+852-3069 6950
css@gugent.com.hk
 

We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.

Catalog No. Product Net Price
CVBY51PK1 Vitipore® II Cartridge Filter 10 in. 0.65 µm Code 5 205 
Add to Cart
  • Bacterial Retention
  • Quantitative retention of 107 CFU/cm2 Saccharomices cerevisiae
  • Cartridge Code
  • Code 5 (2-222) O-rings and spear
  • Cartridge Nominal Length
  • 10 in. (25 cm)
  • Catalogue Number
  • CVBY51PK1
  • Chemistry
  • Polyvinylidene Fluoride (PVDF) Hydrophilic
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 6.9 cm (2.7 in.)
  • Filtration Area
  • 0.78 m²
  • Key Applications
  • Food and BeverageBeerBottled WaterWine
  • Length
  • 10 in. (25 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • Forward: 5.5 bar (80 psid) @ 25 °C; 1.7 bar (25 psid) @ 80 °C; 0.35 bar (5 psid) @ 109 °C. Reverse: 1.7 bar (25 psid) @ 25 °C, intermittent
  • Maximum Inlet Pressure, bar (psi)
  • Forward - 5.5 bar (80 psi) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; 0.35 bar (5 psi) @ 109 °C. Reverse - 1.7 bar (25 psi) @ 25 °C, Intermittent
  • Media
  • Durapore®
  • Pore Size
  • 0.65 µm
  • Seal Material
  • Silicone (SI)
  • Sterility
  • Other
  • Sterilization
  • 100 SIP cycles of 30 min @ 109 °C; hot water sanitized 50 times for 30 min @ 80 °C maximum
  • Support Material
  • Polypropylene
  • Trade Name
  • Vitipore®
  • Wettability
  • Hydrophilic
CVBY51PK1 Vitipore® II Cartridge Filter 10 in. 0.65 µm Code 5 205 
Add to Cart
  • Bacterial Retention
  • Quantitative retention of 107 CFU/cm2 Saccharomices cerevisiae
  • Cartridge Code
  • Code 5 (2-222) O-rings and spear
  • Cartridge Nominal Length
  • 10 in. (25 cm)
  • Catalogue Number
  • CVBY51PK1
  • Chemistry
  • Polyvinylidene Fluoride (PVDF) Hydrophilic
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 6.9 cm (2.7 in.)
  • Filtration Area
  • 0.78 m²
  • Key Applications
  • Food and BeverageBeerBottled WaterWine
  • Length
  • 10 in. (25 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • Forward: 5.5 bar (80 psid) @ 25 °C; 1.7 bar (25 psid) @ 80 °C; 0.35 bar (5 psid) @ 109 °C. Reverse: 1.7 bar (25 psid) @ 25 °C, intermittent
  • Maximum Inlet Pressure, bar (psi)
  • Forward - 5.5 bar (80 psi) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; 0.35 bar (5 psi) @ 109 °C. Reverse - 1.7 bar (25 psi) @ 25 °C, Intermittent
  • Media
  • Durapore®
  • Pore Size
  • 0.65 µm
  • Seal Material
  • Silicone (SI)
  • Sterility
  • Other
  • Sterilization
  • 100 SIP cycles of 30 min @ 109 °C; hot water sanitized 50 times for 30 min @ 80 °C maximum
  • Support Material
  • Polypropylene
  • Trade Name
  • Vitipore®
  • Wettability
  • Hydrophilic
MP0DSSELB0 Manifold Elbow, 90°, 1.5 in. 316 stainless steel 205 
Add to Cart
  • Catalogue Number
  • MP0DSSELB0
  • Material Size
  • 1 each
MP0DSSELB0 Manifold Elbow, 90°, 1.5 in. 316 stainless steel 205 
Add to Cart
  • Catalogue Number
  • MP0DSSELB0
  • Material Size
  • 1 each
D01003S01 Clarigard Cartridge Filter 30 in. 1.0 µm Code 0 Silicone 206 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 0 (2-222) O-rings
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • D01003S01
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Gravimetric Extractables
  • ≤30 mg after 24-h soak in water
  • Length
  • 30 in. (75 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 1.0 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥9 L
  • Pore Size
  • 1.0 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Clarigard®
  • Wettability
  • Hydrophilic
D01003S01 Clarigard Cartridge Filter 30 in. 1.0 µm Code 0 Silicone 206 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 0 (2-222) O-rings
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • D01003S01
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Gravimetric Extractables
  • ≤30 mg after 24-h soak in water
  • Length
  • 30 in. (75 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 1.0 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥9 L
  • Pore Size
  • 1.0 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Clarigard®
  • Wettability
  • Hydrophilic
D01073S01 Clarigard Cartridge Filter 30 in. 1.0 µm Code 7 Silicone 206 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 7 (2-226) O-rings w/locking-tabs
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • D01073S01
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Gravimetric Extractables
  • ≤30 mg after 24-h soak in water
  • Length
  • 30 in. (75 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 1.0 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥9 L
  • Pore Size
  • 1.0 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Clarigard®
  • Wettability
  • Hydrophilic
D01073S01 Clarigard Cartridge Filter 30 in. 1.0 µm Code 7 Silicone 206 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 7 (2-226) O-rings w/locking-tabs
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • D01073S01
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Gravimetric Extractables
  • ≤30 mg after 24-h soak in water
  • Length
  • 30 in. (75 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 1.0 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥9 L
  • Pore Size
  • 1.0 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Clarigard®
  • Wettability
  • Hydrophilic
D01073V01 Clarigard Cartridge Filter 30 in. 1.0 µm Code 7 Fluoroelastomer 206 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 7 (2-226) O-rings w/locking-tabs
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • D01073V01
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Gravimetric Extractables
  • ≤30 mg after 24-h soak in water
  • Length
  • 30 in. (75 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 1.0 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥9 L
  • Pore Size
  • 1.0 µm
  • Seal Material
  • Fluorocarbon rubber
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Clarigard®
  • Wettability
  • Hydrophilic
D03053S01 Clarigard Cartridge Filter 30 in. 3.0 µm Code 5 Silicone 206 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 5 (2-222) O-rings and spear
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • D03053S01
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Gravimetric Extractables
  • ≤30 mg after 24-h soak in water
  • Length
  • 30 in. (75 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 3.0 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥9 L
  • Pore Size
  • 3.0 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Clarigard®
  • Wettability
  • Hydrophilic

Overview

Analytical Sample Preparation Membrane Filtration Devices


Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.


Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.


Filter Membranes

Millex® Syringe Filters

Filtration Holders & Accessories



Resources