+852-3069 6950
css@gugent.com.hk
 

Lab filtration products

Your proven partner for laboratory filtration, separation and purification.


Catalog No. Product Net Price
CYT28420115 HEPA-CAP 75, inlet 3/8 to 1/2 136.5 
Add to Cart
  • Pack size
  • 5 pieces
  • Dimensions
  • 36 mm
  • Operating pressure max.
  • 4.1 bar (60 psi)
  • Operating Temperature
  • Ambient
  • Filter Media
  • Glass microfiber (GMF)
  • Biosafety
  • Materials pass USP Class VI
  • Flow Direction
  • Bidirectional
  • Sterilization
  • Autoclavable: 121ºC (250ºF) for 20 minutes at 0.1 MPa (1.0 bar, 15 psi)
  • Sealing
  • Heat-fused
  • Support System
  • Polypropylene (PP)
  • Particle retention
  • 99.97% retention of all particles ≥ 0.3 μm
  • Housing and support
  • Polypropylene (PP)
  • Maximum operating pressure
  • 0.41 MPa (4.1 bar, 60 psi)
CYT28420116 HEPA-CAP 150, inlet 3/8 147 
Add to Cart
  • Pack size
  • 5 pieces
  • Dimensions
  • 36 mm
  • Operating pressure max.
  • 4.1 bar (60 psi)
  • Operating Temperature
  • Ambient
  • Filter Media
  • Glass microfiber (GMF)
  • Biosafety
  • Materials pass USP Class VI
  • Flow Direction
  • Bidirectional
  • Sterilization
  • Autoclavable: 121ºC (250ºF) for 20 minutes at 0.1 MPa (1.0 bar, 15 psi)
  • Sealing
  • Heat-fused
  • Support System
  • Polypropylene (PP)
  • Particle retention
  • 99.97% retention of all particles ≥ 0.3 μm
  • Housing and support
  • Polypropylene (PP)
  • Maximum operating pressure
  • 0.41 MPa (4.1 bar, 60 psi)
CYT28418912 HEPA-CAP 36, inlet 3/8 465 
Add to Cart
  • Pack size
  • 5 pieces
  • Dimensions
  • 36 mm
  • Operating pressure max.
  • 4.1 bar (60 psi)
  • Operating Temperature
  • Ambient
  • Filter Media
  • Glass microfiber (GMF)
  • Biosafety
  • Materials pass USP Class VI
  • Flow Direction
  • Bidirectional
  • Sterilization
  • Autoclavable: 121ºC (250ºF) for 20 minutes at 0.1 MPa (1.0 bar, 15 psi)
  • Sealing
  • Heat-fused
  • Support System
  • Polypropylene (PP)
  • Particle retention
  • 99.97% retention of all particles ≥ 0.3 μm
  • Housing and support
  • Polypropylene (PP)
  • Maximum operating pressure
  • 0.41 MPa (4.1 bar, 60 psi)
CYT28419003 HEPA-CAP 150, inlet 3/8 513 
Add to Cart
  • Pack size
  • 5 pieces
  • Dimensions
  • 36 mm
  • Operating pressure max.
  • 4.1 bar (60 psi)
  • Operating Temperature
  • Ambient
  • Filter Media
  • Glass microfiber (GMF)
  • Biosafety
  • Materials pass USP Class VI
  • Flow Direction
  • Bidirectional
  • Sterilization
  • Autoclavable: 121ºC (250ºF) for 20 minutes at 0.1 MPa (1.0 bar, 15 psi)
  • Sealing
  • Heat-fused
  • Support System
  • Polypropylene (PP)
  • Particle retention
  • 99.97% retention of all particles ≥ 0.3 μm
  • Housing and support
  • Polypropylene (PP)
  • Maximum operating pressure
  • 0.41 MPa (4.1 bar, 60 psi)
CYT28418946 HEPA-CAP 75, inlet 3/8 841.5 
Add to Cart
  • Pack size
  • 5 pieces
  • Dimensions
  • 36 mm
  • Operating pressure max.
  • 4.1 bar (60 psi)
  • Operating Temperature
  • Ambient
  • Filter Media
  • Glass microfiber (GMF)
  • Biosafety
  • Materials pass USP Class VI
  • Flow Direction
  • Bidirectional
  • Sterilization
  • Autoclavable: 121ºC (250ºF) for 20 minutes at 0.1 MPa (1.0 bar, 15 psi)
  • Sealing
  • Heat-fused
  • Support System
  • Polypropylene (PP)
  • Particle retention
  • 99.97% retention of all particles ≥ 0.3 μm
  • Housing and support
  • Polypropylene (PP)
  • Maximum operating pressure
  • 0.41 MPa (4.1 bar, 60 psi)
CYT28415043 Mixed Cellulose Ester Filter, ME Range (ME 24), plain, 0.2 135 
