+852-3069 6950
css@gugent.com.hk
 

We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.

Catalog No. Product Net Price
CP2072SB1 Bevigard™-L Cartridge Filter 20 in. 2.0 µm Code 7 Special offer 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤1.0 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 7 (2-226) O-ring and spear
  • Cartridge Nominal Length
  • 20 in. (50 cm)
  • Catalogue Number
  • CP2072SB1
  • Chemistry
  • Borosilicate Glass Fiber (BGF)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Device Size
  • 20 in.
  • Diameter
  • 7.4 cm (2.9 in.)
  • Filter Grade
  • AP20
  • Filtration Area
  • 0.92 m²
  • Format
  • Single Layer
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 220 mg per 10-inch cartridge after 24 hours in water at controlled room temperature.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182. All component materials meet the requirements of the EU framework regulation [1935/2004/EC] regarding materials and articles intended to contact food.
  • Key Applications
  • Food and BeverageBeerBottled WaterWine
  • Length
  • 20 in. (50 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 3.5 bar (50 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 3.5 bar (50 psi) @ 25 °C
  • Media
  • Bevigard™-L
  • Nominal Pore Size
  • 2.0 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥5 L
  • Pore Size
  • 2.0 µm
  • Sanitization
  • 30 min with hot water @ 80 °C
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 10 autoclave cycles or SIP @ 121 °C for 30 min
  • Support Material
  • Polypropylene
  • Trade Name
  • Bevigard™
CP2074SB1 Bevigard™-L Cartridge Filter 40 in. 2.0 µm Code 7 Special offer 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤1.0 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 7 (2-226) O-ring and spear
  • Cartridge Nominal Length
  • 40 in. (100 cm)
  • Catalogue Number
  • CP2074SB1
  • Chemistry
  • Borosilicate Glass Fiber (BGF)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Device Size
  • 40 in.
  • Diameter
  • 7.4 cm (2.9 in.)
  • Filter Grade
  • AP20
  • Filtration Area
  • 1.84 m²
  • Format
  • Single Layer
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 220 mg per 10-inch cartridge after 24 hours in water at controlled room temperature.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182. All component materials meet the requirements of the EU framework regulation [1935/2004/EC] regarding materials and articles intended to contact food.
  • Key Applications
  • Food and BeverageBeerBottled WaterWine
  • Length
  • 40 in. (100 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 3.5 bar (50 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 3.5 bar (50 psi) @ 25 °C
  • Media
  • Bevigard™-L
  • Nominal Pore Size
  • 2.0 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥5 L
  • Pore Size
  • 2.0 µm
  • Sanitization
  • 30 min with hot water @ 80 °C
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 10 autoclave cycles or SIP @ 121 °C for 30 min
  • Support Material
  • Polypropylene
  • Trade Name
  • Bevigard™
CP2074SB1 Bevigard™-L Cartridge Filter 40 in. 2.0 µm Code 7 Special offer 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤1.0 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 7 (2-226) O-ring and spear
  • Cartridge Nominal Length
  • 40 in. (100 cm)
  • Catalogue Number
  • CP2074SB1
  • Chemistry
  • Borosilicate Glass Fiber (BGF)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Device Size
  • 40 in.
  • Diameter
  • 7.4 cm (2.9 in.)
  • Filter Grade
  • AP20
  • Filtration Area
  • 1.84 m²
  • Format
  • Single Layer
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 220 mg per 10-inch cartridge after 24 hours in water at controlled room temperature.
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182. All component materials meet the requirements of the EU framework regulation [1935/2004/EC] regarding materials and articles intended to contact food.
  • Key Applications
  • Food and BeverageBeerBottled WaterWine
  • Length
  • 40 in. (100 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 3.5 bar (50 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 3.5 bar (50 psi) @ 25 °C
  • Media
  • Bevigard™-L
  • Nominal Pore Size
  • 2.0 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥5 L
  • Pore Size
  • 2.0 µm
  • Sanitization
  • 30 min with hot water @ 80 °C
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 10 autoclave cycles or SIP @ 121 °C for 30 min
  • Support Material
  • Polypropylene
  • Trade Name
  • Bevigard™
CR2573T06 Polygard-CR Cartridge Filter 30 in. 25 µm Code 7 PTFE-encapsulated Fluoroelastomer Special offer 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 7 (2-226) O-rings w/locking-tabs
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • CR2573T06
