Agilent Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is available in single quadrupole and triple quadrupole configurations. Our single quadrupole ICP-MS address the range of typical ICP-MS measurements from routine, regulated analysis to advanced research and demanding applications. Our triple quadrupole ICP-MS will give you the confidence of knowing you can resolve problematic interferences – even in your most difficult samples – delivering results you know you can trust.

Catalog No. Product Net Price
G8000-70002 Easy-fit torch, for Agilent 4100 MP-AES. Features a 1.2mm ID injector with a ball joint base for easy connection to the spray chamber (the standard torch) 755 
Add to Cart
  • UNSPSC Code
  • 41115406
  • Chemical Compatibility
  • Aqueous Aromatic organics Ketone solvents
  • Type
  • Aqueous
G8003-20011 Ball joint adaptor, PTFE, for Agilent 4200 MP-AES inert torch 82 
Add to Cart
  • UNSPSC Code
  • 41113000
G8003-68003 Torch cleaning stand, for cleaning Easy-fit MP-AES torches, for 4100/4200 MP-AES. This stand is designed to make the torch cleaning process easier and safer. It provides a stable platform that allows either the whole torch or the injector/base assembly to 125 
Add to Cart
  • UNSPSC Code
  • 41113000
G8010-67001 Operating supplies kit for Agilent 5000 series Dual View (DV/SVDV) ICP-OES. Operating supplies kit for 1-year use of Agilent 5000 series DV ICP-OES. Includes 1.8mm ID EasyFit semi-demountable torch (p/n G8010-60236), 2 quartz outer tube sets (p/n G8010-60 4780 
Add to Cart
  • UNSPSC Code
  • 41113000
  • Notes
  • Includes Easy Fit demountable torch with 1.8 mm injector, quartz outer tube set (2), PVC peristaltic pump tubing with white/white tabs for sample (2 x 12/pk), PVC peristaltic pump tubing with blue/blue tabs for waste (4 x 12/pk), internal standard pump tubing & connectors, U-series SeaSpray nebulizer, UniFit sample inlet fittings (0.75 mm id), EzyLok gas connectors for nebulizer, double pass spray chamber with Helix fitting, UniFit connectors for spray chamber drain, clamp for the torch ball joint socket, pre-optic window for axial view, washer for the axial view pre-optic window, O-ring for the axial view pre-optic window, pre-optic window for radial view, washer for the radial view pre-optic window, barb connector 1/16 inch id to 1/8 inch id (2), nebulizer capillary tubing (2 m), PFA tubing for nebulizer gas supply (0.5 m), drain tubing for waste liquid from spray chamber (2 m), drain tubing for sample tray (1.5 m) and Helix seal for spray chamber.
G8012-67001 Operating supplies kit for Agilent 5000 series Radial View ICP-OES. Operating supplies kit for 1-year use of Agilent 5000 series RV ICP-OES. Includes 1.4mm ID EasyFit semi-demountable torch (p/n G8010-60237), 2 quartz outer tube sets (p/n G8010-60263), 4 4521 
Add to Cart
  • UNSPSC Code
  • 41113000
G8010-60227 Clamp for ball joint connector between spray chamber and inert torch, for Agilent MP-AES. Ensures gas-tight seal on ball joint connector, suitable for use with inert torch. 82 
Add to Cart
  • UNSPSC Code
  • 41113000
G8010-60228 Easy-fit 1.8mm torch one piece for 5000 Series VDV/SVDV ICP-OES. Features a 1.8mm ID injector with extended outer tube with slot for radial viewing. This is the standard torch for 5000 Series VDV/SVDV instruments. 762 
Add to Cart
  • UNSPSC Code
  • 41113000
  • Chemical Compatibility
  • Aqueous
  • Type
  • Aqueous
G8010-60232 Easy-fit 2.4mm semi-demountable high solids torch for 5000 series VDV/SVDV ICP-OES. Features a 2.4mm ID injector with replaceable extended outer tube with slot for radial viewing. Recommended for high TDS samples. 785 
Add to Cart
  • UNSPSC Code
  • 41113000
  • Chemical Compatibility
  • Aqueous
  • Notes
  • Recommended for high TDS samples
  • Type
  • High TDS
G8010-60236 Easy-fit 1.8mm semi-demountable torch for 5000 series VDV/SVDV ICP-OES. Features a 1.8mm ID injector with replaceable extended outer tube with slot for radial viewing. Recommended for routine analysis of aqueous samples. 785 
Add to Cart
  • UNSPSC Code
  • 41113000
  • Chemical Compatibility
  • Aqueous
  • Type
  • Aqueous
G8010-60237 Easy-fit 1.4mm semi-demountable torch for 5000 series RV (radial) ICP-OES. Features a 1.4mm ID injector with a replaceable shorter tube (no slot) for dedicated radial viewing. This torch is recommended for routine analysis of aqueous and semi-volatile org 785 
Add to Cart
  • UNSPSC Code
  • 41113000
  • Chemical Compatibility
  • Aqueous Semi-volatile organics
  • Type
  • Aqueous Semi-volatile organics

Overview

ICP-MS system operates with an ICP-MS Nebulizer, in which a high velocity Argon gas stream meets a liquid stream causing filmwise breakup of the solution into a fine aerosol. The aerosol particle size should ideally be sub-10µm with a narrow particle size distribution to achieve efficient atomization and ionization. Agilent offers a comprehensive range of ICP-MS nebulizers and supplies to solve any ICP-MS analysis challenge.

The portfolio includes standard glass concentric nebulizer (MicroMist), quartz and inert PFA nebulizers (MicroFlow and C-Flow), as well as robust Mira Mist PEEK or PTFE for high TDS samples and low-flow self-aspirating or total consumption nebulizers for your clinical or limited volume samples. ICP-MS nebulizer support is provided with a full range of accessories for all models including nebulizer cleaning tools.


The ICP torch is used to form, shape, and sustain an argon plasma which atomizes and ionizes the sample aerosol. Agilent ICP-MS Torches with Shield Torch System (STS) provide precise ion energy control, ensuring high sensitivity and stability, even in cool plasma mode for effective interference removal (ArO+).

Our portfolio is comprised of a wide range of ICP torches for your specific ICP-MS configuration. One-piece quartz torches offer the best stability and ease of use. The large 2.5mm injector on the standard torch gives maximum robustness and lowest matrix interferences for the best plasma stability. Single-piece torches with narrow bore injectors (1.0mm or 1.5 mm) are designed for use with organic solvents, to reduce plasma loading and improve plasma stability. Optional semi-demountable quartz torches with removable platinum or sapphire injectors are also available for use with the PFA inert sample introduction kit.