+852-3069 6950
css@gugent.com.hk
 

Agilent Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is available in single quadrupole and triple quadrupole configurations. Our single quadrupole ICP-MS address the range of typical ICP-MS measurements from routine, regulated analysis to advanced research and demanding applications. Our triple quadrupole ICP-MS will give you the confidence of knowing you can resolve problematic interferences – even in your most difficult samples – delivering results you know you can trust.

Catalog No. Product Net Price
G8400-60700 Replacement Argon humidifier, two gas lines, for Agilent ICP-MS. Includes bottle, cap and membrane tube. Tubing kit (G8400-60710) and bracket for attachment to ICP-MS not included. Humidifies nebulizer gas when analyzing high total dissolved solids (TDS 1596 
Add to Cart
  • UNSPSC Code
  • 41113000
G8400-60710 Tubing set, for argon humidifier, for Agilent ICP-MS,ICP-OES and MP-AES. Includes tubing, black, PTFE, 2 x 4 mm, 615 mm long (5043-0059), tubing, black, PTFE, 1.59 x 3.17 mm, 575 mm long (5043-0060). Used with ICP-MS (G8400-60700), ICP-OES and MP-AES (G80 147 
Add to Cart
  • UNSPSC Code
  • 40183000
G3286-80210 Y-axis sensor, used with series ASX-500 ICP-MS autosampler systems 507 
Add to Cart
  • UNSPSC Code
  • 41115411
G3286-80211 X-axis sensor, used with series ASX-500 ICP-MS autosampler systems 632 
Add to Cart
  • UNSPSC Code
  • 41115411
G3286-80217 X-axis lead screw kit, used with series ASX-500 ICP-MS autosampler systems 1890 
Add to Cart
  • UNSPSC Code
  • 41115411
AGIL6610030600 Calibration Mix 2 for AA and ICP-OES. 100 mg/L Ag, Al, As, Ba, Be, Cd, Co, Cr, Cu, Mn, Ni, Pb, Se, Tl, Th, U, V and Zn Special offer 
Add to Cart
  • Format
  • Multi component mixture
  • UNSPSC Code
  • 41116107
  • Analyte Count
  • 18
  • Chemical Type
  • Inorganic
  • Packaging
  • Bottle
  • Part Number Application
  • Multi Element
  • Part Number Application Domain
  • Elemental Analysis
  • Quality Standard
  • ISO 17034
  • Solvent
  • 5% Nitric acid
  • Technique
  • Atomic Absorption ICP-OES
  • Volume
  • 125 mL
AGIL5190-7001 Calibration blank solution 5% HNO3 for ICP-OES, MP-AES, and AA 105 
Add to Cart
  • UNSPSC Code
  • 41116105
  • Analyte Count
  • 1
  • Chemical Type
  • Inorganic
  • Packaging
  • Bottle
  • Part Number Application
  • Multi Element
  • Part Number Application Domain
  • Elemental Analysis
  • Quality Standard
  • ISO 17034
  • Solvent
  • 5% Nitric acid
  • Technique
  • Atomic Absorption ICP-MS ICP-OES
  • Volume
  • 500 mL
G8410-80105 SPS 4 probe suits SPS 4 microtiter tray. Required when using the SPS4 autosampler with microtiter tray for sampling from a 96 position wellplate. Requires, but does not include the well plate tray adapter kit (p/n G8410-40003) or any compatible well plate 325 
Add to Cart
  • Inner Diameter (ID)
  • 0.25 mm
  • UNSPSC Code
  • 41113000
  • Autosampler Compatibility
  • SPS 4
  • Component Type
  • Probe
AGIL3710033700 Joining tube, PVC, 0.030 inch id. Sample inlet tubing, for concentric glass nebulizer used with Liberty Series ICP-OES 16 
Add to Cart
  • Inner Diameter (ID)
  • 0.76 mm
  • UNSPSC Code
  • 41113000
  • Outer Diameter (OD)
  • 2.44 mm
  • Where Used
  • Nebulizer
AGIL3710049000 Peristaltic pump tubing, PVC Solvaflex 3-bridged, gray/gray tabs, for SPS 3 autosampler when pumping acidic or aqueous rinses, 12/pk 76 
Add to Cart
  • Inner Diameter (ID)
  • 1.3 mm
  • Length
  • 455 mm
  • UNSPSC Code
  • 40142600
  • Chemical Compatibility
  • Aqueous Aromatic organics HF acid
  • Flared
  • No
  • Number of Stops
  • 3
  • Stop Color
  • Gray/Gray/Gray
  • Tubing Material
  • Solvaflex

Overview

ICP-MS system operates with an ICP-MS Nebulizer, in which a high velocity Argon gas stream meets a liquid stream causing filmwise breakup of the solution into a fine aerosol. The aerosol particle size should ideally be sub-10µm with a narrow particle size distribution to achieve efficient atomization and ionization. Agilent offers a comprehensive range of ICP-MS nebulizers and supplies to solve any ICP-MS analysis challenge.

The portfolio includes standard glass concentric nebulizer (MicroMist), quartz and inert PFA nebulizers (MicroFlow and C-Flow), as well as robust Mira Mist PEEK or PTFE for high TDS samples and low-flow self-aspirating or total consumption nebulizers for your clinical or limited volume samples. ICP-MS nebulizer support is provided with a full range of accessories for all models including nebulizer cleaning tools.


The ICP torch is used to form, shape, and sustain an argon plasma which atomizes and ionizes the sample aerosol. Agilent ICP-MS Torches with Shield Torch System (STS) provide precise ion energy control, ensuring high sensitivity and stability, even in cool plasma mode for effective interference removal (ArO+).

Our portfolio is comprised of a wide range of ICP torches for your specific ICP-MS configuration. One-piece quartz torches offer the best stability and ease of use. The large 2.5mm injector on the standard torch gives maximum robustness and lowest matrix interferences for the best plasma stability. Single-piece torches with narrow bore injectors (1.0mm or 1.5 mm) are designed for use with organic solvents, to reduce plasma loading and improve plasma stability. Optional semi-demountable quartz torches with removable platinum or sapphire injectors are also available for use with the PFA inert sample introduction kit.


Resources