+852-3069 6950
css@gugent.com.hk
 

We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.

Catalog No. Product Net Price
KGW1A3TTT1 Opticap® XLT30 Polysep® II 1.0/0.2/0.1 µm 1-1/2 in. TC 511 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • KGW1A3TTT1
  • Chemistry
  • Mixed Cellulose Esters (MCE)
  • Device Configuration
  • Capsule
  • Device Material
  • Polypropylene
  • Device Size
  • 30 in.
  • Diameter
  • 1-1/2 in.
  • Filtration Area
  • 1.26 m²
  • Format
  • Triple Layer
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 435 mg per capsule after a 15 L flush and 24 hours in water at controlled room temperature.
  • Housing Material
  • Polypropylene (PP)
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Sanitary Flange
  • Inlet Connection Diameter
  • 1-1/2 in.
  • Inlet to Outlet Width
  • 15.2 cm (6.0 in.)
  • Length
  • 30 in. (75 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 3.5 bar (50 psid) @ 25 °C
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 23 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Polysep™ II
  • Nominal Pore Size
  • 1.0 / 0.2 / 0.1 µm
  • Non-Fiber Releasing
  • This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Sanitary Flange
  • Outlet Connection Diameter
  • 1-1/2 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥15 L
  • Pore Size
  • 1.0 / 0.2 / 0.1 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 3 autoclave cycles of 30 min @ 121 °C; not in-line steam sterilizable
  • Support Material
  • Polypropylene
  • Trade Name
  • Opticap®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Polypropylene (PP)
  • Width
  • 15.2 cm (6.0 in.)
KGW1A3TTT1 Opticap® XLT30 Polysep® II 1.0/0.2/0.1 µm 1-1/2 in. TC 511 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • KGW1A3TTT1
  • Chemistry
  • Mixed Cellulose Esters (MCE)
  • Device Configuration
  • Capsule
  • Device Material
  • Polypropylene
  • Device Size
  • 30 in.
  • Diameter
  • 1-1/2 in.
  • Filtration Area
  • 1.26 m²
  • Format
  • Triple Layer
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 435 mg per capsule after a 15 L flush and 24 hours in water at controlled room temperature.
  • Housing Material
  • Polypropylene (PP)
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Sanitary Flange
  • Inlet Connection Diameter
  • 1-1/2 in.
  • Inlet to Outlet Width
  • 15.2 cm (6.0 in.)
  • Length
  • 30 in. (75 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 3.5 bar (50 psid) @ 25 °C
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 23 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Polysep™ II
  • Nominal Pore Size
  • 1.0 / 0.2 / 0.1 µm
  • Non-Fiber Releasing
  • This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Sanitary Flange
  • Outlet Connection Diameter
  • 1-1/2 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥15 L
  • Pore Size
  • 1.0 / 0.2 / 0.1 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 3 autoclave cycles of 30 min @ 121 °C; not in-line steam sterilizable
  • Support Material
  • Polypropylene
  • Trade Name
  • Opticap®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Polypropylene (PP)
  • Width
  • 15.2 cm (6.0 in.)
MP0DCR0D05 Clamp Rod for Pilot Holder w/Expansion Kit 511 
Add to Cart
  • Catalogue Number
  • MP0DCR0D05
  • Material Size
  • 1
MP0DCR0D05 Clamp Rod for Pilot Holder w/Expansion Kit 511 
Add to Cart
  • Catalogue Number
  • MP0DCR0D05
  • Material Size
  • 1
KGW2A3TTT1 Opticap® XLT30 Polysep® II 1.0/1.2 µm 1-1/2 in. TC 512 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • KGW2A3TTT1
  • Chemistry
  • Mixed Cellulose Esters (MCE)
  • Device Configuration
  • Capsule
  • Device Material
  • Polypropylene
  • Device Size
  • 30 in.
  • Diameter
  • 1-1/2 in.
  • Filtration Area
  • 1.38 m²
  • Format
  • Double Layer
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 435 mg per capsule after a 15 L flush and 24 hours in water at controlled room temperature.
  • Housing Material
  • Polypropylene (PP)
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Sanitary Flange
  • Inlet Connection Diameter
  • 1-1/2 in.
