We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Code
Not Applicable
Catalogue Number
MCHL30S03
Chemistry
Polyvinylidene Fluoride (PVDF)
Device Configuration
Cartridge
Device Material
Polysulfone
Filtration Area
1500 cm²
Flow Rate
75 L/min @ 3.15 bar ΔP
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 7.5 mg per sterilized device after 24 hours in water at controlled room temperature.
Material Package
Double Easy-Open bag
Material Size
3
Maximum Differential Pressure, bar (psid)
Forward: 4.1 bar (60 psid) @ 25 °C; 1.7 bar (25 psid) @ 80 °C; 0.35 bar (5 psid) @ 123 °C; Reverse: 0.7 bar (10 psid) @ 25 °C
Maximum Inlet Pressure, bar (psi)
Forward - 4.1 bar (60 psi) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; 0.35 bar (5 psi) @ 123 °C; Reverse - 0.7 bar (10 psi) @ 25 °C
Media
Durapore®
Non-Fiber Releasing
This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥200 mL
Pore Size
0.45 µm
Seal Material
Silicone (SI)
Sterility
Other
Sterilization
5 SIP cycles of 60 min @ 135 °C; 5 autoclave cycles of 60 min @ 126 °C
Support Material
Polysulfone
Trade Name
Millidisk®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Code
Not Applicable
Catalogue Number
MCHL30S03
Chemistry
Polyvinylidene Fluoride (PVDF)
Device Configuration
Cartridge
Device Material
Polysulfone
Filtration Area
1500 cm²
Flow Rate
75 L/min @ 3.15 bar ΔP
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 7.5 mg per sterilized device after 24 hours in water at controlled room temperature.
Material Package
Double Easy-Open bag
Material Size
3
Maximum Differential Pressure, bar (psid)
Forward: 4.1 bar (60 psid) @ 25 °C; 1.7 bar (25 psid) @ 80 °C; 0.35 bar (5 psid) @ 123 °C; Reverse: 0.7 bar (10 psid) @ 25 °C
Maximum Inlet Pressure, bar (psi)
Forward - 4.1 bar (60 psi) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; 0.35 bar (5 psi) @ 123 °C; Reverse - 0.7 bar (10 psi) @ 25 °C
Media
Durapore®
Non-Fiber Releasing
This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥200 mL
Pore Size
0.45 µm
Seal Material
Silicone (SI)
Sterility
Other
Sterilization
5 SIP cycles of 60 min @ 135 °C; 5 autoclave cycles of 60 min @ 126 °C
Support Material
Polysulfone
Trade Name
Millidisk®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Bacterial Retention
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
Cartridge Nominal Length
4 in. (10 cm)
Catalogue Number
KVVLA04FF3
Chemistry
Polyvinylidene Fluoride (PVDF)
Device Configuration
Capsule
Device Material
Polypropylene
Device Size
4 in.
Diameter
14.5 cm (5.7 in.)
European Pressure Equipment Directive
EMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
Filtration Area
0.19 m²
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 10 mg per capsule after 24 hours in water at controlled room temperature.
Housing Material
Polypropylene (PP)
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
Inlet Connection
Sanitary Flange
Inlet Connection Diameter
3/4 in.
Inlet to Outlet Width
18.8 cm (7.4 in.)
Length
4 in. (10 cm)
Material Package
Double Easy-Open bag
Material Size
3
Maximum Differential Pressure, bar (psid)
Forward: 5.5 bar (80 psid) @ 25 °C; 1.0 bar (15 psid) @ 80 °C. Reverse: 3.5 bar (50 psid) @ 25 °C, intermittent
Maximum Inlet Pressure (psig)
80 psig
Maximum Inlet Pressure, bar (psi)
5.5 bar (80 psi) @ 23 °C; 2.8 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
Maximum Inlet Temperature
25 °C
Media
Durapore®
Non-Fiber Releasing
This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Outlet Connection
Sanitary Flange
Outlet Connection Diameter
3/4 in.
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥500 mL
Pore Size
0.1 µm
Seal Material
Silicone (SI)
Sterility
Other
Sterilization
3 autoclave cycles of 60 min @ 126 °C; not in-line steam sterilizable
Support Material
Polypropylene
Trade Name
Opticap®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Bacterial Retention
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
Cartridge Nominal Length
10 in. (25 cm)
Catalogue Number
KHGLS10FF1
Chemistry
Polyvinylidene Fluoride (PVDF)
Device Configuration
Capsule
Device Material
Polypropylene
Device Size
10 in.
Diameter
10.7 cm (4.2 in.)
European Pressure Equipment Directive
EMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
Filtration Area
0.55 m²
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Housing Material
Polypropylene (PP)
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
Inlet Connection
Sanitary Flange
Inlet Connection Diameter
3/4 in.
Inlet to Outlet Width
33.5 cm (13.2 in.)
Length
10 in. (25 cm)
Material Package
Double Easy-Open bag
Material Size
1
Maximum Differential Pressure, bar (psid)
Forward: 5.5 bar (80 psid) @ 25 °C; 1.05 bar (15 psid) @ 80 °C. Reverse: 3.5 bar (50 psid) @ 25 °C, intermittent
Maximum Inlet Pressure (psig)
80 psig
Maximum Inlet Pressure, bar (psi)
5.5 bar (80 psi) @ 23 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
Maximum Inlet Temperature
25 °C
Media
Multilayer Durapore®
Non-Fiber Releasing
This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Outlet Connection
Sanitary Flange
Outlet Connection Diameter
3/4 in.
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥1.5 L
Pore Size
0.45 / 0.22 µm
Seal Material
Lead O-ring: Silicone-coated EPDM, Outer O-ring: Silicone
Sterility
Sterile
Sterilization
3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
Support Material
Polyester/Polyethylene
Trade Name
Opticap®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.
Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.