+852-3069 6950
css@gugent.com.hk
 

Process Analytics


Process Instrumentation for measuring pH, Dissolved Oxygen, Conductivity, Turbidity, TOC, Sodium, Silica, Gas Analyzer


Catalog No. Product Net Price
METL30541121 Turbidity Sensor InPro8630ie Special offer 
Add to Cart
  • Connection
  • 5-pin
  • Hazardous Area Approvals
  • No
  • Hygienic/Biocompatibility Approvals
  • EHEDG, FDA/USP Class VI
  • Intelligent Sensor Management (ISM®)
  • Yes
  • Light Source
  • Internal
  • Light Technology
  • LED
  • Measured Pressure Resistance
  • 0 psi – 232 psi (0 bar – 16 bar)
  • Measurement Angle
  • 25 ° 90 °
  • Measurement Parameter
  • Color Turbidity
  • Measuring Temp. Range
  • 14 °F – 248 °C (-10 °C – 120 °C)
  • Model Family
  • InPro 8600 Series
  • Operating Range EBC Color
  • 0 – 50
  • Operating Range EBC Turbidity
  • 0 – 1,000
  • Operating Range FTU Turbidity
  • 0 – 4,000
  • Primary Media/Application
  • Other Water Processes Food and Beverage Food/Beverage Production
  • Process Connection
  • Varivent®
  • Sterilizable/Autoclavable
  • No
  • Temp. Range
  • 14 °F – 248 °C (-10 °C – 120 °C)
  • Wetted Materials
  • C22, Sapphire
  • Window
  • Sapphire
METL30389700 pH Sensor InPro X1 HLS-N200-K120 Special offer 
Add to Cart
  • Cable Connector
  • K8S
  • Certificates & Approvals
  • CE METTLER TOLEDO Quality Certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG/T6 EHEDG EC1935/2004 ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb 3A PED
  • Connection
  • Pg 13.5 Thread
  • Hazardous Area Approvals
  • Yes
  • Hygienic/Biocompatibility Approvals
  • Yes
  • ISM (Digital) or Analog
  • ISM (Digital)
  • Measurement Parameter
  • pH
  • Model Family
  • InPro X1 HLS
  • Operating Pressure (Bar)
  • 0 to 4 barg
  • Operating Pressure (PSI)
  • 0 to 58 psig
  • Operating Temperature (Celsius)
  • 0 °C - 80 °C
  • Operating Temperature (Fahrenheit)
  • 32 °F - 176 °F
  • pH Range
  • 0 – 14
  • pH Sensing Technology
  • Composite X-Chip
  • Primary Media/Application
  • Food/Beverage Production
  • Process Connection
  • Pg 13.5 Thread
  • Reference System
  • Pre-pressurized liquid electrolyte, ceramic diaphragm, Argenthal cartridge with silver-ion trap
  • Refillable Electrolyte
  • No
  • Sensor Length
  • 120 mm
  • Shaft Material
  • Food-grade PEEK
  • Sterilizable/Autoclavable
  • No
  • Temperature Sensor
  • Digital
METL30389701 pH Sensor InPro X1 HLS-N200-K225 Special offer 
Add to Cart
  • Cable Connector
  • K8S
  • Certificates & Approvals
  • CE METTLER TOLEDO Quality Certificate FM: IS Cl. I, II, III, Div 1, GR ABCDEFG/T6 EHEDG EC1935/2004 ATEX/IECEx: Ex ia IIC T6/T5/T4/T3 Ga/Gb 3A PED
  • Connection
  • Pg 13.5 Thread
  • Hazardous Area Approvals
  • Yes
  • Hygienic/Biocompatibility Approvals
  • Yes
  • ISM (Digital) or Analog
  • ISM (Digital)
  • Measurement Parameter
  • pH
  • Model Family
  • InPro X1 HLS
  • Operating Pressure (Bar)
  • 0 to 4 barg
  • Operating Pressure (PSI)
  • 0 to 58 psig
  • Operating Temperature (Celsius)
  • 0 °C - 80 °C
  • Operating Temperature (Fahrenheit)
  • 32 °F - 176 °F
  • pH Range
  • 0 – 14
  • pH Sensing Technology
  • Composite X-Chip
  • Primary Media/Application
  • Food/Beverage Production
  • Process Connection
  • Pg 13.5 Thread
  • Reference System
  • Pre-pressurized liquid electrolyte, ceramic diaphragm, Argenthal cartridge with silver-ion trap
  • Refillable Electrolyte
  • No
  • Sensor Length
  • 225 mm
  • Shaft Material
  • Food-grade PEEK
  • Sterilizable/Autoclavable
  • No
  • Temperature Sensor
  • Digital
METL30129734 DO Sensor InPro6860i/12/120/mA Ex Special offer 