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Gravimetric Extractables
  • ≤50 mg after 24-h soak in water
  • Length
  • 30 in. (75 cm)
  • Material Size
  • 6
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 25.0 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥15 L
  • Pore Size
  • 25.0 µm
  • Sanitization
  • 30 min with hot water @ 80 °C
  • Seal Material
  • Polytetrafluoroethylene (PTFE)
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Polygard®
  • Wettability
  • Hydrophilic
CRL603S01 Polygard®-CRL6 0.6 µm Code0 Cartridge Filter, 30in Special offer 
Add to Cart
  • Cartridge Code
  • Code 0 (2-222) O-rings
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • CRL603S01
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Length
  • 30 in. (75 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 0.6 µm
  • Pore Size
  • 0.6 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Polygard®
  • Wettability
  • Hydrophilic
CRL673S01 Polygard®-CRL6 0.6 µm Code7 Cartridge Filter, 30in Special offer 
Add to Cart
  • Cartridge Code
  • Code 7 (2-226) O-rings w/locking-tabs
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • CRL673S01
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Filtration Area
  • 0.69 m²
  • Length
  • 30 in. (75 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 0.6 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥1 L
  • Pore Size
  • 0.65 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Support Material
  • Polypropylene
  • Trade Name
  • Polygard®
  • Wettability
  • Hydrophilic
CRL873S01 Polygard®-CRL8 1.0 µm Code7 Cartridge Filter, 30in Special offer 
Add to Cart
  • Cartridge Code
  • Code 7 (2-226) O-rings w/locking-tabs
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • CRL873S01
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Length
  • 30 in. (75 cm)
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 1.0 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥1 L
  • Pore Size
  • 0.65 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Support Material
  • Polypropylene
  • Trade Name
  • Polygard®
  • Wettability
  • Hydrophilic
CRW1730C6 CRW Filter 30 in. 1.0 µm Code 7 Special offer 
Add to Cart
  • Availability by Geography
  • Available for sale in Japan only
  • Cartridge Code
  • Code 7 (2-226) O-rings w/locking-tabs
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • CRW1730C6
  • Chemistry
  • Polypropylene (PP)Cotton Winding
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Filtration Area
  • 0.15 m²
  • Length
  • 30 in. (75 cm)
  • Material Size
  • 6
  • Maximum Differential Pressure, bar (psid)
  • 490 bar @ 20 °C
  • Maximum Inlet Pressure, bar (psi)
  • 490 bar @ 20 °C
  • Nominal Pore Size
  • 1.0 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥4 L
  • Pore Size
  • 0.45 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • Hot water sanitized @ 80 °C for 30 min
  • Support Material
  • Polypropylene
  • Wettability
  • Hydrophilic
CRW2730B6 CRW Filter 30 in. 2.0 µm Code 7 Special offer 
Add to Cart
  • Availability by Geography
  • Available for sale in Japan only
  • Cartridge Code
  • Code 7 (2-226) O-rings w/locking-tabs
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • CRW2730B6
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Filtration Area
  • 0.15 m²
  • Length
  • 30 in. (75 cm)
  • Material Size
  • 6
  • Maximum Differential Pressure, bar (psid)
  • 490 bar @ 20 °C
  • Maximum Inlet Pressure, bar (psi)
  • 490 bar @ 20 °C
  • Nominal Pore Size
  • 2.0 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥4 L
  • Pore Size
  • 0.45 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • Hot water sanitized @ 80 °C for 30 min
  • Support Material
  • Polypropylene
  • Wettability
  • Hydrophilic
CRW3730B6 CRW Filter 30 in. 3.0 µm Code 7 Special offer 
Add to Cart
  • Availability by Geography
  • Available for sale in Japan only
  • Cartridge Code
  • Code 7 (2-226) O-rings w/locking-tabs
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • CRW3730B6
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Filtration Area
  • 0.15 m²
  • Length
  • 30 in. (75 cm)
  • Material Size
  • 6
  • Maximum Differential Pressure, bar (psid)
  • 490 bar @ 20 °C
  • Maximum Inlet Pressure, bar (psi)
  • 490 bar @ 20 °C
  • Nominal Pore Size
  • 3.0 µm
  • Pore Size
  • 0.45 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • Hot water sanitized @ 80 °C for 30 min
  • Support Material
  • Polypropylene
  • Wettability
  • Hydrophilic

Overview

Analytical Sample Preparation Membrane Filtration Devices


Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.


Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.


Filter Membranes

Millex® Syringe Filters

Filtration Holders & Accessories



Resources