+852-3069 6950
css@gugent.com.hk
 

Sample preparation, or sample prep, is an essential part of chromatographic and spectroscopic analyses. The purpose of sample prep is to convert the sample into a form suitable for analysis without significant loss of target compounds. Proper sample preparation removes potentially interfering contamination, which extends the lifetime of your chromatography column and other instrument components.

Catalog No. Product Net Price
AGIL7551002C VersaPlate well plate tubes, LMS, 200 mg, 96/pk 319 
Add to Cart
  • Phase
  • LMS
  • UNSPSC Code
  • 41121701
  • Bed Mass
  • 200 mg
  • Frit Material
  • Polyethylene
  • Frit Pore Size
  • 20
  • Particle Size
  • 75 µm
  • SPE Category
  • Non-polar
  • SPE Format
  • VersaPlate
  • Volume
  • 1.8 mL
A4961010 Bond Elut LMS, 96 round-well plate, 1 mL, 10 mg, 1/pk 370 
Add to Cart
  • Phase
  • LMS
  • UNSPSC Code
  • 41115712
  • Bed Mass
  • 10 mg
  • Brand
  • Bond Elut
  • Frit Material
  • Polyethylene
  • Frit Pore Size
  • 20
  • Particle Size
  • 75 µm
  • Primary Extraction Mechanism
  • Nonpolar
  • Sorbent Material
  • Polymeric
  • SPE Category
  • Non-polar
  • SPE Format
  • 96 Round-Well Plate
  • Typical Matrices
  • Biological Fluids Plasma Serum Tissues Whole Blood
  • Volume
  • 1 mL
A3961010 Bond Elut LMS, 96 square-well plate, 2 mL, 10 mg, 1/pk 434 
Add to Cart
  • Phase
  • LMS
  • UNSPSC Code
  • 41115712
  • Bed Mass
  • 10 mg
  • Brand
  • Bond Elut
  • Frit Material
  • Polyethylene
  • Frit Pore Size
  • 20
  • Particle Size
  • 75 µm
  • Primary Extraction Mechanism
  • Nonpolar
  • Sorbent Material
  • Polymeric
  • SPE Category
  • Non-polar
  • SPE Format
  • 96 Square-Well Plate
  • Typical Matrices
  • Biological Fluids Plasma Serum Tissues Whole Blood
  • Volume
  • 2 mL
A3961025 Bond Elut LMS, 96 square-well plate, 2 mL, 25 mg, 1/pk 434 
Add to Cart
  • Phase
  • LMS
  • UNSPSC Code
  • 41115712
  • Bed Mass
  • 25 mg
  • Brand
  • Bond Elut
  • Frit Material
  • Polyethylene
  • Frit Pore Size
  • 20
  • Particle Size
  • 75 µm
  • Primary Extraction Mechanism
  • Nonpolar
  • Sorbent Material
  • Polymeric
  • SPE Category
  • Non-polar
  • SPE Format
  • 96 Square-Well Plate
  • Typical Matrices
  • Biological Fluids Plasma Serum Tissues Whole Blood
  • Volume
  • 2 mL
AGIL7541002C VersaPlate preassembled 96-well plate, LMS, 200 mg, 1/pk 452 
Add to Cart
  • Phase
  • LMS
  • UNSPSC Code
  • 41122102
  • Bed Mass
  • 200 mg
  • Frit Material
  • Polyethylene
  • Frit Pore Size
  • 20
  • Particle Size
  • 75 µm
  • SPE Category
  • Non-polar
  • SPE Format
  • VersaPlate
  • Volume
  • 1.8 mL
AGIL12105026 Bond Elut LMS cartridge, 500 mg, 3 mL, 50/pk 476 
Add to Cart
  • Phase
  • LMS
  • UNSPSC Code
  • 41115712
  • Bed Mass
  • 500 mg
  • Brand
  • Bond Elut
  • Cartridge Material
  • Polypropylene
  • Cartridge Size
  • 3 mL
  • Compound Types
  • Nonpolar Compounds
  • Frit Material
  • Polyethylene
  • Frit Pore Size
  • 20 µm
  • Particle Size
  • 75 µm
  • Primary Extraction Mechanism
  • Nonpolar
  • Separation Mode
  • Reversed Phase
  • Sorbent Material
  • Polymeric
  • SPE Category
  • Non-Polar
  • SPE Format
  • Straight Barrel Cartridge
  • Tabless
  • No
  • Typical Matrices
  • Biological Fluids Plasma Serum Tissues Whole Blood