Add to Cart
  • Material
  • Mixed Cellulose Ester (MCE)
  • Autoclavable
  • Yes
  • Application
  • The membrane is particularly effective in applications requiring higher flow rates and larger volume filtration including clarification or sterilization of aqueous solutions, particulate analysis and removal, air monitoring and microbial analysis. Other applications include:\nClarification or sterilization of aqueous solutions\nCytology\nAir monitoring\nHPLC samples (aqueous)\nVirus concentration\nParticulate analysis\nBiological assays\nFood microbiology including enumeration of E. coli in foods\nBacteriological studies\nParticle counting from liquids and aerosols\nYeasts and molds.
  • Operating temp. max.
  • 130°C
  • Diameter
  • 25 mm
  • Pore Size
  • 0.2
  • Membrane Type
  • ME 24
  • Porosity Max.
  • 77%
  • Porosity Min.
  • 74%
  • Protein Binding
  • Medium
  • Solvent Resistance
  • Medium
  • Sterility
  • Nonsterile
  • Water Flow Rate (Delta p equals 0.9 bar)
  • 20 s/100 ml/12.5 cm²
  • Weight Max.
  • 5.0 mg/cm²
  • Weight Min.
  • 4.3 mg/cm²
  • Grid Color
  • Plain
  • Grid Dimension
  • plain
  • Interleaving Paper
  • Yes
CYT28415044 Mixed Cellulose Ester Filter, ME Range (ME 24), plain, 0.2 184.5 
Add to Cart
  • Material
  • Mixed Cellulose Ester (MCE)
  • Autoclavable
  • Yes
  • Application
  • The membrane is particularly effective in applications requiring higher flow rates and larger volume filtration including clarification or sterilization of aqueous solutions, particulate analysis and removal, air monitoring and microbial analysis. Other applications include:\nClarification or sterilization of aqueous solutions\nCytology\nAir monitoring\nHPLC samples (aqueous)\nVirus concentration\nParticulate analysis\nBiological assays\nFood microbiology including enumeration of E. coli in foods\nBacteriological studies\nParticle counting from liquids and aerosols\nYeasts and molds.
  • Operating temp. max.
  • 130°C
  • Diameter
  • 25 mm
  • Pore Size
  • 0.2
  • Membrane Type
  • ME 24
  • Porosity Max.
  • 77%
  • Porosity Min.
  • 74%
  • Protein Binding
  • Medium
  • Solvent Resistance
  • Medium
  • Sterility
  • Nonsterile
  • Water Flow Rate (Delta p equals 0.9 bar)
  • 20 s/100 ml/12.5 cm²
  • Weight Max.
  • 5.0 mg/cm²
  • Weight Min.
  • 4.3 mg/cm²
  • Grid Color
  • Plain
  • Grid Dimension
  • plain
  • Interleaving Paper
  • Yes
CYT28415045 Mixed Cellulose Ester Filter, ME Range (ME 24), plain, 0.2 189 
Add to Cart
  • Material
  • Mixed Cellulose Ester (MCE)
  • Autoclavable
  • Yes
  • Application
  • The membrane is particularly effective in applications requiring higher flow rates and larger volume filtration including clarification or sterilization of aqueous solutions, particulate analysis and removal, air monitoring and microbial analysis. Other applications include:\nClarification or sterilization of aqueous solutions\nCytology\nAir monitoring\nHPLC samples (aqueous)\nVirus concentration\nParticulate analysis\nBiological assays\nFood microbiology including enumeration of E. coli in foods\nBacteriological studies\nParticle counting from liquids and aerosols\nYeasts and molds.
  • Operating temp. max.
  • 130°C
  • Diameter
  • 25 mm
  • Pore Size
  • 0.2
  • Membrane Type
  • ME 24
  • Porosity Max.
  • 77%
  • Porosity Min.
  • 74%
  • Protein Binding
  • Medium
  • Solvent Resistance
  • Medium
  • Sterility
  • Nonsterile
  • Water Flow Rate (Delta p equals 0.9 bar)
  • 20 s/100 ml/12.5 cm²
