+852-3069 6950
css@gugent.com.hk
 

We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.

Catalog No. Product Net Price
KHVES05HH1 Opticap® Sterile XL 5 Millipore Express® SHR with prefilter 0.5/0.1 µm 9/16 in. HB/HB 403 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Bacterial Retention
  • Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
  • Cartridge Nominal Length
  • 5 in. (12.5 cm)
  • Catalogue Number
  • KHVES05HH1
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Capsule
  • Device Material
  • Gamma stable polypropylene/Polysulfone
  • Device Size
  • 5 in.
  • Diameter
  • 14.5 cm (5.7 in.)
  • European Pressure Equipment Directive
  • EMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
  • Filtration Area
  • 0.24 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Housing Material
  • Polypropylene (PP)
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Hose Barb
  • Inlet Connection Diameter
  • 9/16 in.
  • Inlet to Outlet Width
  • 21.6 cm (8.5 in.)
  • Length
  • 5 in. (12.5 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 1
  • Maximum Differential Pressure
  • 80 psi (5.5 bar) continuous100 psi (6.9 bar) intermittent
  • Maximum Differential Pressure, bar (psid)
  • Forward: 6.9 bar (100 psid) intermittent @ 25 °C; 5.5 bar (80 psid) @ 25 °C; 1.0 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C, intermittent
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 6.9 bar (100 psi) intermittent @ 25 °C; 5.5 bar (80 psi) @ 25 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Millipore Express® SHR w/Prefilter
  • Non-Fiber Releasing
  • This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Hose Barb
  • Outlet Connection Diameter
  • 9/16 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥2 L
  • Pore Size
  • 0.5 / 0.1 µm
  • Seal Material
  • Silicone (SI)
  • Sterility
  • Sterile
  • Sterilization
  • 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
  • Support Material
  • Polyester
  • Trade Name
  • Millipore Express®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Gamma stable polypropylene (PP)
  • Wettability
  • Hydrophilic
  • Width
  • 21.6 cm (8.5 in.)
KHVES05HH1 Opticap® Sterile XL 5 Millipore Express® SHR with prefilter 0.5/0.1 µm 9/16 in. HB/HB 403 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Bacterial Retention
  • Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
  • Cartridge Nominal Length
  • 5 in. (12.5 cm)
  • Catalogue Number
  • KHVES05HH1
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Capsule
  • Device Material
  • Gamma stable polypropylene/Polysulfone
  • Device Size
  • 5 in.
  • Diameter
  • 14.5 cm (5.7 in.)
  • European Pressure Equipment Directive
  • EMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
  • Filtration Area
  • 0.24 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Housing Material
  • Polypropylene (PP)
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Hose Barb
  • Inlet Connection Diameter
  • 9/16 in.
  • Inlet to Outlet Width
  • 21.6 cm (8.5 in.)
  • Length
  • 5 in. (12.5 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 1
  • Maximum Differential Pressure
  • 80 psi (5.5 bar) continuous100 psi (6.9 bar) intermittent
  • Maximum Differential Pressure, bar (psid)
  • Forward: 6.9 bar (100 psid) intermittent @ 25 °C; 5.5 bar (80 psid) @ 25 °C; 1.0 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C, intermittent
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 6.9 bar (100 psi) intermittent @ 25 °C; 5.5 bar (80 psi) @ 25 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Millipore Express® SHR w/Prefilter
  • Non-Fiber Releasing
  • This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Hose Barb
  • Outlet Connection Diameter
  • 9/16 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥2 L
  • Pore Size
  • 0.5 / 0.1 µm
  • Seal Material
  • Silicone (SI)
  • Sterility
  • Sterile
  • Sterilization
  • 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
  • Support Material
  • Polyester
  • Trade Name
  • Millipore Express®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Gamma stable polypropylene (PP)
