+852-3069 6950
css@gugent.com.hk
 

Agilent Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is available in single quadrupole and triple quadrupole configurations. Our single quadrupole ICP-MS address the range of typical ICP-MS measurements from routine, regulated analysis to advanced research and demanding applications. Our triple quadrupole ICP-MS will give you the confidence of knowing you can resolve problematic interferences – even in your most difficult samples – delivering results you know you can trust.

Catalog No. Product Net Price
AGIL0101-1399 Hydrogen high purity gas regulator, two-stage, stainless-steel body and diaphragms, 3000 psig inlet, 15 psig outlet, suits ICP-MS, Available in US only. CGA350 inlet with maximum pressure 3000 psig, outlet pressure 15 psig outlet with 30 psig gauge, 1/8 i 2984 
Add to Cart
  • UNSPSC Code
  • 41115411
G8000-64112 Pre-optic window for Agilent MP-AES 98 
Add to Cart
  • UNSPSC Code
  • 41115406
G8000-70004 Concentric nebulizer for Agilent MP-AES. Recommended for routine analysis of most sample types where high sensitivity is required 834 
Add to Cart
  • UNSPSC Code
  • 41115406
  • Chemical Compatibility
  • Aqueous Aromatic organics Ketone solvents
  • Gas Connector
  • Quick release
  • Material
  • Borosilicate glass
  • Name
  • Type K
  • Nebulizer Sample Particle Size Tolerance
  • 40 µm
  • Other Features
  • Not suitable for use with HF digests
  • Sample Connection
  • Direct
  • Sample Uptake Rate
  • 1
  • Self Aspirating
  • Yes
  • Type
  • Concentric
AGIL3710067900 Peristaltic pump tubing, PVC Solvaflex, blue/blue, for organics, 15/pk 81 
Add to Cart
  • Inner Diameter (ID)
  • 1.65 mm
  • Length
  • 450 mm
  • UNSPSC Code
  • 41115400
  • Chemical Compatibility
  • Aqueous Aromatic organics HF acid
  • Flared
  • No
  • Number of Stops
  • 2
  • Stop Color
  • Blue/Blue
  • Tubing Material
  • Solvaflex
AGIL3710068100 Peristaltic pump tubing, PVC Solva Flex, orange/green tabs with flared ends, 15/pk. Standard pump tubing supplied with the MP-AES for sample introduction. Recommended for most sample types including aqueous, HF digests and some organic solvents. 115 
Add to Cart
  • Inner Diameter (ID)
  • 0.38 mm
  • Length
  • 450 mm
  • UNSPSC Code
  • 41105106
  • Chemical Compatibility
  • Aqueous Aromatic organics HF acid
  • Flared
  • Yes
  • Number of Stops
  • 2
  • Stop Color
  • Orange/Green
  • Tubing Material
  • Solvaflex
AGIL3710068200 Peristaltic pump tubing, PVC, 2 tabs, orange/green, 0.38 mm id, for aqueous samples,12/pk 52 
Add to Cart
  • Inner Diameter (ID)
  • 0.38 mm
  • Length
  • 450 mm
  • UNSPSC Code
  • 40183000
  • Chemical Compatibility
  • Aqueous HF acid
  • Flared
  • No
  • Number of Stops
  • 2
  • Stop Color
  • Orange/Green
  • Tubing Material
  • PVC
AGIL3710068400 Peristaltic pump tubing, Santoprene, orange/green tabs, 0.38 mm id, for ketone-based organic samples, 12/pk 154 
Add to Cart
  • Inner Diameter (ID)
  • 0.38 mm
  • Length
  • 450 mm
  • UNSPSC Code
  • 40183000
  • Chemical Compatibility
  • Ketone solvents
  • Flared
  • No
  • Number of Stops
  • 2
  • Stop Color
  • Orange/Green
  • Tubing Material
  • Marprene
AGIL3710068500 Peristaltic pump tubing, Santoprene, orange/green tabs, flared ends, 0.38 mm id, for ketone-based organic samples, 12/pk 246 
Add to Cart
  • Inner Diameter (ID)
  • 0.38 mm
  • Length
  • 450 mm
  • UNSPSC Code
  • 40183000
  • Chemical Compatibility
  • Ketone solvents
  • Flared
  • Yes
  • Number of Stops
  • 2
  • Stop Color
  • Orange/Green
  • Tubing Material
  • Marprene
AGIL3710068600 Peristaltic pump tubing, FPM, orange/green tabs, 0.38 mm id, for aromatic organic samples, 12/pk 247 
Add to Cart
  • Inner Diameter (ID)
  • 0.38 mm
  • Length
  • 175 mm
  • UNSPSC Code
  • 40183000
  • Chemical Compatibility
  • Aromatic organics
  • Flared
  • No
  • Number of Stops
  • 2
  • Stop Color
  • Orange/Green
  • Tubing Material
  • FPM fluoroelastomer polymer
G8007-68000 PuraFlex transfer tube, for IsoMist used with Agilent MP-AES 269 
Add to Cart
  • UNSPSC Code
  • 41113000
  • Notes
  • Connects the aerosol outlet from the IsoMist to the Easy-fit MP-AES torch.

Overview

ICP-MS system operates with an ICP-MS Nebulizer, in which a high velocity Argon gas stream meets a liquid stream causing filmwise breakup of the solution into a fine aerosol. The aerosol particle size should ideally be sub-10µm with a narrow particle size distribution to achieve efficient atomization and ionization. Agilent offers a comprehensive range of ICP-MS nebulizers and supplies to solve any ICP-MS analysis challenge.

The portfolio includes standard glass concentric nebulizer (MicroMist), quartz and inert PFA nebulizers (MicroFlow and C-Flow), as well as robust Mira Mist PEEK or PTFE for high TDS samples and low-flow self-aspirating or total consumption nebulizers for your clinical or limited volume samples. ICP-MS nebulizer support is provided with a full range of accessories for all models including nebulizer cleaning tools.


The ICP torch is used to form, shape, and sustain an argon plasma which atomizes and ionizes the sample aerosol. Agilent ICP-MS Torches with Shield Torch System (STS) provide precise ion energy control, ensuring high sensitivity and stability, even in cool plasma mode for effective interference removal (ArO+).

Our portfolio is comprised of a wide range of ICP torches for your specific ICP-MS configuration. One-piece quartz torches offer the best stability and ease of use. The large 2.5mm injector on the standard torch gives maximum robustness and lowest matrix interferences for the best plasma stability. Single-piece torches with narrow bore injectors (1.0mm or 1.5 mm) are designed for use with organic solvents, to reduce plasma loading and improve plasma stability. Optional semi-demountable quartz torches with removable platinum or sapphire injectors are also available for use with the PFA inert sample introduction kit.


Resources