+852-3069 6950
css@gugent.com.hk
 

Lab Filtration & Purification


Separation technology is often an important element in laboratory-based research, development, analytics and diagnostics across all major applications and workflows. From the isolation of biologics in cell line development to sample preparation of waste water in epidemiology and the concentration of disease markers from human samples, Sartorius combines its wide range of application knowledge and innovative products to reduce specimen-to-report timelines and ensure efficient and easy filtration and purification processes. 


Catalog No. Product Net Price
17764----------Q Minisart® RC25 Syringe Filter 17764----------Q, 0.2 µm Regenerated Cellulose 800 
Add to Cart
  • Application Area
  • Analytical Sample Preparation
  • Connector Inlet
  • Female Luer Lock
  • Connector Outlet
  • Male Luer Slip
  • Filter Diameter
  • ⌀ 25 mm
  • Filtration Area
  • 4.8 cm²
  • Filter Paper/Membrane Color
  • White (opaque) Printed
  • Flow Rate
  • ≥ 80 mL/min for water at 1 bar (14.5 psi) | ≥ 160 mL/min for methanol at 1 bar (14.5 psi)
  • Total Throughput
  • Up to 100 mL
  • pH Range
  • 3.0 – 14.0
  • Housing Material
  • Polypropylene (PP)
  • Membrane Material
  • Regenerated Cellulose (RC)
  • Maximum Allowable Working Temperature
  • 60°C
  • Maximum Operating Pressure
  • 4.5 bar (65 psi)
  • Bubble Point
  • ≥ 3.0 bar (44 psi) with water
  • Burst Pressure
  • ≥ 7.0 bar (102 psi)
  • Pore Size
  • 0.2 µm
  • Wettability
  • Hydrophilic
  • Brand
  • Minisart® RC
  • Device Type
  • Syringe Filters
  • Pack Size
  • 500
  • Packaging
  • Bulk packed
  • Sample Type
  • Aqueous Solvents Solvent Mixtures
  • Delivery Condition
  • Non-Sterile
  • Sterilization Method
  • Ethylene oxide Autoclave
  • Hold-up Volume
  • ≤ 100 – 200 µL
17764----------S Minisart® RC25 Syringe Filter 17764----------S, 0.2 µm Regenerated Cellulose 370 
Add to Cart
  • Application Area
  • Analytical Sample Preparation
  • Connector Inlet
  • Female Luer Lock
  • Connector Outlet
  • Male Luer Slip
  • Filter Diameter
  • ⌀ 25 mm
  • Filtration Area
  • 4.8 cm²
  • Filter Paper/Membrane Color
  • White (opaque) Printed
  • Flow Rate
  • ≥ 80 mL/min for water at 1 bar (14.5 psi) | ≥ 160 mL/min for methanol at 1 bar (14.5 psi)
  • Total Throughput
  • Up to 100 mL
  • pH Range
  • 3.0 – 14.0
  • Housing Material
  • Polypropylene (PP)
  • Membrane Material
  • Regenerated Cellulose (RC)
  • Maximum Allowable Working Temperature
  • 60°C
  • Maximum Operating Pressure
  • 4.5 bar (65 psi)
  • Bubble Point
  • ≥ 3.0 bar (44 psi) with water
  • Burst Pressure
  • ≥ 7.0 bar (102 psi)
  • Pore Size
  • 0.2 µm
  • Wettability
  • Hydrophilic
  • Brand
  • Minisart® RC
  • Device Type
  • Syringe Filters
  • Pack Size
  • 200
  • Packaging
  • Bulk packed
  • Sample Type
  • Aqueous Solvents Solvent Mixtures
  • Delivery Condition
  • Non-Sterile
  • Sterilization Method
  • Ethylene oxide Autoclave
  • Hold-up Volume
  • ≤ 100 – 200 µL
17764--------ACK Minisart® RC25 Syringe Filter 17764--------ACK, 0.2 µm Regenerated Cellulose 131 
