+852-3069 6950
css@gugent.com.hk
 

Lab filtration products

Your proven partner for laboratory filtration, separation and purification.


Catalog No. Product Net Price
CYT11000540 Start AXH Ultrafiltration Cartridge 396 
Add to Cart
  • Dimensions
  • 34 L x 0.8 cm o.d.
  • Autoclavable
  • No
  • Application
  • Virus concentration/purification/removal, hemoglobin concentration, virus concentration/purification/removal\nCell harvesting and washing, clarification of lysates and cell cultures, and concentration, diafiltration, and purification of monoclonal antibodies, plasmids, proteins, viruses, vaccines, colloids and plasma\nDesigned for small-scale processing, rapid laboratory concentration, and/or diafiltration of biological solutions at research-scale volumes with convenience and speed
  • Certificate of Analysis
  • Yes
  • pH Stability Short Term
  • 2–13
  • Pore Size
  • 100000 NMWC
  • Material Compliance
  • USP class VI biological test
CYT56411028 Start AXH Microfiltration Cartridge (CFP-1-E-H22U) 393 
Add to Cart
  • Pack size
  • 1
  • Dimensions
  • 60 L x 0.3 cm o.d.
  • Autoclavable
  • No
  • Application
  • Microfiltration
  • Certificate of Analysis
  • Yes
  • pH Stability Short Term
  • 2–13
  • Pore Size
  • 0.1
  • Material Compliance
  • USP XXVII class VI biological test
CYT40017027 Sentino™ Magnetic filter funnel, 150 mL, 47 mm (1/pkg) 318 
Add to Cart
  • Effective Filtration Area
  • 9.6 cm²
  • Autoclavable
  • 121 - 123 ºC (250-253 ºF) at 1.0 bar (100 kPa, 15 psi) for 15 - 20 minutes
  • Sterilization
  • UVSterilizable
  • Filter Size
  • Accepts 47 mm
  • Diameter (Imperial in)
  • 3 in
  • Diameter (Metric cm)
  • 7.6 cm
  • Funnel Capacity (Metric mL)
  • 150 mL
  • Height (Imperial in)
  • 0 in
  • Height (Metric cm)
  • 0 cm
  • Seals
  • 9.6 cm²
CYT40017987 Sentino™ Magnetic filter funnel, 300 mL, 47 mm (1/pkg) 358.5 
Add to Cart
  • Effective Filtration Area
  • 9.6 cm²
  • Autoclavable
  • 121 - 123 ºC (250-253 ºF) at 1.0 bar (100 kPa, 15 psi) for 15 - 20 minutes
  • Sterilization
  • UVSterilizable
  • Filter Size
  • Accepts 47 mm
  • Diameter (Imperial in)
  • 3 in
  • Diameter (Metric cm)
  • 7.6 cm
  • Funnel Capacity (Metric mL)
  • 150 mL
  • Height (Imperial in)
  • 0 in
  • Height (Metric cm)
  • 0 cm
  • Seals
  • 9.6 cm²
CYT40017988 Sentino™ Magnetic filter funnel, 500 mL, 47 mm (1/pkg) 393 
Add to Cart
  • Effective Filtration Area
  • 9.6 cm²
  • Autoclavable
  • 121 - 123 ºC (250-253 ºF) at 1.0 bar (100 kPa, 15 psi) for 15 - 20 minutes
  • Sterilization
  • UVSterilizable
  • Filter Size
  • Accepts 47 mm
  • Diameter (Imperial in)
  • 3 in
  • Diameter (Metric cm)
  • 7.6 cm
  • Funnel Capacity (Metric mL)
  • 150 mL
  • Height (Imperial in)
  • 0 in
  • Height (Metric cm)
  • 0 cm
  • Seals
  • 9.6 cm²
CYT39000001 Sterile ReadyToProcess Hollow Fiber Cartridge, 0.2 1311 
Add to Cart
  • Autoclavable
  • No
  • Application
  • Aseptic clarification and purification of vaccines,monoclonal antibodies, recombinant proteins, and plasmids.\nAseptic cell processing.\nEnvironments where terminal sterilization is not feasible.\nPreclinical through Phase II clinical trials.\nFast-track drug development processes.
  • Pore Size
  • 0.1 µm
  • Material Compliance
  • Biological Reactivity Test, In Vivo per USP 88 Class VI\nL929 MEM Elution Test – ISO 10993-5 (Cytotoxicity)\nHemolysis – Rabbit Blood (direct contact) – ISO 10993-4\nManufactured with materials that comply with EMEA/410/01
CYT39000002 Sterile ReadyToProcess Hollow Fiber Cartridge, 0.45 1311 