  • Wettability
  • Hydrophilic
  • Width
  • 21.6 cm (8.5 in.)
KHVES05TB1 Opticap® Sterile XL 5 Millipore Express® SHR with prefilter 0.5/0.1 µm 1-1/2 in. TC-1 in. HB 403 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Bacterial Retention
  • Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
  • Cartridge Nominal Length
  • 5 in. (12.5 cm)
  • Catalogue Number
  • KHVES05TB1
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Capsule
  • Device Material
  • Gamma stable polypropylene/Polysulfone
  • Device Size
  • 5 in.
  • Diameter
  • 14.5 cm (5.7 in.)
  • European Pressure Equipment Directive
  • EMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
  • Filtration Area
  • 0.24 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Housing Material
  • Polypropylene (PP)
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Sanitary Flange
  • Inlet Connection Diameter
  • 1-1/2 in.
  • Inlet to Outlet Width
  • 21.6 cm (8.5 in.)
  • Length
  • 5 in. (12.5 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 1
  • Maximum Differential Pressure
  • 80 psi (5.5 bar) continuous100 psi (6.9 bar) intermittent
  • Maximum Differential Pressure, bar (psid)
  • Forward: 6.9 bar (100 psid) intermittent @ 25 °C; 5.5 bar (80 psid) @ 25 °C; 1.0 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C, intermittent
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 6.9 bar (100 psi) intermittent @ 25 °C; 5.5 bar (80 psi) @ 25 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Millipore Express® SHR w/Prefilter
  • Non-Fiber Releasing
  • This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Hose Barb
  • Outlet Connection Diameter
  • 1 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥2 L
  • Pore Size
  • 0.5 / 0.1 µm
  • Seal Material
  • Silicone (SI)
  • Sterility
  • Sterile
  • Sterilization
  • 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
  • Support Material
  • Polyester
  • Trade Name
  • Millipore Express®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Gamma stable polypropylene (PP)
  • Wettability
  • Hydrophilic
  • Width
  • 21.6 cm (8.5 in.)
KHVES05TB1 Opticap® Sterile XL 5 Millipore Express® SHR with prefilter 0.5/0.1 µm 1-1/2 in. TC-1 in. HB 403 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Bacterial Retention
  • Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
  • Cartridge Nominal Length
  • 5 in. (12.5 cm)
  • Catalogue Number
  • KHVES05TB1
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Capsule
  • Device Material
  • Gamma stable polypropylene/Polysulfone
  • Device Size
  • 5 in.
  • Diameter
  • 14.5 cm (5.7 in.)
  • European Pressure Equipment Directive
  • EMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
  • Filtration Area
  • 0.24 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Housing Material
  • Polypropylene (PP)
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Sanitary Flange
  • Inlet Connection Diameter
  • 1-1/2 in.
  • Inlet to Outlet Width
  • 21.6 cm (8.5 in.)
  • Length
  • 5 in. (12.5 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 1
  • Maximum Differential Pressure
  • 80 psi (5.5 bar) continuous100 psi (6.9 bar) intermittent
  • Maximum Differential Pressure, bar (psid)
  • Forward: 6.9 bar (100 psid) intermittent @ 25 °C; 5.5 bar (80 psid) @ 25 °C; 1.0 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C, intermittent
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 6.9 bar (100 psi) intermittent @ 25 °C; 5.5 bar (80 psi) @ 25 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Millipore Express® SHR w/Prefilter
  • Non-Fiber Releasing
  • This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Hose Barb
  • Outlet Connection Diameter
  • 1 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥2 L
  • Pore Size
  • 0.5 / 0.1 µm
  • Seal Material
  • Silicone (SI)
  • Sterility
  • Sterile
  • Sterilization
  • 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
  • Support Material
  • Polyester
  • Trade Name
  • Millipore Express®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Gamma stable polypropylene (PP)
  • Wettability