Add to Cart
  • Application Area
  • Analytical Sample Preparation
  • Connector Inlet
  • Female Luer Lock
  • Connector Outlet
  • Male Luer Slip
  • Filter Diameter
  • ⌀ 25 mm
  • Filtration Area
  • 4.8 cm²
  • Filter Paper/Membrane Color
  • White (opaque) Printed
  • Flow Rate
  • ≥ 50 mL/min for water at 1 bar (14.5 psi) |≥ 90 mL/min for methanol at 1 bar (14.5 psi)
  • Total Throughput
  • Up to 100 mL
  • pH Range
  • 3.0 – 14.0
  • Housing Material
  • Polypropylene (PP)
  • Membrane Material
  • Regenerated Cellulose (RC)
  • Maximum Allowable Working Temperature
  • 121 °C (250 °F)
  • Maximum Operating Pressure
  • 4.5 bar (65 psi)
  • Bubble Point
  • ≥ 4.6 bar (67 psi) with water
  • Burst Pressure
  • ≥ 7.0 bar (102 psi)
  • Pore Size
  • 0.2 µm
  • Wettability
  • Hydrophilic
  • Brand
  • Minisart® RC
  • Device Type
  • Syringe Filters
  • Pack Size
  • 50
  • Packaging
  • Single blister packed
  • Sample Type
  • Aqueous Solvents Solvent Mixtures
  • Delivery Condition
  • Sterile
  • Sterilization Method
  • Ethylene oxide
  • Hold-up Volume
  • ≤ 100 – 200 µL
17765--------ACK Minisart® RC25 Syringe Filter 17765----------ACK, 0.45 µm Regenerated Cellulose 127 
Add to Cart
  • Application Area
  • Analytical Sample Preparation
  • Connector Inlet
  • Female Luer Lock
  • Connector Outlet
  • Male Luer Slip
  • Filter Diameter
  • ⌀ 25 mm
  • Filtration Area
  • 4.8 cm²
  • Filter Paper/Membrane Color
  • White (opaque) Printed
  • Flow Rate
  • ≥ 160 mL/min for water at 1 bar (14.5 psi) | ≥ 325 mL/min for methanol at 1 bar (14.5 psi)
  • Total Throughput
  • Up to 100 mL
  • pH Range
  • 3.0 – 14.0
  • Housing Material
  • Polypropylene (PP)
  • Membrane Material
  • Regenerated Cellulose (RC)
  • Maximum Allowable Working Temperature
  • 60°C
  • Maximum Operating Pressure
  • 4.5 bar (65 psi)
  • Bubble Point
  • ≥ 2.0 bar (29 psi) with water
  • Burst Pressure
  • ≥ 7.0 bar (102 psi)
  • Pore Size
  • 0.45 µm
  • Wettability
  • Hydrophilic
  • Brand
  • Minisart® RC
  • Device Type
  • Syringe Filters
  • Pack Size
  • 50
  • Packaging
  • Bulk packed
  • Sample Type
  • Aqueous Solvents Solvent Mixtures
  • Delivery Condition
  • Sterile
  • Sterilization Method
  • Ethylene oxide Autoclave
  • Hold-up Volume
  • ≤ 100 – 200 µL
17765----------R Minisart® RC25 Syringe Filter 17765----------R, 0.45 µm Regenerated Cellulose 1568 
Add to Cart
  • Application Area
  • Analytical Sample Preparation
  • Connector Inlet
  • Female Luer Lock
  • Connector Outlet
  • Male Luer Slip
  • Filter Diameter
  • ⌀ 25 mm
  • Filtration Area
  • 4.8 cm²
  • Filter Paper/Membrane Color
  • White (opaque) Printed
  • Flow Rate
  • ≥ 160 mL/min for water at 1 bar (14.5 psi) | ≥ 325 mL/min for methanol at 1 bar (14.5 psi)
  • Total Throughput
  • Up to 100 mL
  • pH Range
  • 3.0 – 14.0
  • Housing Material
  • Polypropylene (PP)
  • Membrane Material
  • Regenerated Cellulose (RC)
  • Maximum Allowable Working Temperature
  • 60°C
  • Maximum Operating Pressure
  • 4.5 bar (65 psi)
  • Bubble Point
  • ≥ 2.0 bar (29 psi) with water
  • Burst Pressure
  • ≥ 7.0 bar (102 psi)