Add to Cart
  • Cable Connector
  • VP6 / VP8 (analog / digital)
  • Certificates & Approvals
  • Quality certificate, Material certificate 3.1, Surface finish certificate, ATEX/IECEx certificate, FDA/USP Class IV
  • Connection
  • Pg 13.5
  • Hazardous Area Approvals
  • ATEX/IECEx: II 1/2G Ex ia/ib HC T6 Ga/Gb II1/2D Ex ia/ib nie T83 °C Da/Db
  • Hygienic/Biocompatibility Approvals
  • FDA/USP Class 7
  • ISM (Digital) or Analog
  • ISM (Digital)
  • Measured Pressure Resistance
  • 0 psi – 87 psi (0 bar – 6 bar)
  • Measurement Parameter
  • Oxygen
  • Measurement range
  • 0...saturation
  • Measuring Temp. Range
  • 41 °F – 140 °F (5 °C – 60 °C)
  • Model Family
  • InPro 6860i
  • Operating Pressure (Bar)
  • 0.2–6 Bar
  • Operating Pressure (PSI)
  • 0–87 PSI
  • Primary Media/Application
  • Pharmaceutical/Life Science Production
  • Process Connection
  • Pg 13.5
  • Sensor Length
  • 120 mm
  • Sterilizable/Autoclavable
  • Yes
  • Temp. Range
  • 41 °F – 140 °F (5 °C – 60 °C)
METL30129735 DO Sensor InPro6860i/12/220/mA Ex Special offer 
Add to Cart
  • Cable Connector
  • VP6 / VP8 (analog / digital)
  • Certificates & Approvals
  • Quality certificate, Material certificate 3.1, Surface finish certificate, ATEX/IECEx certificate, FDA/USP Class IV
  • Connection
  • Pg 13.5
  • Hazardous Area Approvals
  • ATEX/IECEx: II 1/2G Ex ia/ib HC T6 Ga/Gb II1/2D Ex ia/ib nie T83 °C Da/Db
  • Hygienic/Biocompatibility Approvals
  • FDA/USP Class 7
  • ISM (Digital) or Analog
  • ISM (Digital)
  • Measured Pressure Resistance
  • 0 psi – 87 psi (0 bar – 6 bar)
  • Measurement Parameter
  • Oxygen
  • Measurement range
  • 0...saturation
  • Measuring Temp. Range
  • 41 °F – 140 °F (5 °C – 60 °C)
  • Model Family
  • InPro 6860i
  • Operating Pressure (Bar)
  • 0.2–6 Bar
  • Operating Pressure (PSI)
  • 0–87 PSI
  • Primary Media/Application
  • Pharmaceutical/Life Science Production
  • Process Connection
  • Pg 13.5
  • Sensor Length
  • 220 mm
  • Sterilizable/Autoclavable
  • Yes
  • Temp. Range
  • 41 °F – 140 °F (5 °C – 60 °C)
METL30129736 DO Sensor InPro6860i/12/320/mA Ex Special offer 
Add to Cart
  • Cable Connector
  • VP6 / VP8 (analog / digital)
  • Certificates & Approvals
  • Quality certificate, Material certificate 3.1, Surface finish certificate, ATEX/IECEx certificate, FDA/USP Class IV
  • Connection
  • Pg 13.5
  • Hazardous Area Approvals
  • ATEX/IECEx: II 1/2G Ex ia/ib HC T6 Ga/Gb II1/2D Ex ia/ib nie T83 °C Da/Db
  • Hygienic/Biocompatibility Approvals
  • FDA/USP Class 7
  • ISM (Digital) or Analog
  • ISM (Digital)
  • Measurement Parameter
  • Oxygen
  • Measurement range
  • 0...saturation
  • Measuring Temp. Range
  • 41 °F – 140 °F (5 °C – 60 °C)
  • Model Family
  • InPro 6860i
  • Operating Pressure (Bar)
  • 0.2–6 Bar
  • Operating Pressure (PSI)
  • 0–87 PSI
  • Primary Media/Application
  • Pharmaceutical/Life Science Production
  • Process Connection
  • Pg 13.5
  • Sensor Length
  • 320 mm
  • Sterilizable/Autoclavable
  • Yes
  • Temp. Range
  • 41 °F – 140 °F (5 °C – 60 °C)
METL30129737 DO Sensor InPro6860i/12/420/mA Ex Special offer 
Add to Cart
  • Cable Connector
  • VP6 / VP8 (analog / digital)
  • Certificates & Approvals
  • Quality certificate, Material certificate 3.1, Surface finish certificate, ATEX/IECEx certificate, FDA/USP Class IV
  • Connection
  • Pg 13.5
  • Hazardous Area Approvals
  • ATEX/IECEx: II 1/2G Ex ia/ib HC T6 Ga/Gb II1/2D Ex ia/ib nie T83 °C Da/Db
  • Hygienic/Biocompatibility Approvals
  • FDA/USP Class 7
  • ISM (Digital) or Analog
  • ISM (Digital)
  • Measurement Parameter
  • Oxygen