  • Inlet to Outlet Width
  • 15.2 cm (6.0 in.)
  • Length
  • 30 in. (75 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 3.5 bar (50 psid) @ 25 °C
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 23 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Polysep™ II
  • Nominal Pore Size
  • 1.0 / 1.2 µm
  • Non-Fiber Releasing
  • This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Sanitary Flange
  • Outlet Connection Diameter
  • 1-1/2 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥15 L
  • Pore Size
  • 1.0 / 1.2 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 3 autoclave cycles of 30 min @ 121 °C; not in-line steam sterilizable
  • Support Material
  • Polypropylene
  • Trade Name
  • Opticap®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Polypropylene (PP)
  • Width
  • 15.2 cm (6.0 in.)
KGW2A3TTT1 Opticap® XLT30 Polysep® II 1.0/1.2 µm 1-1/2 in. TC 512 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • KGW2A3TTT1
  • Chemistry
  • Mixed Cellulose Esters (MCE)
  • Device Configuration
  • Capsule
  • Device Material
  • Polypropylene
  • Device Size
  • 30 in.
  • Diameter
  • 1-1/2 in.
  • Filtration Area
  • 1.38 m²
  • Format
  • Double Layer
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 435 mg per capsule after a 15 L flush and 24 hours in water at controlled room temperature.
  • Housing Material
  • Polypropylene (PP)
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Sanitary Flange
  • Inlet Connection Diameter
  • 1-1/2 in.
  • Inlet to Outlet Width
  • 15.2 cm (6.0 in.)
  • Length
  • 30 in. (75 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 3.5 bar (50 psid) @ 25 °C
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 23 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Polysep™ II
  • Nominal Pore Size
  • 1.0 / 1.2 µm
  • Non-Fiber Releasing
  • This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Sanitary Flange
  • Outlet Connection Diameter
  • 1-1/2 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥15 L
  • Pore Size
  • 1.0 / 1.2 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 3 autoclave cycles of 30 min @ 121 °C; not in-line steam sterilizable
  • Support Material
  • Polypropylene
  • Trade Name
  • Opticap®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Polypropylene (PP)
  • Width
  • 15.2 cm (6.0 in.)
KGW3A3THH1 Opticap® XLT30 Polysep® II 1.0/0.2 µm 5/8 in. HB 512 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • KGW3A3THH1
  • Chemistry
  • Mixed Cellulose Esters (MCE)
  • Device Configuration
  • Capsule
  • Device Material
  • Polypropylene
  • Device Size
  • 30 in.
  • Diameter
  • 5/8 in.
  • Filtration Area
  • 1.38 m²
  • Format
  • Double Layer
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 435 mg per capsule after a 15 L flush and 24 hours in water at controlled room temperature.
  • Housing Material
  • Polypropylene (PP)
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Hose Barb
  • Inlet Connection Diameter
  • 5/8 in.
  • Inlet to Outlet Width
  • 19.8 cm (7.8 in.)
  • Length
  • 30 in. (75 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 3.5 bar (50 psid) @ 25 °C
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 23 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Polysep™ II
  • Nominal Pore Size
  • 1.0 / 0.2 µm
  • Non-Fiber Releasing
  • This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Hose Barb
  • Outlet Connection Diameter
  • 5/8 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥15 L
  • Pore Size
  • 1.0 / 0.2 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 3 autoclave cycles of 30 min @ 121 °C; not in-line steam sterilizable
  • Support Material
  • Polypropylene
  • Trade Name
  • Opticap®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Polypropylene (PP)
  • Width
  • 19.8 cm (7.8 in.)
KGW3A3THH1 Opticap® XLT30 Polysep® II 1.0/0.2 µm 5/8 in. HB 512 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • KGW3A3THH1
  • Chemistry
  • Mixed Cellulose Esters (MCE)
  • Device Configuration
  • Capsule
  • Device Material
  • Polypropylene
  • Device Size
  • 30 in.
  • Diameter
  • 5/8 in.
  • Filtration Area
  • 1.38 m²
  • Format
  • Double Layer
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 435 mg per capsule after a 15 L flush and 24 hours in water at controlled room temperature.
