+852-3069 6950
css@gugent.com.hk
 

Agilent Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is available in single quadrupole and triple quadrupole configurations. Our single quadrupole ICP-MS address the range of typical ICP-MS measurements from routine, regulated analysis to advanced research and demanding applications. Our triple quadrupole ICP-MS will give you the confidence of knowing you can resolve problematic interferences – even in your most difficult samples – delivering results you know you can trust.

Catalog No. Product Net Price
AGIL8003-0493 PerkinElmer, Sample inlet (UniFit) fitting, 0.75 mm id, 700 mm, for U-series concentric glass nebulizer. Suitable for ELAN 9000/6xX00/DRC and NexION 69 
Add to Cart
  • Inner Diameter (ID)
  • 0.75 mm
  • Length
  • 700 mm
  • UNSPSC Code
  • 41122000
  • Where Used
  • Nebulizer
AGIL8003-0493 PerkinElmer, Sample inlet (UniFit) fitting, 0.75 mm id, 700 mm, for U-series concentric glass nebulizer. Suitable for ELAN 9000/6xX00/DRC and NexION 69 
Add to Cart
  • Inner Diameter (ID)
  • 0.75 mm
  • Length
  • 700 mm
  • UNSPSC Code
  • 41122000
  • Where Used
  • Nebulizer
AGIL8003-0495 PerkinElmer, Clip, nebulizer pressure hose, 10/pk. Suitable for ELAN 9000/6xX00/DRC and NexION 27 
Add to Cart
  • UNSPSC Code
  • 41122000
  • Where Used
  • Nebulizer
AGIL8003-0500 Nebulizer, OpalMist PFA, 0.4 mL/min, concentric, suitable for PerkinElmer ICP-MS. Sample uptake 0.4 mL/min, for high-precision analyses requiring high chemical resistance to HF, alkalis, and organics, and trace analyses, for ELAN 9000/6xX00/DRC/NexION 1439 
Add to Cart
  • UNSPSC Code
  • 41122000
  • Chemical Compatibility
  • Aqueous HF acid Organic solvents Strong acids
  • Gas Connector
  • Quick release
  • Material
  • PFA
  • Sample Uptake Rate
  • 400
  • Self Aspirating
  • Yes
  • TDS Handling Capability
  • 15 %TDS
AGIL8003-0502 PerkinElmer, Fitting, male barb, chlorotrifluoroethylene CTFE, for sample inlet fitting used with type A/C/K nebulizers. Suitable for ELAN 9000/6xX00/DRC and NexION 66 
Add to Cart
  • UNSPSC Code
  • 41122000
  • Where Used
  • Nebulizer
AGIL8003-0504 PerkinElmer ICP-MS Sample capillary, PTFE, 0.020 inch id, 0.062 inch od, for sample inlet fitting used with type A/C/K nebulizers. For use with Elan / NexION 9 
Add to Cart
  • UNSPSC Code
  • 41122000
AGIL8003-0505 Nebulizer, PFA-ST, ultraclean, flow rate 100-400 µL/min, suitable for PerkinElmer ICP-MS. Includes exchangeable capillaries to provide flow rates from 100-400 µL/min 1522 
Add to Cart
  • UNSPSC Code
  • 41122000
  • Chemical Compatibility
  • Aqueous HF acid Organic solvents Strong acids
  • Material
  • PFA
  • Sample Uptake Rate
  • 400
  • Self Aspirating
  • Yes
  • Type
  • Concentric
AGIL8003-0506 PerkinElmer, Union, Chlorotrifluoroethylene CTFE, for PFA-ST nebulizer, connects to ultraclean sampler probe. Suitable for ELAN 9000/6xX00/DRC and NexION 92 
Add to Cart
  • UNSPSC Code
  • 41122000
  • Where Used
  • Nebulizer
AGIL8003-0507 Nebulizer, PFA-ST, microflow, inert high TDS, suitable for PerkinElmer ICP-MS. High performance, clog resistant, chemically inert, for ELAN 9000/6xX00/DRC/NexION 1931 
Add to Cart
  • UNSPSC Code
  • 41122000
  • Chemical Compatibility
  • Aqueous HF acid Organic solvents Strong acids
  • Material
  • PFA
  • Self Aspirating
  • Yes
  • Type
  • Concentric
AGIL8003-0508 PerkinElmer ICP-MS Obstruction removal set, for PFA nebulizers 128 
Add to Cart
  • UNSPSC Code
  • 41122000

Overview

ICP-MS system operates with an ICP-MS Nebulizer, in which a high velocity Argon gas stream meets a liquid stream causing filmwise breakup of the solution into a fine aerosol. The aerosol particle size should ideally be sub-10µm with a narrow particle size distribution to achieve efficient atomization and ionization. Agilent offers a comprehensive range of ICP-MS nebulizers and supplies to solve any ICP-MS analysis challenge.

The portfolio includes standard glass concentric nebulizer (MicroMist), quartz and inert PFA nebulizers (MicroFlow and C-Flow), as well as robust Mira Mist PEEK or PTFE for high TDS samples and low-flow self-aspirating or total consumption nebulizers for your clinical or limited volume samples. ICP-MS nebulizer support is provided with a full range of accessories for all models including nebulizer cleaning tools.


The ICP torch is used to form, shape, and sustain an argon plasma which atomizes and ionizes the sample aerosol. Agilent ICP-MS Torches with Shield Torch System (STS) provide precise ion energy control, ensuring high sensitivity and stability, even in cool plasma mode for effective interference removal (ArO+).

Our portfolio is comprised of a wide range of ICP torches for your specific ICP-MS configuration. One-piece quartz torches offer the best stability and ease of use. The large 2.5mm injector on the standard torch gives maximum robustness and lowest matrix interferences for the best plasma stability. Single-piece torches with narrow bore injectors (1.0mm or 1.5 mm) are designed for use with organic solvents, to reduce plasma loading and improve plasma stability. Optional semi-demountable quartz torches with removable platinum or sapphire injectors are also available for use with the PFA inert sample introduction kit.


Resources