  • Pore Size
  • 0.45 µm
  • Wettability
  • Hydrophilic
  • Brand
  • Minisart® RC
  • Device Type
  • Syringe Filters
  • Pack Size
  • 1000
  • Packaging
  • Bulk packed
  • Sample Type
  • Aqueous Solvents Solvent Mixtures
  • Delivery Condition
  • Non-Sterile
  • Sterilization Method
  • Ethylene oxide Autoclave
  • Hold-up Volume
  • ≤ 100 – 200 µL
17821----------K Minisart® RC4 Syringe Filter 17821----------K, 0.2 µm Regenerated Cellulose 74 
Add to Cart
  • Application Area
  • Analytical Sample Preparation
  • Connector Inlet
  • Female Luer Lock
  • Connector Outlet
  • Male Luer Slip
  • Filter Diameter
  • ⌀ 4 mm
  • Filtration Area
  • 0.1 cm²
  • Filter Paper/Membrane Color
  • Blue
  • Flow Rate
  • ≥ 0.5 mL/min for water at 1 bar (14.5 psi) | ≥ 1.5 mL/min for methanol at 1 bar (14.5 psi)
  • Total Throughput
  • Up to 1 mL
  • pH Range
  • 3.0 – 14.0
  • Housing Material
  • Polypropylene (PP)
  • Membrane Material
  • Regenerated Cellulose (RC)
  • Maximum Allowable Working Temperature
  • 60°C
  • Maximum Operating Pressure
  • 4.5 bar (65 psi)
  • Bubble Point
  • ≥ 3.0 bar (44 psi) with water
  • Burst Pressure
  • ≥ 7.0 bar (102 psi)
  • Pore Size
  • 0.2 µm
  • Wettability
  • Hydrophilic
  • Brand
  • Minisart® RC
  • Device Type
  • Syringe Filters
  • Pack Size
  • 50
  • Packaging
  • Bulk packed
  • Sample Type
  • Aqueous Solvents Solvent Mixtures
  • Delivery Condition
  • Non-Sterile
  • Sterilization Method
  • Ethylene oxide Autoclave
  • Hold-up Volume
  • ≤ 5 – 10 µL
17821----------Q Minisart® RC4 Syringe Filter 17821----------Q, 0.2 µm Regenerated Cellulose 648 
Add to Cart
  • Application Area
  • Analytical Sample Preparation
  • Connector Inlet
  • Female Luer Lock
  • Connector Outlet
  • Male Luer Slip
  • Filter Diameter
  • ⌀ 4 mm
  • Filtration Area
  • 0.1 cm²
  • Filter Paper/Membrane Color
  • Blue
  • Flow Rate
  • ≥ 0.5 mL/min for water at 1 bar (14.5 psi) | ≥ 1.5 mL/min for methanol at 1 bar (14.5 psi)
  • Total Throughput
  • Up to 1 mL
  • pH Range
  • 3.0 – 14.0
  • Housing Material
  • Polypropylene (PP)
  • Membrane Material
  • Regenerated Cellulose (RC)
  • Maximum Allowable Working Temperature
  • 60°C
  • Maximum Operating Pressure
  • 4.5 bar (65 psi)
  • Bubble Point
  • ≥ 3.0 bar (44 psi) with water
  • Burst Pressure
  • ≥ 7.0 bar (102 psi)
  • Pore Size
  • 0.2 µm
  • Wettability
  • Hydrophilic
  • Brand
  • Minisart® RC
  • Device Type
  • Syringe Filters
  • Pack Size
  • 500
  • Packaging
  • Bulk packed
  • Sample Type
  • Aqueous Solvents Solvent Mixtures
  • Delivery Condition
  • Non-Sterile
  • Sterilization Method
  • Ethylene oxide Autoclave
  • Hold-up Volume
  • ≤ 5 – 10 µL
17822----------K Minisart® RC4 Syringe Filter 17822----------K, 0.45 µm Regenerated Cellulose 74 
Add to Cart
  • Application Area
  • Analytical Sample Preparation
  • Connector Inlet
  • Female Luer Lock
  • Connector Outlet
  • Male Luer Slip
  • Filter Diameter
  • ⌀ 4 mm
  • Filtration Area
  • 0.1 cm²
  • Filter Paper/Membrane Color
  • Yellow
  • Flow Rate
  • ≥ 1.5 mL/min for water at 1 bar (14.5 psi) | ≥ 3 mL/min for methanol at 1 bar (14.5 psi)