  • Measurement range
  • 0...saturation
  • Measuring Temp. Range
  • 41 °F – 140 °F (5 °C – 60 °C)
  • Model Family
  • InPro 6860i
  • Operating Pressure (Bar)
  • 0.2–6 Bar
  • Operating Pressure (PSI)
  • 0–87 PSI
  • Primary Media/Application
  • Pharmaceutical/Life Science Production
  • Process Connection
  • Pg 13.5
  • Sensor Length
  • 420 mm
  • Sterilizable/Autoclavable
  • Yes
  • Temp. Range
  • 41 °F – 140 °F (5 °C – 60 °C)
METL30014100 DO Sensor InPro6860i/12/120/nA Special offer 
Add to Cart
  • Cable Connector
  • VP6 / VP8 (analog / digital)
  • Certificates & Approvals
  • Quality certificate, Material certificate 3.1, Surface finish certificate, ATEX/IECEx certificate, FDA/USP Class IV
  • Connection
  • Pg 13.5
  • Hazardous Area Approvals
  • ATEX/IECEx: II 1/2G Ex ia/ib HC T6 Ga/Gb II1/2D Ex ia/ib nie T83 °C Da/Db
  • Hygienic/Biocompatibility Approvals
  • FDA/USP Class 7
  • ISM (Digital) or Analog
  • ISM (Digital)
  • Measured Pressure Resistance
  • 0 psi – 87 psi (0 bar – 6 bar)
  • Measurement Parameter
  • Oxygen
  • Measurement range
  • 0...saturation
  • Measuring Temp. Range
  • 41 °F – 140 °F (5 °C – 60 °C)
  • Model Family
  • InPro 6860i
  • Operating Pressure (Bar)
  • 0.2–6 Bar
  • Operating Pressure (PSI)
  • 0–87 PSI
  • Primary Media/Application
  • Pharmaceutical/Life Science Production
  • Process Connection
  • Pg 13.5
  • Sensor Length
  • 120 mm
  • Sterilizable/Autoclavable
  • Yes
  • Temp. Range
  • 41 °F – 140 °F (5 °C – 60 °C)
METL30014101 DO Sensor InPro6860i/12/220/nA Special offer 
Add to Cart
  • Cable Connector
  • VP6 / VP8 (analog / digital)
  • Certificates & Approvals
  • Quality certificate, Material certificate 3.1, Surface finish certificate, ATEX/IECEx certificate, FDA/USP Class IV
  • Connection
  • Pg 13.5
  • Hazardous Area Approvals
  • ATEX/IECEx: II 1/2G Ex ia/ib HC T6 Ga/Gb II1/2D Ex ia/ib nie T83 °C Da/Db
  • Hygienic/Biocompatibility Approvals
  • FDA/USP Class 7
  • ISM (Digital) or Analog
  • ISM (Digital)
  • Measured Pressure Resistance
  • 0 psi – 87 psi (0 bar – 6 bar)
  • Measurement Parameter
  • Oxygen
  • Measurement range
  • 0...saturation
  • Measuring Temp. Range
  • 41 °F – 140 °F (5 °C – 60 °C)
  • Model Family
  • InPro 6860i
  • Operating Pressure (Bar)
  • 0.2–6 Bar
  • Operating Pressure (PSI)
  • 0–87 PSI
  • Primary Media/Application
  • Pharmaceutical/Life Science Production
  • Process Connection
  • Pg 13.5
  • Sensor Length
  • 220 mm
  • Sterilizable/Autoclavable
  • Yes
  • Temp. Range
  • 41 °F – 140 °F (5 °C – 60 °C)
METL30014102 DO Sensor InPro6860i/12/320/nA Special offer 
Add to Cart
  • Cable Connector
  • VP6 / VP8 (analog / digital)
  • Certificates & Approvals
  • Quality certificate, Material certificate 3.1, Surface finish certificate, ATEX/IECEx certificate, FDA/USP Class IV
  • Connection
  • Pg 13.5
  • Hazardous Area Approvals
  • ATEX/IECEx: II 1/2G Ex ia/ib HC T6 Ga/Gb II1/2D Ex ia/ib nie T83 °C Da/Db
  • Hygienic/Biocompatibility Approvals
  • FDA/USP Class 7
  • ISM (Digital) or Analog
  • ISM (Digital)
  • Measured Pressure Resistance
  • 0 psi – 87 psi (0 bar – 6 bar)
  • Measurement Parameter
  • Oxygen
  • Measurement range
  • 0...saturation
  • Measuring Temp. Range
  • 41 °F – 140 °F (5 °C – 60 °C)
  • Model Family
  • InPro 6860i
  • Operating Pressure (Bar)
  • 0.2–6 Bar
  • Operating Pressure (PSI)
  • 0–87 PSI
  • Primary Media/Application
  • Pharmaceutical/Life Science Production
  • Process Connection
  • Pg 13.5
  • Sensor Length
  • 320 mm
  • Sterilizable/Autoclavable
  • Yes
  • Temp. Range
  • 41 °F – 140 °F (5 °C – 60 °C)