  • Hydrophilic
  • Width
  • 21.6 cm (8.5 in.)
KHVES05TH1 Opticap® Sterile XL 5 Millipore Express® SHR with prefilter 0.5/0.1 µm 1-1/2 in. TC-9/16 in. HB 403 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Bacterial Retention
  • Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
  • Cartridge Nominal Length
  • 5 in. (12.5 cm)
  • Catalogue Number
  • KHVES05TH1
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Capsule
  • Device Material
  • Gamma stable polypropylene/Polysulfone
  • Device Size
  • 5 in.
  • Diameter
  • 14.5 cm (5.7 in.)
  • European Pressure Equipment Directive
  • EMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
  • Filtration Area
  • 0.24 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Housing Material
  • Polypropylene (PP)
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Sanitary Flange
  • Inlet Connection Diameter
  • 1-1/2 in.
  • Inlet to Outlet Width
  • 21.6 cm (8.5 in.)
  • Length
  • 5 in. (12.5 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 1
  • Maximum Differential Pressure
  • 80 psi (5.5 bar) continuous100 psi (6.9 bar) intermittent
  • Maximum Differential Pressure, bar (psid)
  • Forward: 6.9 bar (100 psid) intermittent @ 25 °C; 5.5 bar (80 psid) @ 25 °C; 1.0 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C, intermittent
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 6.9 bar (100 psi) intermittent @ 25 °C; 5.5 bar (80 psi) @ 25 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Millipore Express® SHR w/Prefilter
  • Non-Fiber Releasing
  • This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Hose Barb
  • Outlet Connection Diameter
  • 9/16 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥2 L
  • Pore Size
  • 0.5 / 0.1 µm
  • Seal Material
  • Silicone (SI)
  • Sterility
  • Sterile
  • Sterilization
  • 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
  • Support Material
  • Polyester
  • Trade Name
  • Millipore Express®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Gamma stable polypropylene (PP)
  • Wettability
  • Hydrophilic
  • Width
  • 21.6 cm (8.5 in.)
KHVES05TH1 Opticap® Sterile XL 5 Millipore Express® SHR with prefilter 0.5/0.1 µm 1-1/2 in. TC-9/16 in. HB 403 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Bacterial Retention
  • Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
  • Cartridge Nominal Length
  • 5 in. (12.5 cm)
  • Catalogue Number
  • KHVES05TH1
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Capsule
  • Device Material
  • Gamma stable polypropylene/Polysulfone
  • Device Size
  • 5 in.
  • Diameter
  • 14.5 cm (5.7 in.)
  • European Pressure Equipment Directive
  • EMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
  • Filtration Area
  • 0.24 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Housing Material
  • Polypropylene (PP)
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Sanitary Flange
  • Inlet Connection Diameter
  • 1-1/2 in.
  • Inlet to Outlet Width
  • 21.6 cm (8.5 in.)
  • Length
  • 5 in. (12.5 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 1
  • Maximum Differential Pressure
  • 80 psi (5.5 bar) continuous100 psi (6.9 bar) intermittent
  • Maximum Differential Pressure, bar (psid)
  • Forward: 6.9 bar (100 psid) intermittent @ 25 °C; 5.5 bar (80 psid) @ 25 °C; 1.0 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C, intermittent
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 6.9 bar (100 psi) intermittent @ 25 °C; 5.5 bar (80 psi) @ 25 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Millipore Express® SHR w/Prefilter
  • Non-Fiber Releasing
  • This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Hose Barb
  • Outlet Connection Diameter
  • 9/16 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥2 L
  • Pore Size
  • 0.5 / 0.1 µm
  • Seal Material
  • Silicone (SI)
  • Sterility
  • Sterile
  • Sterilization
  • 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
  • Support Material
  • Polyester
  • Trade Name
  • Millipore Express®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Gamma stable polypropylene (PP)
  • Wettability
