MN732960
CHROMABOND Flash BT 4 SiOH cartridges, 40–63 µm, 4 g
Special offer
Add to Cart
Hazardous material
No
Method
Flash chromatography
Brand
CHROMABOND
Phase
SiOH
Mode
Normal phase (NP)
Base material
Silica gel
Surface chemistry
Unmodified silica gel (SiOH)
Endcapped
No
Column type
Flash BT
Column length
10.6 cm
Column inner diameter
12.4 mm
Column connection
Female Luer lock inlet and male Luer lock outlet
Filling material
Irregular, 40–63 µm
Hardware
Polypropylene (PP)
Filling quantity
4 g
Recommended application(s)
Normal phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
Particle type
Fully porous particles (FPP)
Particle size
40–63 µm
Pore size
60 Å
Particle shape
Irregular
Specific surface according to BET
500 m²/g
Removable closure
Removable
Typical flow rate
10–50 mL/min
pH stability
2.0–8.0
Pressure stability (max)
14 bar
Filter element material
Polyethylene (PE)
Scope of delivery
20x CHROMABOND Flash BT cartridges
Storage temperature
RT
MN732961
CHROMABOND Flash BT 15 SiOH cartridges, 40–63 µm, 15 g
Special offer
Add to Cart
Hazardous material
No
Method
Flash chromatography
Brand
CHROMABOND
Phase
SiOH
Mode
Normal phase (NP)
Base material
Silica gel
Surface chemistry
Unmodified silica gel (SiOH)
Endcapped
No
Column type
Flash BT
Column length
12.5 cm
Column inner diameter
21.2 mm
Column connection
Female Luer lock inlet and male Luer lock outlet
Filling material
Irregular, 40–63 µm
Hardware
Polypropylene (PP)
Filling quantity
15 g
Recommended application(s)
Normal phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
Particle type
Fully porous particles (FPP)
Particle size
40–63 µm
Pore size
60 Å
Particle shape
Irregular
Specific surface according to BET
500 m²/g
Removable closure
Removable
Typical flow rate
25–70 mL/min
pH stability
2.0–8.0
Pressure stability (max)
14 bar
Filter element material
Polyethylene (PE)
Scope of delivery
20x CHROMABOND Flash BT cartridges
Storage temperature
RT
MN732962
CHROMABOND Flash BT 25 SiOH cartridges, 40–63 µm, 25 g
Special offer
Add to Cart
Hazardous material
No
Method
Flash chromatography
Brand
CHROMABOND
Phase
SiOH
Mode
Normal phase (NP)
Base material
Silica gel
Surface chemistry
Unmodified silica gel (SiOH)
Endcapped
No
Column type
Flash BT
Column length
17.3 cm
Column inner diameter
21.2 mm
Column connection
Female Luer lock inlet and male Luer lock outlet
Filling material
Irregular, 40–63 µm
Hardware
Polypropylene (PP)
Filling quantity
25 g
Recommended application(s)
Normal phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
Particle type
Fully porous particles (FPP)
Particle size
40–63 µm
Pore size
60 Å
Particle shape
Irregular
Specific surface according to BET
500 m²/g
Removable closure
Removable
Typical flow rate
25–70 mL/min
pH stability
2.0–8.0
Pressure stability (max)
14 bar
Filter element material
Polyethylene (PE)
Scope of delivery
15x CHROMABOND Flash BT cartridges
Storage temperature
RT
MN732963
CHROMABOND Flash BT 40 SiOH cartridges, 40–63 µm, 40 g
Special offer
Add to Cart
Hazardous material
No
Method
Flash chromatography
Brand
CHROMABOND
Phase
SiOH
Mode
Normal phase (NP)
Base material
Silica gel
Surface chemistry
Unmodified silica gel (SiOH)
Endcapped
No
Column type
Flash BT
Column length
17.6 cm
Column inner diameter
26.7 mm
Column connection
Female Luer lock inlet and male Luer lock outlet
Filling material
Irregular, 40–63 µm
Hardware
Polypropylene (PP)
Filling quantity
40 g
Recommended application(s)
Normal phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
Particle type
Fully porous particles (FPP)
Particle size
40–63 µm
Pore size
60 Å
Particle shape
Irregular
Specific surface according to BET
500 m²/g
Removable closure
Removable
Typical flow rate
35–80 mL/min
pH stability
2.0–8.0
Pressure stability (max)
14 bar
Filter element material
Polyethylene (PE)
Scope of delivery
15x CHROMABOND Flash BT cartridges
Storage temperature
RT
MN732964
CHROMABOND Flash BT 80 SiOH cartridges, 40–63 µm, 80 g
Special offer
Add to Cart
Hazardous material
No
Method
Flash chromatography
Brand
CHROMABOND
Phase
SiOH
Mode
Normal phase (NP)
Base material
Silica gel
Surface chemistry
Unmodified silica gel (SiOH)
Endcapped
No
Column type
Flash BT
Column length
24.9 cm
Column inner diameter
30.9 mm
Column connection
Female Luer lock inlet and male Luer lock outlet
Filling material
Irregular, 40–63 µm
Hardware
Polypropylene (PP)
Filling quantity
80 g
Recommended application(s)
Normal phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
Particle type
Fully porous particles (FPP)
Particle size
40–63 µm
Pore size
