+852-3069 6950
css@gugent.com.hk
 

Filters and filtration products are used for applications requiring filtration or purification of a variety of samples. Products include bottle-top filters, filter units, concentrators, and a wide range of other filtration devices and supplies.

Catalog No. Product Net Price
THM-F2504-7 Target2™ Regenerated Cellulose Syringe Filters 226.5 
Add to Cart
  • 4 mm
  • 0.45 μm
  • Target2
  • Pack of 100
  • Syringe Filter
  • Target2 Regenerated Cellulose Syringe Filter 0.45 µm, 4 mm, 100 Pk.
  • HPLC, SPE
  • Target Polypropylene Syringe Filter Housings Meet The Requirements of 21 CFR 177.1520. Membrane: HPLC Certified Regenerated Cellulose.
  • <15 μL (Hold Up)
THM-F2504-8 Target2™ Regenerated Cellulose Syringe Filters 228.61 
Add to Cart
  • 4 mm
  • 0.2 μm
  • Target2
  • Pack of 100
  • Syringe Filter
  • Target2 Regenerated Cellulose Syringe Filter 0.2 µm, 4 mm, 100 Pk.
  • HPLC, SPE
  • Target Polypropylene Syringe Filter Housings Meet The Requirements of 21 CFR 177.1520. Membrane: HPLC Certified Regenerated Cellulose.
  • <15 μL (Hold Up)
THM-F2513-7 Target2™ Regenerated Cellulose Syringe Filters 294.24 
Add to Cart
  • 17 mm
  • 0.45 μm
  • Target2
  • Pack of 100
  • Syringe Filter
  • Target2 Regenerated Cellulose Syringe Filter 0.45 µm, 17 mm, 100 Pk.
  • HPLC, SPE
  • Target Polypropylene Syringe Filter Housings Meet The Requirements of 21 CFR 177.1520. Membrane: HPLC Certified Regenerated Cellulose.
  • <29 μL (Hold Up)
THM-F2513-8 Target2™ Regenerated Cellulose Syringe Filters 306.94 
Add to Cart
  • 17 mm
  • 0.2 μm
  • Target2
  • Pack of 100
  • Syringe Filter
  • Target2 Regenerated Cellulose Syringe Filter 0.2 µm, 17 mm, 100 Pk.
  • HPLC, SPE
  • Target Polypropylene Syringe Filter Housings Meet The Requirements of 21 CFR 177.1520. Membrane: HPLC Certified Regenerated Cellulose.
  • <29 μL (Hold Up)
THM-F2500-7 Target2™ Regenerated Cellulose Syringe Filters 423.36 
Add to Cart
  • 30 mm
  • 0.45 μm
  • Target2
  • Pack of 100
  • Syringe Filter
  • Target2 Regenerated Cellulose Syringe Filter 0.45 µm, 30 mm, 100 Pk.
  • HPLC, SPE
  • Target Polypropylene Syringe Filter Housings Meet The Requirements of 21 CFR 177.1520. Membrane: HPLC Certified Regenerated Cellulose.
  • <137 μL (Hold Up)
THM-F2500-8 Target2™ Regenerated Cellulose Syringe Filters 522.85 
Add to Cart
  • 30 mm
  • 0.2 μm
  • Target2
  • Pack of 100
  • Syringe Filter
  • Target2 Regenerated Cellulose Syringe Filter 0.2 µm, 30 mm, 100 Pk.
  • HPLC, SPE
  • Target Polypropylene Syringe Filter Housings Meet The Requirements of 21 CFR 177.1520. Membrane: HPLC Certified Regenerated Cellulose.
  • <137 μL (Hold Up)
THM-44504-NP Titan3™ PTFE (Hydrophobic) Syringe Filters 203.21 
Add to Cart
  • 4 mm
  • 0.45 μm
  • Titan3
  • Pack of 100
  • Syringe Filter
  • Titan3 PTFE (Hydrophobic) Syringe Filter 0.45 µm, 4 mm, 100 Pk.
  • Sample Filtration: aggressive organic, highly basic, or hot solutions, aqueous solutions without prewetting with an alcohol
  • Titan3 Polypropylene Syringe Filter Housings Meet The Requirements of 21 CFR 177.1520. Membrane: HPLC Certified PTFE, with Polypropylene Support .
  • <15 μL (Hold Up)
THM-42204-NP Titan3™ PTFE (Hydrophobic) Syringe Filters 205.33 
Add to Cart
  • 4 mm
  • 0.2 μm
  • Titan3
  • Pack of 100
  • Syringe Filter
  • Titan3 PTFE (Hydrophobic) Syringe Filter 0.2 µm, 4 mm, 100 Pk.
  • Sample Filtration: aggressive organic, highly basic, or hot solutions, aqueous solutions without prewetting with an alcohol
  • Titan3 Polypropylene Syringe Filter Housings Meet The Requirements of 21 CFR 177.1520. Membrane: HPLC Certified PTFE, with Polypropylene Support .
  • <15 μL (Hold Up)
THM-41025-NP Titan3™ PTFE (Hydrophobic) Syringe Filters 359.86 
Add to Cart
  • 30 mm
  • 1.0 μm
  • Titan3
  • Pack of 100
  • Syringe Filter
  • Titan3 PTFE (Hydrophobic) Syringe Filter 1 µm, 30 mm, 100 Pk.
  • Sample Filtration: aggressive organic, highly basic, or hot solutions, aqueous solutions without prewetting with an alcohol
  • Titan3 Polypropylene Syringe Filter Housings Meet The Requirements of 21 CFR 177.1520. Membrane: HPLC Certified PTFE, with Polypropylene Support .
  • <137 μL (Hold Up)
THM-42225-NP Titan3™ PTFE (Hydrophobic) Syringe Filters 378.91 
Add to Cart
  • 30 mm
  • 0.2 μm
  • Titan3
  • Pack of 100
  • Syringe Filter
  • Titan3 PTFE (Hydrophobic) Syringe Filter 0.2 µm, 30 mm, with Pre-Filter, 100 Pk.
  • Sample Filtration: aggressive organic, highly basic, or hot solutions, aqueous solutions without prewetting with an alcohol
  • Titan3 Polypropylene Syringe Filter Housings Meet The Requirements of 21 CFR 177.1520. Membrane: HPLC Certified PTFE, with Polypropylene Support .

Overview

Eliminate particles and microorganisms from your sample — reliably


Prevent the accumulation of fine particles that can block your chromatography column. Thermo Scientific Titan3, Target2, and Choice SyringeFilters remove interfering materials, fine particles, and microorganisms, providing you with cleaner sample extracts. These high-quality robust sample filtration solutions are available in a variety of syringe filter sizes, membranes, and housings for a wide range of samples and applications.



Resources