Add to Cart
  • Autoclavable
  • No
  • Application
  • Aseptic clarification and purification of vaccines,monoclonal antibodies, recombinant proteins, and plasmids.\nAseptic cell processing.\nEnvironments where terminal sterilization is not feasible.\nPreclinical through Phase II clinical trials.\nFast-track drug development processes.
  • Pore Size
  • 0.1 µm
  • Material Compliance
  • Biological Reactivity Test, In Vivo per USP 88 Class VI\nL929 MEM Elution Test – ISO 10993-5 (Cytotoxicity)\nHemolysis – Rabbit Blood (direct contact) – ISO 10993-4\nManufactured with materials that comply with EMEA/410/01
CYT39000003 Sterile ReadyToProcess Hollow Fiber Cartridge, 0.65 1311 
Add to Cart
  • Autoclavable
  • No
  • Application
  • Aseptic clarification and purification of vaccines,monoclonal antibodies, recombinant proteins, and plasmids.\nAseptic cell processing.\nEnvironments where terminal sterilization is not feasible.\nPreclinical through Phase II clinical trials.\nFast-track drug development processes.
  • Pore Size
  • 0.1 µm
  • Material Compliance
  • Biological Reactivity Test, In Vivo per USP 88 Class VI\nL929 MEM Elution Test – ISO 10993-5 (Cytotoxicity)\nHemolysis – Rabbit Blood (direct contact) – ISO 10993-4\nManufactured with materials that comply with EMEA/410/01
CYT39000000 Sterile ReadyToProcess Hollow Fiber Cartridge, 0.1 1317 
Add to Cart
  • Autoclavable
  • No
  • Application
  • Aseptic clarification and purification of vaccines,monoclonal antibodies, recombinant proteins, and plasmids.\nAseptic cell processing.\nEnvironments where terminal sterilization is not feasible.\nPreclinical through Phase II clinical trials.\nFast-track drug development processes.
  • Pore Size
  • 0.1 µm
  • Material Compliance
  • Biological Reactivity Test, In Vivo per USP 88 Class VI\nL929 MEM Elution Test – ISO 10993-5 (Cytotoxicity)\nHemolysis – Rabbit Blood (direct contact) – ISO 10993-4\nManufactured with materials that comply with EMEA/410/01
CYT39000011 Sterile ReadyToProcess Hollow Fiber Cartridge, 0.1 1717.5 
Add to Cart
  • Autoclavable
  • No
  • Application
  • Aseptic clarification and purification of vaccines,monoclonal antibodies, recombinant proteins, and plasmids.\nAseptic cell processing.\nEnvironments where terminal sterilization is not feasible.\nPreclinical through Phase II clinical trials.\nFast-track drug development processes.
  • Pore Size
  • 0.1 µm
  • Material Compliance
  • Biological Reactivity Test, In Vivo per USP 88 Class VI\nL929 MEM Elution Test – ISO 10993-5 (Cytotoxicity)\nHemolysis – Rabbit Blood (direct contact) – ISO 10993-4\nManufactured with materials that comply with EMEA/410/01

Overview

Capsule filters


Cellulose filter papers

Cellulose filter papers used for general filtration and exhibiting particle retention levels down to 2.5 µm.


Centrifugal devices


Filter Plates

Cytiva filter plates offer a selection of membranes, sample well volumes, and tip configurations allowing researchers to select the right plate for their high throughput application while complying with ANSI/SLAS standards for use in robotic systems.


Glass and quartz microfiber filter

Glass and quartz microfiber filter papers for your filtration workflow.


Immunodiagnostics

Pads and membranes for lateral flow, flow through, blotting, and dipstick assays.


Syringeless filters


Syringe filters - non-sterile


Syringe filters - sterile


Tangential flow filtration for labscale


Thimbles

Cellulose, glass, and quartz thimbles for your filtration workflow.





Resources