+852-3069 6950
css@gugent.com.hk
 

Lab filtration products

Your proven partner for laboratory filtration, separation and purification.


Catalog No. Product Net Price
CYT28418489 Grade 934-AH Filter for Total Suspended Solids Analysis, 8 USD 597 
Add to Cart
  • Format
  • Circles
  • Dimensions
  • Ø 21 mm
  • Material
  • Borosilicate glass
  • Application
  • Used for determining total suspended solids in water, removal of turbidity and filtration of bacterial cultures\nUsed for a wide range of laboratory applications.\nIt is recommended for water pollution monitoring, cell harvesting, liquid scintillation counting and air pollution monitoring.
  • Diameter
  • 21
  • Grade
  • Grade 934-AH
  • Typical Particle Retention in Liquid
  • 1.5 µm
  • Nominal thickness
  • 435
  • Typical water flow rate
  • 341 ml/min
  • Nominal basis weight
  • 64
  • Nominal air flow rate
  • 3.7 s/100 ml/in²
CYT28418485 Grade 934-AH Filter for Total Suspended Solids Analysis, 240 mm circle (100 pcs) USD 777 
Add to Cart
  • Format
  • Circles
  • Dimensions
  • Ø 21 mm
  • Material
  • Borosilicate glass
  • Application
  • Used for determining total suspended solids in water, removal of turbidity and filtration of bacterial cultures\nUsed for a wide range of laboratory applications.\nIt is recommended for water pollution monitoring, cell harvesting, liquid scintillation counting and air pollution monitoring.
  • Diameter
  • 21
  • Grade
  • Grade 934-AH
  • Typical Particle Retention in Liquid
  • 1.5 µm
  • Nominal thickness
  • 435
  • Typical water flow rate
  • 341 ml/min
  • Nominal basis weight
  • 64
  • Nominal air flow rate
  • 3.7 s/100 ml/in²
CYT28418490 Grade 934-AH Filter for Total Suspended Solids Analysis, 12 USD 1,031 
Add to Cart
  • Format
  • Circles
  • Dimensions
  • Ø 21 mm
  • Material
  • Borosilicate glass
  • Application
  • Used for determining total suspended solids in water, removal of turbidity and filtration of bacterial cultures\nUsed for a wide range of laboratory applications.\nIt is recommended for water pollution monitoring, cell harvesting, liquid scintillation counting and air pollution monitoring.
  • Diameter
  • 21
  • Grade
  • Grade 934-AH
  • Typical Particle Retention in Liquid
  • 1.5 µm
  • Nominal thickness
  • 435
  • Typical water flow rate
  • 341 ml/min
  • Nominal basis weight
  • 64
  • Nominal air flow rate
  • 3.7 s/100 ml/in²
CYT28418486 Grade 934-AH Filter for Total Suspended Solids Analysis, 320 mm circle (100 pcs) USD 1,311 
Add to Cart
  • Format
  • Circles
  • Dimensions
  • Ø 21 mm
  • Material
  • Borosilicate glass
  • Application
  • Used for determining total suspended solids in water, removal of turbidity and filtration of bacterial cultures\nUsed for a wide range of laboratory applications.\nIt is recommended for water pollution monitoring, cell harvesting, liquid scintillation counting and air pollution monitoring.
  • Diameter
  • 21
  • Grade
  • Grade 934-AH
  • Typical Particle Retention in Liquid
  • 1.5 µm
  • Nominal thickness
  • 435
  • Typical water flow rate
  • 341 ml/min
  • Nominal basis weight
  • 64
  • Nominal air flow rate
  • 3.7 s/100 ml/in²
CYT28418491 Grade 934-AH Filter for Total Suspended Solids Analysis, 19 USD 2,967 
Add to Cart
  • Format
  • Circles
  • Dimensions
  • Ø 21 mm
  • Material
  • Borosilicate glass
  • Application
  • Used for determining total suspended solids in water, removal of turbidity and filtration of bacterial cultures\nUsed for a wide range of laboratory applications.\nIt is recommended for water pollution monitoring, cell harvesting, liquid scintillation counting and air pollution monitoring.
  • Diameter
  • 21
  • Grade
  • Grade 934-AH
  • Typical Particle Retention in Liquid
  • 1.5 µm
  • Nominal thickness
  • 435
  • Typical water flow rate
  • 341 ml/min
  • Nominal basis weight
  • 64
  • Nominal air flow rate
  • 3.7 s/100 ml/in²
CYT29170582 Grade GF 10 Glass Filter with Organic Binder 35 mm USD 47 
Add to Cart
  • Format
  • Circles
  • Dimensions
  • Ø 50 mm
  • Material
  • Borosilicate glass
  • Operating Temperature
  • <180 °C
  • Application
  • Used as a weighing aid for infrared weighing and as a roll filter in automatic air filtration units.
  • Grade
  • Grade GF 10
CYT29093241 Grade GF 10 Glass Filter with Organic Binder 40 mm USD 51 
Add to Cart
  • Format
  • Circles
  • Dimensions
  • Ø 50 mm
  • Material
  • Borosilicate glass
  • Operating Temperature
  • <180 °C
  • Application
  • Used as a weighing aid for infrared weighing and as a roll filter in automatic air filtration units.
  • Grade
  • Grade GF 10
CYT28414800 Grade GF 10 Glass Filter with Organic Binder 35 mm USD 81 
Add to Cart
  • Format
  • Circles
  • Dimensions
  • Ø 50 mm
  • Material
  • Borosilicate glass
  • Operating Temperature
  • <180 °C
  • Application
  • Used as a weighing aid for infrared weighing and as a roll filter in automatic air filtration units.
  • Grade
  • Grade GF 10
CYT28414797 Grade GF 10 Glass Filter with Organic Binder 30 mm USD 107 
Add to Cart
  • Format
  • Circles
  • Dimensions
  • Ø 50 mm
  • Material
  • Borosilicate glass
  • Operating Temperature
  • <180 °C
  • Application
  • Used as a weighing aid for infrared weighing and as a roll filter in automatic air filtration units.
  • Grade
  • Grade GF 10
CYT28414801 Grade GF 10 Glass Filter with Organic Binder, 40 mm x 42 m (1 pc) USD 116 
Add to Cart
  • Format
  • Circles
  • Dimensions
  • Ø 50 mm
  • Material
  • Borosilicate glass
  • Operating Temperature
  • <180 °C
  • Application
  • Used as a weighing aid for infrared weighing and as a roll filter in automatic air filtration units.
  • Grade
  • Grade GF 10

Overview

Capsule filters


Cellulose filter papers

Cellulose filter papers used for general filtration and exhibiting particle retention levels down to 2.5 µm.


Centrifugal devices


Filter Plates

Cytiva filter plates offer a selection of membranes, sample well volumes, and tip configurations allowing researchers to select the right plate for their high throughput application while complying with ANSI/SLAS standards for use in robotic systems.


Glass and quartz microfiber filter

Glass and quartz microfiber filter papers for your filtration workflow.


Immunodiagnostics

Pads and membranes for lateral flow, flow through, blotting, and dipstick assays.


Syringeless filters


Syringe filters - non-sterile


Syringe filters - sterile


Tangential flow filtration for labscale


Thimbles

Cellulose, glass, and quartz thimbles for your filtration workflow.





Resources