+852-3069 6950
css@gugent.com.hk
 

Lab filtration products

Your proven partner for laboratory filtration, separation and purification.


Catalog No. Product Net Price
CYT29028447 Mini-UniPrep G2 Syringeless Filters, std cap, translucent housing, 0.2 6381 
Add to Cart
  • Pack size
  • 100 pieces
  • Dimensions
  • Equivalent in size to 12 x 32 mm vials. Will fit any autosampler that accommodates standard 12 mm x 32mm profile vials\n(Needle height of the autosampler may need adjusting)
  • Material
  • Chamber: Borosilicate Glass\nPlunger Outer Housing: Polypropylene\nPlunger Inner Storage Vial: Borosilicate Glass\nFilter media: As Specified\nSepta: Silicone with PTFE Liner\nCap: Polypropylene
  • Application
  • Routine UHPLC/HPLC analysis.\nComposite assays.\nContent uniformity testing.\nProtein precipitation.\nSolubility testing.\nDissolution testing.\nSample filtration.\nUse with any compound that requires protection from light, such as catecholamines or vitamins.
  • Housing
  • Borosilicate glass and Polypropylene (PP)
  • Pore Size
  • 0.2 µm
  • Color
  • Amber
  • Capacity Max.
  • Chamber (Unfiltered Sample): 500 μl; Inner Storage Vial (Filtered Sample) : 330 μl; Recommended Minimum Filtering Volume: 220 μl placed in the Chamber to obtain 50 μl in Inner Storage Vial
  • Filtration Media
  • Polyvinylidene Difluoride (PVDF)
CYT29028466 Mini-UniPrep G2 Syringeless Filters, std cap, translucent housing, 0.2 6381 
Add to Cart
  • Pack size
  • 100 pieces
  • Dimensions
  • Equivalent in size to 12 x 32 mm vials. Will fit any autosampler that accommodates standard 12 mm x 32mm profile vials\n(Needle height of the autosampler may need adjusting)
  • Material
  • Chamber: Borosilicate Glass\nPlunger Outer Housing: Polypropylene\nPlunger Inner Storage Vial: Borosilicate Glass\nFilter media: As Specified\nSepta: Silicone with PTFE Liner\nCap: Polypropylene
  • Application
  • Routine UHPLC/HPLC analysis.\nComposite assays.\nContent uniformity testing.\nProtein precipitation.\nSolubility testing.\nDissolution testing.\nSample filtration.\nUse with any compound that requires protection from light, such as catecholamines or vitamins.
  • Housing
  • Borosilicate glass and Polypropylene (PP)
  • Pore Size
  • 0.2 µm
  • Color
  • Amber
  • Capacity Max.
  • Chamber (Unfiltered Sample): 500 μl; Inner Storage Vial (Filtered Sample) : 330 μl; Recommended Minimum Filtering Volume: 220 μl placed in the Chamber to obtain 50 μl in Inner Storage Vial
  • Filtration Media
  • Polyvinylidene Difluoride (PVDF)
CYT29030637 Mini-UniPrep G2 Syringeless Filters, std cap, translucent housing, 0.45 6381 
Add to Cart
  • Pack size
  • 100 pieces
  • Dimensions
  • Equivalent in size to 12 x 32 mm vials. Will fit any autosampler that accommodates standard 12 mm x 32mm profile vials\n(Needle height of the autosampler may need adjusting)
  • Material
  • Chamber: Borosilicate Glass\nPlunger Outer Housing: Polypropylene\nPlunger Inner Storage Vial: Borosilicate Glass\nFilter media: As Specified\nSepta: Silicone with PTFE Liner\nCap: Polypropylene
  • Application
  • Routine UHPLC/HPLC analysis.\nComposite assays.\nContent uniformity testing.\nProtein precipitation.\nSolubility testing.\nDissolution testing.\nSample filtration.\nUse with any compound that requires protection from light, such as catecholamines or vitamins.
  • Housing
  • Borosilicate glass and Polypropylene (PP)
  • Pore Size
  • 0.2 µm
  • Color
  • Amber
  • Capacity Max.
  • Chamber (Unfiltered Sample): 500 μl; Inner Storage Vial (Filtered Sample) : 330 μl; Recommended Minimum Filtering Volume: 220 μl placed in the Chamber to obtain 50 μl in Inner Storage Vial
  • Filtration Media
  • Polyvinylidene Difluoride (PVDF)
CYT29030650 Mini-UniPrep G2 Syringeless Filters, std cap, translucent housing, 0.45 6381 
Add to Cart
  • Pack size
  • 100 pieces
  • Dimensions
  • Equivalent in size to 12 x 32 mm vials. Will fit any autosampler that accommodates standard 12 mm x 32mm profile vials\n(Needle height of the autosampler may need adjusting)
  • Material
  • Chamber: Borosilicate Glass\nPlunger Outer Housing: Polypropylene\nPlunger Inner Storage Vial: Borosilicate Glass\nFilter media: As Specified\nSepta: Silicone with PTFE Liner\nCap: Polypropylene
  • Application