  • Weight Max.
  • 5.0 mg/cm²
  • Weight Min.
  • 4.3 mg/cm²
  • Grid Color
  • Plain
  • Grid Dimension
  • plain
  • Interleaving Paper
  • Yes
CYT28415048 Mixed Cellulose Ester Filter, ME Range (ME 24), plain, 0.2 219 
Add to Cart
  • Material
  • Mixed Cellulose Ester (MCE)
  • Autoclavable
  • Yes
  • Application
  • The membrane is particularly effective in applications requiring higher flow rates and larger volume filtration including clarification or sterilization of aqueous solutions, particulate analysis and removal, air monitoring and microbial analysis. Other applications include:\nClarification or sterilization of aqueous solutions\nCytology\nAir monitoring\nHPLC samples (aqueous)\nVirus concentration\nParticulate analysis\nBiological assays\nFood microbiology including enumeration of E. coli in foods\nBacteriological studies\nParticle counting from liquids and aerosols\nYeasts and molds.
  • Operating temp. max.
  • 130°C
  • Diameter
  • 25 mm
  • Pore Size
  • 0.2
  • Membrane Type
  • ME 24
  • Porosity Max.
  • 77%
  • Porosity Min.
  • 74%
  • Protein Binding
  • Medium
  • Solvent Resistance
  • Medium
  • Sterility
  • Nonsterile
  • Water Flow Rate (Delta p equals 0.9 bar)
  • 20 s/100 ml/12.5 cm²
  • Weight Max.
  • 5.0 mg/cm²
  • Weight Min.
  • 4.3 mg/cm²
  • Grid Color
  • Plain
  • Grid Dimension
  • plain
  • Interleaving Paper
  • Yes
CYT28415047 Mixed Cellulose Ester Filter, ME Range (ME 24), plain, 0.2 487.5 
Add to Cart
  • Material
  • Mixed Cellulose Ester (MCE)
  • Autoclavable
  • Yes
  • Application
  • The membrane is particularly effective in applications requiring higher flow rates and larger volume filtration including clarification or sterilization of aqueous solutions, particulate analysis and removal, air monitoring and microbial analysis. Other applications include:\nClarification or sterilization of aqueous solutions\nCytology\nAir monitoring\nHPLC samples (aqueous)\nVirus concentration\nParticulate analysis\nBiological assays\nFood microbiology including enumeration of E. coli in foods\nBacteriological studies\nParticle counting from liquids and aerosols\nYeasts and molds.
  • Operating temp. max.
  • 130°C
  • Diameter
  • 25 mm
  • Pore Size
  • 0.2
  • Membrane Type
  • ME 24
  • Porosity Max.
  • 77%
  • Porosity Min.
  • 74%
  • Protein Binding
  • Medium
  • Solvent Resistance
  • Medium
  • Sterility
  • Nonsterile
  • Water Flow Rate (Delta p equals 0.9 bar)
  • 20 s/100 ml/12.5 cm²
  • Weight Max.
  • 5.0 mg/cm²
  • Weight Min.
  • 4.3 mg/cm²
  • Grid Color
  • Plain
  • Grid Dimension
  • plain
  • Interleaving Paper
  • Yes

Overview

Capsule filters


Cellulose filter papers

Cellulose filter papers used for general filtration and exhibiting particle retention levels down to 2.5 µm.


Centrifugal devices


Filter Plates

Cytiva filter plates offer a selection of membranes, sample well volumes, and tip configurations allowing researchers to select the right plate for their high throughput application while complying with ANSI/SLAS standards for use in robotic systems.


Glass and quartz microfiber filter

Glass and quartz microfiber filter papers for your filtration workflow.


Immunodiagnostics

Pads and membranes for lateral flow, flow through, blotting, and dipstick assays.


Syringeless filters


Syringe filters - non-sterile


Syringe filters - sterile


Tangential flow filtration for labscale


Thimbles

Cellulose, glass, and quartz thimbles for your filtration workflow.





Resources