60 Å
Particle shape
Irregular
Specific surface according to BET
500 m²/g
Removable closure
Removable
Typical flow rate
45–105 mL/min
pH stability
2.0–8.0
Pressure stability (max)
14 bar
Filter element material
Polyethylene (PE)
Scope of delivery
12x CHROMABOND Flash BT cartridges
Storage temperature
RT
MN732965
CHROMABOND Flash BT 120 SiOH cartridges, 40–63 µm, 120 g
Special offer
Add to Cart
Hazardous material
No
Method
Flash chromatography
Brand
CHROMABOND
Phase
SiOH
Mode
Normal phase (NP)
Base material
Silica gel
Surface chemistry
Unmodified silica gel (SiOH)
Endcapped
No
Column type
Flash BT
Column length
26.2 cm
Column inner diameter
37.2 mm
Column connection
Female Luer lock inlet and male Luer lock outlet
Filling material
Irregular, 40–63 µm
Hardware
Polypropylene (PP)
Filling quantity
120 g
Recommended application(s)
Normal phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
Particle type
Fully porous particles (FPP)
Particle size
40–63 µm
Pore size
60 Å
Particle shape
Irregular
Specific surface according to BET
500 m²/g
Removable closure
Removable
Typical flow rate
55–155 mL/min
pH stability
2.0–8.0
Pressure stability (max)
14 bar
Filter element material
Polyethylene (PE)
Scope of delivery
10x CHROMABOND Flash BT cartridges
Storage temperature
RT
MN732966
CHROMABOND Flash BT 200 SiOH cartridges, 40–63 µm, 200 g
Special offer
Add to Cart
Hazardous material
No
Method
Flash chromatography
Brand
CHROMABOND
Phase
SiOH
Mode
Normal phase (NP)
Base material
Silica gel
Surface chemistry
Unmodified silica gel (SiOH)
Endcapped
No
Column type
Flash BT
Column length
21.6 cm
Column inner diameter
59.4 mm
Column connection
Female Luer lock inlet and male Luer lock outlet
Filling material
Irregular, 40–63 µm
Hardware
Polypropylene (PP)
Filling quantity
200 g
Recommended application(s)
Normal phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
Particle type
Fully porous particles (FPP)
Particle size
40–63 µm
Pore size
60 Å
Particle shape
Irregular
Specific surface according to BET
500 m²/g
Removable closure
Removable
Typical flow rate
75–225 mL/min
pH stability
2.0–8.0
Pressure stability (max)
11 bar
Filter element material
Polyethylene (PE)
Scope of delivery
6x CHROMABOND Flash BT cartridges
Storage temperature
RT
MN732967
CHROMABOND Flash BT 330 SiOH cartridges, 40–63 µm, 330 g
Special offer
Add to Cart
Hazardous material
No
Method
Flash chromatography
Brand
CHROMABOND
Phase
SiOH
Mode
Normal phase (NP)
Base material
Silica gel
Surface chemistry
Unmodified silica gel (SiOH)
Endcapped
No
Column type
Flash BT
Column length
28.0 cm
Column inner diameter
59.8 mm
Column connection
Female Luer lock inlet and male Luer lock outlet
Filling material
Irregular, 40–63 µm
Hardware
Polypropylene (PP)
Filling quantity
330 g
Recommended application(s)
Normal phase Flash chromatography applications (efficient liquid column chromatographic method for preparative applications in the gram range)
Particle type
Fully porous particles (FPP)
Particle size
40–63 µm
Pore size
60 Å
Particle shape
Irregular
Specific surface according to BET
500 m²/g
Removable closure
Removable
Typical flow rate
75–225 mL/min
pH stability
2.0–8.0
Pressure stability (max)
11 bar
Filter element material
Polyethylene (PE)
Scope of delivery
4x CHROMABOND Flash BT cartridges
Storage temperature
RT
MN727423
Flash sea sand, acid washed, preignited
Special offer
Add to Cart
Hazardous material
No
Method
Flash chromatography, accessory
Brand
CHROMABOND
Recommended application(s)
Accessories for Flash chromatography (efficient liquid column chromatographic method for preparative applications in the gram range)
Scope of delivery
1x 1000 g Flash sea sand
Storage temperature
RT
MN730076
SPE columns, CHROMABOND SA, 45 µm, 1 mL/100 mg
Special offer
Add to Cart
Hazardous material
No
Method
Solid phase extraction (SPE)
Brand
CHROMABOND
Phase
SA
Mode
Ion exchange (IEX)
Base material
Silica gel
Surface chemistry
Silica gel with benzenesulfonic acid modification, strongly acidic cation exchanger (SCX)
Column type
SPE column
Hardware
Polypropylene (PP) columns with polyethylene (PE) filter elements
Column shape
Open tubular syringe-shaped column with Luer tip outlet
Column volume
1 mL
Filling quantity
100 mg
Column volume/adsorbent weight
1 mL/100 mg
Recommended application(s)
Amines, Amino acids, Chlorophyll, PCBs
Particle type
Fully porous particles (FPP)
Particle size
45 µm
Particle shape
Irregular
Specific surface according to BET
500 m²/g
pH stability
2.0–8.0
Filter element material
Polyethylene (PE)
Storage temperature
RT