+852-3069 6950
css@gugent.com.hk
 

ICP-MS Consumables & Accessories

Each part is fit to perform and is manufactured with the highest quality materials available. Selection of the correct components can help speed your analyses, increase repeatability of results and minimize errors. Our precision designed products deliver the peace of mind that comes from knowing that you’ll get the results you need. Whether you are looking for sample introduction components or standards, we have the consumables you need to keep your ICP-MS up and running smoothly and efficiently. Choose from our variety of torches, nebulizers, spray chambers, injectors, cones, and autosampler supplies.


ICP-OES Consumables & Accessories

Your sample introduction system plays an important role in your ICP-OES analysis. Selection of the correct components can help speed your analyses, increase repeatability of results and minimize errors. Our precision designed products deliver the peace of mind that comes from knowing that you’ll get the results you need. Choose from our variety of torches, nebulizers, spray chambers, injectors, and autosampler supplies.


Catalog No. Product Net Price
WE024375 PFA Sample Uptake Tubing 11 
Add to Cart
  • Product Group
  • Capillary Assemblies and Tubing
  • Product Brand Name
  • MEINHARD
  • Product Compatibility
  • NexION 2000, NexION 300, NexION 350, NexION 1000
  • Material
  • PFA
N0777434 S10/AS93/ASX PTFE Flame Sampling Probe Assembly 358 
Add to Cart
  • Product Group
  • Probes
  • Technology Type
  • AA
W1012409 PTFE Injector Spacer for NexION 300/350 22 
Add to Cart
  • Product Group
  • Adapters and Replacement Parts
  • Product Compatibility
  • NexION 300, NexION 350
  • Material
  • PTFE
PE09985708 PTFE Tubing for GemTip/GemCone Nebulizers, 1 ft. 6 
Add to Cart
  • Product Group
  • Capillary Assemblies and Tubing
  • Technology Type
  • ICP-OES
  • Product Brand Name
  • GemTip, GemCone
  • Product Compatibility
  • Avio 500, NexION 2000, Optima 4x00 DV, Optima 2x00 DV, Avio 200, NexION 1000, Optima 5x00 DV, Optima 7x00 DV, Optima 8x00
N8145120 High Purity Quartz Baffled Cyclonic Spray Chamber with Gas Port for NexION 300/350 PC3 Systems 1155 
Add to Cart
  • Product Group
  • Spray Chambers
  • Type
  • Baffled and Cyclonic
  • Product Compatibility
  • NexION 300, NexION 350
  • Material
  • Quartz
N0777034 Quartz Baffled Cyclonic Spray Chamber with Gas Port for ELAN 5000/6x00/9000/DRCs PC3 Systems 880 
Add to Cart
  • Product Group
  • Spray Chambers
  • Technology Type
  • ICP-MS
  • Type
  • Baffled and Cyclonic
  • Product Compatibility
  • ELAN 5000, ELAN 9000, ELAN DRC II, ELAN 6x00, ELAN DRC-e
  • Material
  • Quartz
WE025221 Quartz Baffled Cyclonic Spray Chamber for ELAN DRC/DRCplus/DRC II 880 
Add to Cart
  • Product Group
  • Spray Chambers
  • Type
  • Baffled and Cyclonic
  • Product Compatibility
  • ELAN DRC II
  • Material
  • Quartz
N8145013 O-Ring Free Quartz Baffled Cyclonic Spray Chamber for NexION 300/350 605 
Add to Cart
  • Product Group
  • Spray Chambers
  • Type
  • Baffled and Cyclonic
  • Product Compatibility
  • NexION 300, NexION 350
  • Material
  • Quartz
N8145121 Quartz Baffled Micro Cyclonic Spray Chamber for NexION 300/350 PC3 Systems 825 
Add to Cart
  • Product Group
  • Spray Chambers
  • Type
  • Baffled and Cyclonic
  • Product Compatibility
  • NexION 300, NexION 350
  • Material
  • Quartz
N8145114 Demountable Quartz Injector, 1.0 mm I.D. - O-Ring Free 396 
Add to Cart
  • Inner Diameter
  • 1.0 mm
  • Product Group
  • Injectors
  • Product Compatibility
  • NexION 300, NexION 350
  • Material
  • Quartz

Overview

Cones

Our Cones are precision-designed and manufactured providing the best analytical results. We invest heavily in testing and validating our complete portfolio of products to ensure that you receive accurate, repeatable results, on-time, every time throughout the lifetime of your instrument. Large-orifice sampler and skimmer cones provide superior long-term stability and resist clogging, allowing analysis under both high and low sample-uptake conditions. Choose from Nickel and Platinum Cones.


Humidifiers

Argon Humidifiers are commonly used in ICP analyses involving samples with high concentrations of dissolved solids. It helps to alleviate salt deposits in the nebulizer and torch injector, allowing uninterrupted and maintenance-free operation.


Injectors

We offer a complete selection of injectors in various sizes and materials to meet all of your application needs. Choose from Alumina, Sapphire and Quartz injectors. Alumina injectors are corrosion-resistant to all mineral acids including HF and aqua regia. Quartz injectors are designed for organic solvents and non-HF matrices. Sapphire injectors are ideal for silicon applications.


Nebulizers

We offer a complete selection of nebulizers in a variety of materials for all of your application needs. Selection of the correct components can help speed your analyses, increase repeatability of results and minimize errors. Not every sample introduction system is ideal for every application. Each combination has a unique advantage based on your particular sample needs. Choose from Concentric, MicroFlow, and GemClean nebulizers.


Sample Introduction Kits

We offer a selection of Sample Introduction Kits, Sample Introduction Modules, and Consumables Kits for your specific application needs. Not every sample introduction system is ideal for every application. Each combination has a unique advantage based on your particular sample needs. Each kit is designed for your instrument model for your convenience.


Spray Chambers

The spray chamber is an integral part of the sample introduction System. Selection of the correct components can help speed your analyses, increase repeatability of results and minimize errors. Each type of spray chamber has been tested to provide the best performance and analytical results. Not every sample introduction system is ideal for every application. Each combination has a unique advantage based on your particular sample needs. With more sampling and application options than ever before, let us work with you to best understand your laboratory requirements and recommend the best option. Choose from Baffled Cyclonic, Scott Spray and PFA Spray Chambers.


Torches

We carefully select the best materials that provide optimal performance. The right consumables, methods and application support are as integral to the success of your laboratory as your instrumentation. That’s why we invest heavily in testing and validating our complete portfolio of solutions to ensure that you receive accurate, repeatable results, on-time, every time throughout the lifetime of your instrument. Torches are specifically designed for your instrument. Trust the consumables engineered for your instruments. Choose from Demountable Quartz, Fixed, and D-Torches.



Resources