  • Routine UHPLC/HPLC analysis.\nComposite assays.\nContent uniformity testing.\nProtein precipitation.\nSolubility testing.\nDissolution testing.\nSample filtration.\nUse with any compound that requires protection from light, such as catecholamines or vitamins.
  • Housing
  • Borosilicate glass and Polypropylene (PP)
  • Pore Size
  • 0.2 µm
  • Color
  • Amber
  • Capacity Max.
  • Chamber (Unfiltered Sample): 500 μl; Inner Storage Vial (Filtered Sample) : 330 μl; Recommended Minimum Filtering Volume: 220 μl placed in the Chamber to obtain 50 μl in Inner Storage Vial
  • Filtration Media
  • Polyvinylidene Difluoride (PVDF)
CYT29026059 Mini-UniPrep G2 Syringeless Filters, slit septum cap, translucent housing, 0.2 μm PTFE (1000 pcs) 6682.5 
Add to Cart
  • Pack size
  • 100 pieces
  • Dimensions
  • Equivalent in size to 12 x 32 mm vials. Will fit any autosampler that accommodates standard 12 mm x 32mm profile vials\n(Needle height of the autosampler may need adjusting)
  • Material
  • Chamber: Borosilicate Glass\nPlunger Outer Housing: Polypropylene\nPlunger Inner Storage Vial: Borosilicate Glass\nFilter media: As Specified\nSepta: Silicone with PTFE Liner\nCap: Polypropylene
  • Application
  • Routine UHPLC/HPLC analysis.\nComposite assays.\nContent uniformity testing.\nProtein precipitation.\nSolubility testing.\nDissolution testing.\nSample filtration.\nUse with any compound that requires protection from light, such as catecholamines or vitamins.
  • Housing
  • Borosilicate glass and Polypropylene (PP)
  • Pore Size
  • 0.2 µm
  • Color
  • Amber
  • Capacity Max.
  • Chamber (Unfiltered Sample): 500 μl; Inner Storage Vial (Filtered Sample) : 330 μl; Recommended Minimum Filtering Volume: 220 μl placed in the Chamber to obtain 50 μl in Inner Storage Vial
  • Filtration Media
  • Polyvinylidene Difluoride (PVDF)
CYT29026061 Mini-UniPrep G2 Syringeless Filters, slit septum cap, translucent housing, 0.45 μm PTFE (1000 pcs) 6682.5 
Add to Cart
  • Pack size
  • 100 pieces
  • Dimensions
  • Equivalent in size to 12 x 32 mm vials. Will fit any autosampler that accommodates standard 12 mm x 32mm profile vials\n(Needle height of the autosampler may need adjusting)
  • Material
  • Chamber: Borosilicate Glass\nPlunger Outer Housing: Polypropylene\nPlunger Inner Storage Vial: Borosilicate Glass\nFilter media: As Specified\nSepta: Silicone with PTFE Liner\nCap: Polypropylene
  • Application
  • Routine UHPLC/HPLC analysis.\nComposite assays.\nContent uniformity testing.\nProtein precipitation.\nSolubility testing.\nDissolution testing.\nSample filtration.\nUse with any compound that requires protection from light, such as catecholamines or vitamins.
  • Housing
  • Borosilicate glass and Polypropylene (PP)
  • Pore Size
  • 0.2 µm
  • Color
  • Amber
  • Capacity Max.
  • Chamber (Unfiltered Sample): 500 μl; Inner Storage Vial (Filtered Sample) : 330 μl; Recommended Minimum Filtering Volume: 220 μl placed in the Chamber to obtain 50 μl in Inner Storage Vial
  • Filtration Media
  • Polyvinylidene Difluoride (PVDF)
CYT29028429 Mini-UniPrep G2 Syringeless Filters, slit septum cap, translucent housing, 0.2 μm nylon (1000 pcs) 6682.5 
Add to Cart
  • Pack size
  • 100 pieces
  • Dimensions
  • Equivalent in size to 12 x 32 mm vials. Will fit any autosampler that accommodates standard 12 mm x 32mm profile vials\n(Needle height of the autosampler may need adjusting)
  • Material
  • Chamber: Borosilicate Glass\nPlunger Outer Housing: Polypropylene\nPlunger Inner Storage Vial: Borosilicate Glass\nFilter media: As Specified\nSepta: Silicone with PTFE Liner\nCap: Polypropylene
  • Application
  • Routine UHPLC/HPLC analysis.\nComposite assays.\nContent uniformity testing.\nProtein precipitation.\nSolubility testing.\nDissolution testing.\nSample filtration.\nUse with any compound that requires protection from light, such as catecholamines or vitamins.
  • Housing
  • Borosilicate glass and Polypropylene (PP)
  • Pore Size
  • 0.2 µm
  • Color
  • Amber
  • Capacity Max.
  • Chamber (Unfiltered Sample): 500 μl; Inner Storage Vial (Filtered Sample) : 330 μl; Recommended Minimum Filtering Volume: 220 μl placed in the Chamber to obtain 50 μl in Inner Storage Vial
  • Filtration Media
  • Polyvinylidene Difluoride (PVDF)
CYT29028451 Mini-UniPrep G2 Syringeless Filters, slit septum cap, translucent housing, 0.2 μm PVDF (1000 pcs) 6682.5 
Add to Cart
  • Pack size
  • 100 pieces
  • Dimensions