  • Total Throughput
  • Up to 1 mL
  • pH Range
  • 3.0 – 14.0
  • Housing Material
  • Polypropylene (PP)
  • Membrane Material
  • Regenerated Cellulose (RC)
  • Maximum Allowable Working Temperature
  • 60°C
  • Maximum Operating Pressure
  • 4.5 bar (65 psi)
  • Bubble Point
  • ≥ 2.0 bar (29 psi) with water
  • Burst Pressure
  • ≥ 7.0 bar (102 psi)
  • Pore Size
  • 0.45 µm
  • Wettability
  • Hydrophilic
  • Brand
  • Minisart® RC
  • Device Type
  • Syringe Filters
  • Pack Size
  • 50
  • Packaging
  • Bulk packed
  • Sample Type
  • Aqueous Solvents Solvent Mixtures
  • Delivery Condition
  • Non-Sterile
  • Sterilization Method
  • Ethylene oxide Autoclave
  • Hold-up Volume
  • ≤ 5 – 10 µL
17822----------Q Minisart® RC4 Syringe Filter 17822----------Q, 0.45 µm Regenerated Cellulose 648 
Add to Cart
  • Application Area
  • Analytical Sample Preparation
  • Connector Inlet
  • Female Luer Lock
  • Connector Outlet
  • Male Luer Slip
  • Filter Diameter
  • ⌀ 4 mm
  • Filtration Area
  • 0.1 cm²
  • Filter Paper/Membrane Color
  • Yellow
  • Flow Rate
  • ≥ 1.5 mL/min for water at 1 bar (14.5 psi) | ≥ 3 mL/min for methanol at 1 bar (14.5 psi)
  • Total Throughput
  • Up to 1 mL
  • pH Range
  • 3.0 – 14.0
  • Housing Material
  • Polypropylene (PP)
  • Membrane Material
  • Regenerated Cellulose (RC)
  • Maximum Allowable Working Temperature
  • 60°C
  • Maximum Operating Pressure
  • 4.5 bar (65 psi)
  • Bubble Point
  • ≥ 2.0 bar (29 psi) with water
  • Burst Pressure
  • ≥ 7.0 bar (102 psi)
  • Pore Size
  • 0.45 µm
  • Wettability
  • Hydrophilic
  • Brand
  • Minisart® RC
  • Device Type
  • Syringe Filters
  • Pack Size
  • 500
  • Packaging
  • Bulk packed
  • Sample Type
  • Aqueous Solvents Solvent Mixtures
  • Delivery Condition
  • Non-Sterile
  • Sterilization Method
  • Ethylene oxide Autoclave
  • Hold-up Volume
  • ≤ 5 – 10 µL
17761--------ACK Minisart® RC15 Syringe Filter 17761--------ACK, 0.2 µm Regenerated Cellulose 115 
Add to Cart
  • Application Area
  • Analytical Sample Preparation
  • Connector Inlet
  • Female Luer Lock
  • Connector Outlet
  • Male Luer Slip
  • Filter Diameter
  • ⌀ 15 mm
  • Filtration Area
  • 1.7 cm²
  • Filter Paper/Membrane Color
  • White (opaque) Printed
  • Flow Rate
  • 10 mL/min with water at 1 bar (14.5 psi) | 25 mL/min with methanol at 1 bar (14.5 psi)
  • Total Throughput
  • Up to 15 mL
  • pH Range
  • 3.0 – 14.0
  • Housing Material
  • Polypropylene (PP)
  • Membrane Material
  • Regenerated Cellulose (RC)
  • Maximum Allowable Working Temperature
  • 121 °C (250 °F)
  • Maximum Operating Pressure
  • 4.5 bar (65 psi)
  • Bubble Point
  • ≥ 4.6 bar (67 psi) with water
  • Burst Pressure
  • ≥ 7.0 bar (102 psi)
  • Pore Size
  • 0.2 µm
  • Wettability
  • Hydrophilic
  • Brand
  • Minisart® RC
  • Device Type
  • Syringe Filters
  • Pack Size
  • 50
  • Packaging
  • Single blister packed
  • Sample Type
  • Aqueous Solvents Solvent Mixtures
  • Delivery Condition
  • Sterile
  • Sterilization Method
  • Ethylene oxide
  • Hold-up Volume
  • ≤ 30 – 100 µL