  • Hydrophilic
  • Width
  • 21.6 cm (8.5 in.)
KHVES05TT1 Opticap® Sterile XL 5 Millipore Express® SHR with prefilter 0.5/0.1 µm 1-1/2 in. TC/TC 403 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Bacterial Retention
  • Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
  • Cartridge Nominal Length
  • 5 in. (12.5 cm)
  • Catalogue Number
  • KHVES05TT1
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Capsule
  • Device Material
  • Gamma stable polypropylene/Polysulfone
  • Device Size
  • 5 in.
  • Diameter
  • 14.5 cm (5.7 in.)
  • European Pressure Equipment Directive
  • EMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
  • Filtration Area
  • 0.24 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Housing Material
  • Polypropylene (PP)
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Sanitary Flange
  • Inlet Connection Diameter
  • 1-1/2 in.
  • Inlet to Outlet Width
  • 21.6 cm (8.5 in.)
  • Length
  • 5 in. (12.5 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 1
  • Maximum Differential Pressure
  • 80 psi (5.5 bar) continuous100 psi (6.9 bar) intermittent
  • Maximum Differential Pressure, bar (psid)
  • Forward: 6.9 bar (100 psid) intermittent @ 25 °C; 5.5 bar (80 psid) @ 25 °C; 1.0 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C, intermittent
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 6.9 bar (100 psi) intermittent @ 25 °C; 5.5 bar (80 psi) @ 25 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Millipore Express® SHR w/Prefilter
  • Non-Fiber Releasing
  • This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Sanitary Flange
  • Outlet Connection Diameter
  • 1-1/2 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥2 L
  • Pore Size
  • 0.5 / 0.1 µm
  • Seal Material
  • Silicone (SI)
  • Sterility
  • Sterile
  • Sterilization
  • 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
  • Support Material
  • Polyester
  • Trade Name
  • Millipore Express®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Gamma stable polypropylene (PP)
  • Wettability
  • Hydrophilic
  • Width
  • 21.6 cm (8.5 in.)
KHVES05TT1 Opticap® Sterile XL 5 Millipore Express® SHR with prefilter 0.5/0.1 µm 1-1/2 in. TC/TC 403 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Bacterial Retention
  • Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
  • Cartridge Nominal Length
  • 5 in. (12.5 cm)
  • Catalogue Number
  • KHVES05TT1
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Capsule
  • Device Material
  • Gamma stable polypropylene/Polysulfone
  • Device Size
  • 5 in.
  • Diameter
  • 14.5 cm (5.7 in.)
  • European Pressure Equipment Directive
  • EMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
  • Filtration Area
  • 0.24 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Housing Material
  • Polypropylene (PP)
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Sanitary Flange
  • Inlet Connection Diameter
  • 1-1/2 in.
  • Inlet to Outlet Width
  • 21.6 cm (8.5 in.)
  • Length
  • 5 in. (12.5 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 1
  • Maximum Differential Pressure
  • 80 psi (5.5 bar) continuous100 psi (6.9 bar) intermittent
  • Maximum Differential Pressure, bar (psid)
  • Forward: 6.9 bar (100 psid) intermittent @ 25 °C; 5.5 bar (80 psid) @ 25 °C; 1.0 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C, intermittent
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 6.9 bar (100 psi) intermittent @ 25 °C; 5.5 bar (80 psi) @ 25 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Millipore Express® SHR w/Prefilter
  • Non-Fiber Releasing
  • This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Sanitary Flange
  • Outlet Connection Diameter
  • 1-1/2 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥2 L
  • Pore Size
  • 0.5 / 0.1 µm
  • Seal Material
  • Silicone (SI)
  • Sterility
  • Sterile
  • Sterilization
  • 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
  • Support Material
  • Polyester
  • Trade Name
  • Millipore Express®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Gamma stable polypropylene (PP)
  • Wettability
  • Hydrophilic
