry
  • Unmodified silica gel (SiOH)
  • Endcapped
  • No
  • Column type
  • Flash BT
  • Column length
  • 21.6 cm
  • Column inner diameter
  • 59.4 mm
  • Column connection
  • Female Luer lock inlet and male Luer lock outlet
  • Filling material
  • Irregular, 40–63 µm
  • Hardware
  • Polypropylene (PP)
  • Filling quantity
  • 200 g
  • Recommended application(s)
  • Normal phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 40–63 µm
  • Pore size
  • 60 Å
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • Removable closure
  • Removable
  • Typical flow rate
  • 75–225 mL/min
  • pH stability
  • 2.0–8.0
  • Pressure stability (max)
  • 11 bar
  • Filter element material
  • Polyethylene (PE)
  • Scope of delivery
  • 6x CHROMABOND Flash BT cartridges
  • Storage temperature
  • RT
MN732967 CHROMABOND Flash BT 330 SiOH cartridges, 40–63 µm, 330 g Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Flash chromatography
  • Brand
  • CHROMABOND
  • Phase
  • SiOH
  • Mode
  • Normal phase (NP)
  • Base material
  • Silica gel
  • Surface chemistry
  • Unmodified silica gel (SiOH)
  • Endcapped
  • No
  • Column type
  • Flash BT
  • Column length
  • 28.0 cm
  • Column inner diameter
  • 59.8 mm
  • Column connection
  • Female Luer lock inlet and male Luer lock outlet
  • Filling material
  • Irregular, 40–63 µm
  • Hardware
  • Polypropylene (PP)
  • Filling quantity
  • 330 g
  • Recommended application(s)
  • Normal phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 40–63 µm
  • Pore size
  • 60 Å
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • Removable closure
  • Removable
  • Typical flow rate
  • 75–225 mL/min
  • pH stability
  • 2.0–8.0
  • Pressure stability (max)
  • 11 bar
  • Filter element material
  • Polyethylene (PE)
  • Scope of delivery
  • 4x CHROMABOND Flash BT cartridges
  • Storage temperature
  • RT
MN727423 Flash sea sand, acid washed, preignited Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Flash chromatography, accessory
  • Brand
  • CHROMABOND
  • Recommended application(s)
  • Accessories for Flash chromatography (efficient liquid column chromatographic method for preparative applications in the gram range)
  • Scope of delivery
  • 1x 1000 g Flash sea sand
  • Storage temperature
  • RT
MN730076 SPE columns, CHROMABOND SA, 45 µm, 1 mL/100 mg Special offer 
Add to Cart
  • Hazardous material
  • No
  • Method
  • Solid phase extraction (SPE)
  • Brand
  • CHROMABOND
  • Phase
  • SA
  • Mode
  • Ion exchange (IEX)
  • Base material
  • Silica gel
  • Surface chemistry
  • Silica gel with benzenesulfonic acid modification, strongly acidic cation exchanger (SCX)
  • Column type
  • SPE column
  • Hardware
  • Polypropylene (PP) columns with polyethylene (PE) filter elements
  • Column shape
  • Open tubular syringe-shaped column with Luer tip outlet
  • Column volume
  • 1 mL
  • Filling quantity
  • 100 mg
  • Column volume/adsorbent weight
  • 1 mL/100 mg
  • Recommended application(s)
  • Amines, Amino acids, Chlorophyll, PCBs
  • Particle type
  • Fully porous particles (FPP)
  • Particle size
  • 45 µm
  • Particle shape
  • Irregular
  • Specific surface according to BET
  • 500 m²/g
  • pH stability
  • 2.0–8.0
  • Filter element material
  • Polyethylene (PE)
  • Storage temperature
  • RT

Overview

Main steps of the SPE procedure

1) Conditioning

Conditioning of the adsorbent is necessary in order to ensure reproducible interaction with the analyte. Conditioning, also called solvation, results in a wetting of the adsorbent and thus produces an environment, which is suitable for adsorption of the analyte. Nonpolar adsorbents are usually conditioned with 2–3 column volumes of a solvent, which is miscible with water (methanol, THF, 2-propanol etc.), followed by the solvent in which the analyte is dissolved (pure matrix, e.g., water, buffer). Polar adsorbents are conditioned with nonpolar solvents. After the conditioning step the adsorbent bed must not run dry, because otherwise solvation is destroyed (deconditioning).


2) Sample application (adsorption)

Sample application can be performed with positive or negative pressure with a flow rate of ~3 mL/min. Sample volumes vary from a few mL up to liters.


3) Washing

Washing of the adsorbent is usually achieved with a special wash solution; however, in some cases it may not be necessary. If the polarity difference between wash solution and eluent is very large, or if both are not miscible, drying of the adsorbent bed after washing is recommended to improve elution and recovery.


4) Elution

Elution with a suitable eluent should not be too fast. The elution speed depends on the column or cartridge dimension and the quantity of adsorbent (about 1 mL/min).


Since analytes can either be adsorbed on the SPE packing material or directly flown through while the interfering substances are retained, two general separation procedures are possible – both cases are shown in the figure below.



Resources