  • Volume
  • 3 mL
AGIL12113100 Bond Elut NEXUS cartridge, LRC, 30 mg, 10 mL, 50/pk 126 
Add to Cart
  • Phase
  • NEXUS
  • UNSPSC Code
  • 41115712
  • Bed Mass
  • 30 mg
  • Brand
  • Bond Elut
  • Cartridge Material
  • Polypropylene
  • Cartridge Size
  • 10 mL
  • Compound Types
  • Nonpolar Compounds
  • Frit Material
  • Polyethylene
  • Frit Pore Size
  • 20 µm
  • Particle Size
  • 70 µm
  • Primary Extraction Mechanism
  • Nonpolar
  • Separation Mode
  • Reversed Phase
  • Sorbent Material
  • Polymeric
  • SPE Category
  • Mixed Mode
  • SPE Format
  • LRC
  • Tabless
  • No
  • Typical Matrices
  • Biological Fluids Horse Urine Urine
  • Volume
  • 10 mL
AGIL12113101 Bond Elut NEXUS cartridge, LRC, 60 mg, 10 mL, 50/pk 144 
Add to Cart
  • Phase
  • NEXUS
  • UNSPSC Code
  • 41115712
  • Bed Mass
  • 60 mg
  • Brand
  • Bond Elut
  • Cartridge Material
  • Polypropylene
  • Cartridge Size
  • 10 mL
  • Compound Types
  • Nonpolar Compounds
  • Frit Material
  • Polyethylene
  • Frit Pore Size
  • 20 µm
  • Particle Size
  • 70 µm
  • Primary Extraction Mechanism
  • Nonpolar
  • Separation Mode
  • Reversed Phase
  • Sorbent Material
  • Polymeric
  • SPE Category
  • Mixed Mode
  • SPE Format
  • LRC
  • Tabless
  • No
  • Typical Matrices
  • Biological Fluids Horse Urine Urine
  • Volume
  • 10 mL
AGIL5610-2035 Bond Elut NEXUS WCX, 150mg 6mL, 30/PK 172 
Add to Cart
  • Phase
  • NEXUS WCX
  • Bed Mass
  • 150 mg
  • Brand
  • Bond Elut
  • Cartridge Material
  • Polypropylene
  • Cartridge Size
  • 6 mL
  • Compound Types
  • Strong Basic Compounds
  • Frit Material
  • Polyethylene
  • Frit Pore Size
  • 20 µm
  • Particle Size
  • 70 µm
  • Primary Extraction Mechanism
  • Strong Cation Exchange
  • Separation Mode
  • Reversed Phase
  • Sorbent Material
  • Polymeric
  • SPE Format
  • Straight Barrel Cartridge
  • Volume
  • 6 mL
AGIL12103100 Bond Elut NEXUS cartridge, 30 mg, 1 mL, 100/pk 200 
Add to Cart
  • Phase
  • NEXUS
  • UNSPSC Code
  • 41115712
  • Bed Mass
  • 30 mg
  • Brand
  • Bond Elut
  • Cartridge Material
  • Polypropylene
  • Cartridge Size
  • 1 mL
  • Compound Types
  • Nonpolar Compounds
  • Frit Material
  • Polyethylene
  • Frit Pore Size
  • 20 µm
  • Particle Size
  • 70 µm
  • Primary Extraction Mechanism
  • Nonpolar
  • Separation Mode
  • Reversed Phase
  • Sorbent Material
  • Polymeric
  • SPE Category
  • Mixed Mode
  • SPE Format
  • Straight Barrel Cartridge
  • Tabless
  • No
  • Typical Matrices
  • Biological Fluids Horse Urine Urine
  • Volume
  • 1 mL

Overview

Agilent's suite of sample preparation products ensure you have the right product for your needs. Our purification and filtration products provide quick and reliable results for repeated analyses and are ideal for busy, high-throughput laboratories. Pre-packaged QuEChERS extraction and dispersive solid phase extraction (dSPE) kits are ideal for food samples and accommodate AOAC and EN methodologies. We also offer a full portfolio of solid supported liquid extraction (SLE), solid phase extraction (SPE), and solid phase microextraction (SPME) products in various chemistries and formats to achieve excellent performance and ensure samples are free of interferences, even with complex matrices.


Resources