  • Width
  • 21.6 cm (8.5 in.)
KEGBG003FF3 Gamma Phobic Opticap® XL 300 Express SPG 0.2 sanitary flange 404 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Bacterial Retention
  • Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
  • Catalogue Number
  • KEGBG003FF3
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Capsule
  • Device Material
  • Gamma stable polypropylene/Polysulfone
  • Diameter
  • 5.6 cm (2.2 in.)
  • European Pressure Equipment Directive
  • EMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
  • Filtration Area
  • 0.048 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 3 mg after 24 hours in a 70/30% IPA/water mixture at controlled room temperature.
  • Housing Material
  • Polypropylene (PP)
  • Inlet Connection
  • Sanitary Flange
  • Inlet Connection Diameter
  • 3/4 in.
  • Inlet to Outlet Width
  • 11.9 cm (4.7 in.)
  • Key Applications
  • Small scale single-use applications
  • Length
  • 11.9 cm (4.7 in.)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 3
  • Maximum Differential Pressure
  • 60 psi (4.1 bar) continuous
  • Maximum Differential Pressure, bar (psid)
  • Forward: 4.2 bar (60 psid) @ 25 °C; Reverse: 2.1 bar (30 psid) @ 25 °C, intermittent
  • Maximum Inlet Pressure (psig)
  • 60 psig
  • Maximum Inlet Pressure, bar (psi)
  • 4.1 bar (60 psi) @ 23 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Millipore Express® SPG
  • Non-Fiber Releasing
  • This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Sanitary Flange
  • Outlet Connection Diameter
  • 3/4 in.
  • Pore Size
  • 0.2 µm
  • Seal Material
  • Silicone (SI)
  • Sterility
  • Gamma
  • Sterilization
  • Gamma compatible to 45 kGy; 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
  • Support Material
  • Polyethylene
  • Trade Name
  • Opticap®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Polypropylene (PP)
  • Wettability
  • Hydrophobic
  • Width
  • 11.9 cm (4.7 in.)
KEGBG003HH3 Gamma Phobic Opticap® XL 300 Express SPG 0.2 hose barb 404 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Bacterial Retention
  • Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
  • Catalogue Number
  • KEGBG003HH3
  • Chemistry
  • Polyethersulfone (PES)
  • Device Configuration
  • Capsule
  • Device Material
  • Gamma stable polypropylene/Polysulfone
  • Diameter
  • 5.6 cm (2.2 in.)
  • European Pressure Equipment Directive
  • EMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
  • Filtration Area
  • 0.048 m²
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 3 mg after 24 hours in a 70/30% IPA/water mixture at controlled room temperature.
  • Housing Material
  • Polypropylene (PP)
  • Inlet Connection
  • Hose Barb
  • Inlet Connection Diameter
  • 9/16 in.
  • Inlet to Outlet Width
  • 11.9 cm (4.7 in.)
  • Key Applications
  • Small scale single-use applications
  • Length
  • 11.9 cm (4.7 in.)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 3
  • Maximum Differential Pressure
  • 60 psi (4.1 bar) continuous
  • Maximum Differential Pressure, bar (psid)
  • Forward: 4.2 bar (60 psid) @ 25 °C; Reverse: 2.1 bar (30 psid) @ 25 °C, intermittent
  • Maximum Inlet Pressure (psig)
  • 60 psig
  • Maximum Inlet Pressure, bar (psi)
  • 4.1 bar (60 psi) @ 23 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Millipore Express® SPG
  • Non-Fiber Releasing
  • This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Hose Barb
  • Outlet Connection Diameter
  • 9/16 in.
  • Pore Size
  • 0.2 µm
  • Seal Material
  • Silicone (SI)
  • Sterility
  • Gamma
  • Sterilization
  • Gamma compatible to 45 kGy; 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
  • Support Material
  • Polyethylene
  • Trade Name
  • Opticap®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Polypropylene (PP)
  • Wettability
  • Hydrophobic
  • Width
  • 11.9 cm (4.7 in.)

Overview

Analytical Sample Preparation Membrane Filtration Devices


Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.


Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.


Filter Membranes

Millex® Syringe Filters

Filtration Holders & Accessories



Resources