  • Equivalent in size to 12 x 32 mm vials. Will fit any autosampler that accommodates standard 12 mm x 32mm profile vials\n(Needle height of the autosampler may need adjusting)
  • Material
  • Chamber: Borosilicate Glass\nPlunger Outer Housing: Polypropylene\nPlunger Inner Storage Vial: Borosilicate Glass\nFilter media: As Specified\nSepta: Silicone with PTFE Liner\nCap: Polypropylene
  • Application
  • Routine UHPLC/HPLC analysis.\nComposite assays.\nContent uniformity testing.\nProtein precipitation.\nSolubility testing.\nDissolution testing.\nSample filtration.\nUse with any compound that requires protection from light, such as catecholamines or vitamins.
  • Housing
  • Borosilicate glass and Polypropylene (PP)
  • Pore Size
  • 0.2 µm
  • Color
  • Amber
  • Capacity Max.
  • Chamber (Unfiltered Sample): 500 μl; Inner Storage Vial (Filtered Sample) : 330 μl; Recommended Minimum Filtering Volume: 220 μl placed in the Chamber to obtain 50 μl in Inner Storage Vial
  • Filtration Media
  • Polyvinylidene Difluoride (PVDF)
CYT29030642 Mini-UniPrep G2 Syringeless Filters, slit septum cap, translucent housing, 0.45 μm PVDF (1000 pcs) 6682.5 
Add to Cart
  • Pack size
  • 100 pieces
  • Dimensions
  • Equivalent in size to 12 x 32 mm vials. Will fit any autosampler that accommodates standard 12 mm x 32mm profile vials\n(Needle height of the autosampler may need adjusting)
  • Material
  • Chamber: Borosilicate Glass\nPlunger Outer Housing: Polypropylene\nPlunger Inner Storage Vial: Borosilicate Glass\nFilter media: As Specified\nSepta: Silicone with PTFE Liner\nCap: Polypropylene
  • Application
  • Routine UHPLC/HPLC analysis.\nComposite assays.\nContent uniformity testing.\nProtein precipitation.\nSolubility testing.\nDissolution testing.\nSample filtration.\nUse with any compound that requires protection from light, such as catecholamines or vitamins.
  • Housing
  • Borosilicate glass and Polypropylene (PP)
  • Pore Size
  • 0.2 µm
  • Color
  • Amber
  • Capacity Max.
  • Chamber (Unfiltered Sample): 500 μl; Inner Storage Vial (Filtered Sample) : 330 μl; Recommended Minimum Filtering Volume: 220 μl placed in the Chamber to obtain 50 μl in Inner Storage Vial
  • Filtration Media
  • Polyvinylidene Difluoride (PVDF)
CYT29011861 Mini-UniPrep G2 Syringeless Filters, slit septum cap, translucent housing, 0.2 μm PP (100 pcs) Special offer 
Add to Cart
  • Pack size
  • 100 pieces
  • Dimensions
  • Equivalent in size to 12 x 32 mm vials. Will fit any autosampler that accommodates standard 12 mm x 32mm profile vials\n(Needle height of the autosampler may need adjusting)
  • Material
  • Chamber: Borosilicate Glass\nPlunger Outer Housing: Polypropylene\nPlunger Inner Storage Vial: Borosilicate Glass\nFilter media: As Specified\nSepta: Silicone with PTFE Liner\nCap: Polypropylene
  • Application
  • Routine UHPLC/HPLC analysis.\nComposite assays.\nContent uniformity testing.\nProtein precipitation.\nSolubility testing.\nDissolution testing.\nSample filtration.\nUse with any compound that requires protection from light, such as catecholamines or vitamins.
  • Housing
  • Borosilicate glass and Polypropylene (PP)
  • Pore Size
  • 0.2 µm
  • Color
  • Amber
  • Capacity Max.
  • Chamber (Unfiltered Sample): 500 μl; Inner Storage Vial (Filtered Sample) : 330 μl; Recommended Minimum Filtering Volume: 220 μl placed in the Chamber to obtain 50 μl in Inner Storage Vial
  • Filtration Media
  • Polyvinylidene Difluoride (PVDF)

Overview

Capsule filters


Cellulose filter papers

Cellulose filter papers used for general filtration and exhibiting particle retention levels down to 2.5 µm.


Centrifugal devices


Filter Plates

Cytiva filter plates offer a selection of membranes, sample well volumes, and tip configurations allowing researchers to select the right plate for their high throughput application while complying with ANSI/SLAS standards for use in robotic systems.


Glass and quartz microfiber filter

Glass and quartz microfiber filter papers for your filtration workflow.


Immunodiagnostics

Pads and membranes for lateral flow, flow through, blotting, and dipstick assays.


Syringeless filters


Syringe filters - non-sterile


Syringe filters - sterile


Tangential flow filtration for labscale


Thimbles

Cellulose, glass, and quartz thimbles for your filtration workflow.





Resources