+852-3069 6950
css@gugent.com.hk
 

Agilent Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is available in single quadrupole and triple quadrupole configurations. Our single quadrupole ICP-MS address the range of typical ICP-MS measurements from routine, regulated analysis to advanced research and demanding applications. Our triple quadrupole ICP-MS will give you the confidence of knowing you can resolve problematic interferences – even in your most difficult samples – delivering results you know you can trust.

Catalog No. Product Net Price
G3666-60503 Extraction lens 2 for m-lens of Agilent 7900 and 8900 Semiconductor ICP-MS 720 
Add to Cart
  • UNSPSC Code
  • 41113000
  • Lens Type
  • M
G3666-67044 Screw, spacer and O-ring kit for ORS cell, for 8900 without axial accelerator. Suitable for Agilent 8900 ICP-MS standard model without axial acceleration (not advanced or semiconductor model) 490 
Add to Cart
  • UNSPSC Code
  • 41113000
  • Notes
  • 7700x/s/e and 8800 series
  • Where Used
  • ORS cell
G3666-67046 Octopole assembly, without axial accelerator, for Agilent 8900 ICP-MS. For 8900 standard x-lens model for routine applications, G3665A without #100 or #200 1240 
Add to Cart
  • UNSPSC Code
  • 41113000
G3666-67141 ORS cell assembly, with axial accelerator, for Agilent 8900 ICP-MS. For 8900 advanced application x-lens and semiconductor s-lens models, G3665A with #100 or #200 4387 
Add to Cart
  • UNSPSC Code
  • 41113000
G3154-65002 Guard Column for arsenic Speciation. Use with G3154-65001 or G3288-80000 speciation columns for arsenic 1172 
Add to Cart
  • UNSPSC Code
  • 41115411
G8010-68004 Volatile organic sample introduction kit for Agilent 5000 series RV ICP-OES. Includes Conikal nebulizer, glass, U-series (p/n G8010-60270), Easy-fit fully demountable torch, with organics outer tube-set and 0.8mm id injector (p/n G8020-68001), sample and 3134 
Add to Cart
  • UNSPSC Code
  • 41113000
  • Notes
  • Conikal nebulizer, demountable Easy-fit torch with 0.8 mm id injector, solvent resistant drain tubing and FPM peristaltic pump tubes for sample (white/white tabs) and waste (blue/blue tabs). Requires but does NOT include a cooled spray chamber. The IsoMist peltier cooled spray chamber is recommended.
G8010-68005 Volatile organic sample introduction kit for Agilent 5000 series Dual View (VDV/SVDV) ICP-OES. Includes white/white FPM sample pump tubes (p/n 3710043700), blue/blue FPM waste pump tubes (p/n 3710043900), solvent resistant drain tubing (p/n 3710035400), C 3134 
Add to Cart
  • UNSPSC Code
  • 41113000
  • Notes
  • Conikal nebulizer, demountable Easy-fit torch with 0.8 mm id injector, solvent resistant drain tubing and FPM peristaltic pump tubes for sample (white/white tabs) and waste (blue/blue tabs). Requires but does NOT include a cooled spray chamber. The IsoMist peltier cooled spray chamber is recommended.
G8010-68007 Sample introduction kit, inert, for HF digests, for Agilent 5000 series Dual View (VDV/SVDV) ICP-OES. Includes inert double-pass spray chamber with removable baffle (p/n G8014-68002), OneNeb 2 nebulizer (p/n G8010-60293), Semi-demountable inert torch wih 3519 
Add to Cart
  • UNSPSC Code
  • 41113000
  • Notes
  • Inert double-pass spray chamber with ball joint socket, OneNeb nebulizer, inert demountable Easy-fit torch with ceramic injector (1.8 mm id), torch clamp for inert torch and Solvaflex peristaltic pump tubes for sample (black/black tabs) and waste (gray/gray tabs)
G8010-68008 Ketone-based organics sample introduction kit for Agilent 5000 series RV ICP-OES. Includes double-pass spray chamber, cyclonic, glass (p/n G8010-60256), Conikal nebulizer, glass, U-series (p/n G8010-60270), Easy-fit torch semi-demountable 1.4 mm injector 3609 
Add to Cart
  • UNSPSC Code
  • 41113000
  • Notes
  • Double-pass glass cyclonic spray chamber with ball joint socket, Conikal nebulizer, demountable Easy-fit torch with 1.4 mm id injector, solvent resistant drain tubing and Marprene peristaltic pump tubes for sample (white/white tabs) and waste (blue/blue tabs)
G8010-68009 Ketone solvent sample introduction kit for Agilent 5000 series Dual View (VDV/SVD) ICP-OES. Includes double-pass spray chamber, cyclonic, glass (p/n G8010-60256), Conikal nebulizer, glass, U-series (p/n G8010-60270), Easy-fit fully demountable torch with 3609 
Add to Cart
  • UNSPSC Code
  • 41113000
  • Notes
  • Double-pass glass cyclonic spray chamber with ball joint socket, Conikal nebulizer, demountable Easy-fit torch with 1.4 mm id injector, solvent resistant drain tubing and Marprene peristaltic pump tubes for sample (white/white tabs) and waste (blue/blue tabs)

Overview

ICP-MS system operates with an ICP-MS Nebulizer, in which a high velocity Argon gas stream meets a liquid stream causing filmwise breakup of the solution into a fine aerosol. The aerosol particle size should ideally be sub-10µm with a narrow particle size distribution to achieve efficient atomization and ionization. Agilent offers a comprehensive range of ICP-MS nebulizers and supplies to solve any ICP-MS analysis challenge.

The portfolio includes standard glass concentric nebulizer (MicroMist), quartz and inert PFA nebulizers (MicroFlow and C-Flow), as well as robust Mira Mist PEEK or PTFE for high TDS samples and low-flow self-aspirating or total consumption nebulizers for your clinical or limited volume samples. ICP-MS nebulizer support is provided with a full range of accessories for all models including nebulizer cleaning tools.


The ICP torch is used to form, shape, and sustain an argon plasma which atomizes and ionizes the sample aerosol. Agilent ICP-MS Torches with Shield Torch System (STS) provide precise ion energy control, ensuring high sensitivity and stability, even in cool plasma mode for effective interference removal (ArO+).

Our portfolio is comprised of a wide range of ICP torches for your specific ICP-MS configuration. One-piece quartz torches offer the best stability and ease of use. The large 2.5mm injector on the standard torch gives maximum robustness and lowest matrix interferences for the best plasma stability. Single-piece torches with narrow bore injectors (1.0mm or 1.5 mm) are designed for use with organic solvents, to reduce plasma loading and improve plasma stability. Optional semi-demountable quartz torches with removable platinum or sapphire injectors are also available for use with the PFA inert sample introduction kit.


Resources