  • Housing Material
  • Polypropylene (PP)
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Hose Barb
  • Inlet Connection Diameter
  • 5/8 in.
  • Inlet to Outlet Width
  • 19.8 cm (7.8 in.)
  • Length
  • 30 in. (75 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 3.5 bar (50 psid) @ 25 °C
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 23 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Polysep™ II
  • Nominal Pore Size
  • 1.0 / 0.2 µm
  • Non-Fiber Releasing
  • This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Hose Barb
  • Outlet Connection Diameter
  • 5/8 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥15 L
  • Pore Size
  • 1.0 / 0.2 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 3 autoclave cycles of 30 min @ 121 °C; not in-line steam sterilizable
  • Support Material
  • Polypropylene
  • Trade Name
  • Opticap®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Polypropylene (PP)
  • Width
  • 19.8 cm (7.8 in.)
KGW3A3TTT1 Opticap® XLT30 Polysep® II 1.0/0.2 µm 1-1/2 in. TC 512 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • KGW3A3TTT1
  • Chemistry
  • Mixed Cellulose Esters (MCE)
  • Device Configuration
  • Capsule
  • Device Material
  • Polypropylene
  • Device Size
  • 30 in.
  • Diameter
  • 1-1/2 in.
  • Filtration Area
  • 1.38 m²
  • Format
  • Double Layer
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 435 mg per capsule after a 15 L flush and 24 hours in water at controlled room temperature.
  • Housing Material
  • Polypropylene (PP)
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Sanitary Flange
  • Inlet Connection Diameter
  • 1-1/2 in.
  • Inlet to Outlet Width
  • 15.2 cm (6.0 in.)
  • Length
  • 30 in. (75 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 3.5 bar (50 psid) @ 25 °C
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 23 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Polysep™ II
  • Nominal Pore Size
  • 1.0 / 0.2 µm
  • Non-Fiber Releasing
  • This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Sanitary Flange
  • Outlet Connection Diameter
  • 1-1/2 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥15 L
  • Pore Size
  • 1.0 / 0.2 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 3 autoclave cycles of 30 min @ 121 °C; not in-line steam sterilizable
  • Support Material
  • Polypropylene
  • Trade Name
  • Opticap®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Polypropylene (PP)
  • Width
  • 15.2 cm (6.0 in.)
KGW3A3TTT1 Opticap® XLT30 Polysep® II 1.0/0.2 µm 1-1/2 in. TC 512 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Nominal Length
  • 30 in. (75 cm)
  • Catalogue Number
  • KGW3A3TTT1
  • Chemistry
  • Mixed Cellulose Esters (MCE)
  • Device Configuration
  • Capsule
  • Device Material
  • Polypropylene
  • Device Size
  • 30 in.
  • Diameter
  • 1-1/2 in.
  • Filtration Area
  • 1.38 m²
  • Format
  • Double Layer
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 435 mg per capsule after a 15 L flush and 24 hours in water at controlled room temperature.
  • Housing Material
  • Polypropylene (PP)
  • Indirect Food Additive
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
  • Sanitary Flange
  • Inlet Connection Diameter
  • 1-1/2 in.
  • Inlet to Outlet Width
  • 15.2 cm (6.0 in.)
  • Length
  • 30 in. (75 cm)
  • Material Package
  • Double Easy-Open bag
  • Material Size
  • 1
  • Maximum Differential Pressure, bar (psid)
  • 3.5 bar (50 psid) @ 25 °C
  • Maximum Inlet Pressure (psig)
  • 80 psig
  • Maximum Inlet Pressure, bar (psi)
  • 5.5 bar (80 psi) @ 23 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
  • Maximum Inlet Temperature
  • 25 °C
  • Media
  • Polysep™ II
  • Nominal Pore Size
  • 1.0 / 0.2 µm
  • Non-Fiber Releasing
  • This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
  • Sanitary Flange
  • Outlet Connection Diameter
  • 1-1/2 in.
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥15 L
  • Pore Size
  • 1.0 / 0.2 µm
  • Seal Material
  • Silicone (SI)
  • