Agilent Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is available in single quadrupole and triple quadrupole configurations. Our single quadrupole ICP-MS address the range of typical ICP-MS measurements from routine, regulated analysis to advanced research and demanding applications. Our triple quadrupole ICP-MS will give you the confidence of knowing you can resolve problematic interferences – even in your most difficult samples – delivering results you know you can trust.

Catalog No. Product Net Price
AGIL2010106800 Nebulizer, K-style (Conikal) concentric, glass, recommended for routine analysis of organic solvents and samples with up to 5% dissolved solids. Replacement nebulizer supplied with Conikal sample introduction kit (pn G8007AA #012). Recommended for routine 697 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Chemical Compatibility
  • Aqueous Aromatic organics Ketone solvents
  • Gas Connector
  • Ezylok
  • Material
  • Borosilicate glass
  • Name
  • Conikal
  • Nebulizer Sample Particle Size Tolerance
  • 75 µm
  • Notes
  • Routine analysis of organic solvents and samples to 5 % TDS
  • Other Features
  • Suitable for use with AVS/SVS
  • Sample Connection
  • EzyFit
  • Sample Uptake Rate
  • 2
  • Self Aspirating
  • Yes
  • TDS Handling Capability
  • 5 % TDS
  • Type
  • Concentric
AGIL2010106800 Nebulizer, K-style (Conikal) concentric, glass, recommended for routine analysis of organic solvents and samples with up to 5% dissolved solids. Replacement nebulizer supplied with Conikal sample introduction kit (pn G8007AA #012). Recommended for routine 697 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Chemical Compatibility
  • Aqueous Aromatic organics Ketone solvents
  • Gas Connector
  • Ezylok
  • Material
  • Borosilicate glass
  • Name
  • Conikal
  • Nebulizer Sample Particle Size Tolerance
  • 75 µm
  • Notes
  • Routine analysis of organic solvents and samples to 5 % TDS
  • Other Features
  • Suitable for use with AVS/SVS
  • Sample Connection
  • EzyFit
  • Sample Uptake Rate
  • 2
  • Self Aspirating
  • Yes
  • TDS Handling Capability
  • 5 % TDS
  • Type
  • Concentric
G8010-60293 OneNeb series 2 inert concentric nebulizer. Recommended for routine analysis of samples up to 25% TDS; inert construction makes it suitable for most solution types. Includes replaceable sample capillary/connector assembly, quick release connector for nebu 948 
Add to Cart
  • UNSPSC Code
  • 41113000
  • Chemical Compatibility
  • Aqueous HF acid Organic solvents
  • Compatible with Advanced Valve System (AVS)
  • No
  • Gas Connector
  • Quick release
  • Material
  • PEEK
  • Name
  • OneNeb
  • Nebulizer Sample Particle Size Tolerance
  • 150 µm
  • Notes
  • Ideal for routine analysis of samples up to 25 % TDS with good precision and better sensitivity than a SeaSpray; inert construction makes it suitable for most solution types
  • Other Features
  • Not suitable for use with SVS/AVS
  • Sample Connection
  • Direct
  • Self Aspirating
  • No
  • TDS Handling Capability
  • 25 % TDS
  • Type
  • Flow-blurring
G1833-65088 Obsolete. No replacement recommendation. Screw set for reaction cell in Agilent 7500c. Special offer 
Add to Cart
  • UNSPSC Code
  • 41115411
G1833-65133 Octopole assembly, without cell entrance/exit, QP focus, or O-ring for 7500 ICP-MS, models 7500cs, 7500ce, and 7500cx 1083 
Add to Cart
  • UNSPSC Code
  • 41115411
G1833-65408 Skimmer base, brass, standard for Agilent 7500s, optional for 7500a and 7500i. Use with platinum skimmer cone. Includes screws 264 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Base Material
  • Brass
  • Cone Type
  • Base
G1833-65498 Skimmer base, stainless steel, standard for Agilent 7500c ICP-MS. Use with nickel skimmer cone. Includes screws 383 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Base Material
  • Stainless steel
  • Cone Type
  • Base
G1833-65503 Obsolete. No replacement recommendation. Octopole assembly, Agilent 7500c ICP-MS. Includes cell entrance/exit without O-ring. Special offer 
Add to Cart
  • UNSPSC Code
  • 41115411
G1833-65505 Skimmer base, brass, optional for Agilent 7500c ICP-MS. Use with platinum skimmer cone. Includes screws Special offer 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Base Material
  • Brass
  • Cone Type
  • Base
G1833-66000 Obsolete. No replacement recommendation. Cell Exit Lens for 7500cs Special offer 
Add to Cart
  • UNSPSC Code
  • 41115411

Overview

ICP-MS system operates with an ICP-MS Nebulizer, in which a high velocity Argon gas stream meets a liquid stream causing filmwise breakup of the solution into a fine aerosol. The aerosol particle size should ideally be sub-10µm with a narrow particle size distribution to achieve efficient atomization and ionization. Agilent offers a comprehensive range of ICP-MS nebulizers and supplies to solve any ICP-MS analysis challenge.

The portfolio includes standard glass concentric nebulizer (MicroMist), quartz and inert PFA nebulizers (MicroFlow and C-Flow), as well as robust Mira Mist PEEK or PTFE for high TDS samples and low-flow self-aspirating or total consumption nebulizers for your clinical or limited volume samples. ICP-MS nebulizer support is provided with a full range of accessories for all models including nebulizer cleaning tools.


The ICP torch is used to form, shape, and sustain an argon plasma which atomizes and ionizes the sample aerosol. Agilent ICP-MS Torches with Shield Torch System (STS) provide precise ion energy control, ensuring high sensitivity and stability, even in cool plasma mode for effective interference removal (ArO+).

Our portfolio is comprised of a wide range of ICP torches for your specific ICP-MS configuration. One-piece quartz torches offer the best stability and ease of use. The large 2.5mm injector on the standard torch gives maximum robustness and lowest matrix interferences for the best plasma stability. Single-piece torches with narrow bore injectors (1.0mm or 1.5 mm) are designed for use with organic solvents, to reduce plasma loading and improve plasma stability. Optional semi-demountable quartz torches with removable platinum or sapphire injectors are also available for use with the PFA inert sample introduction kit.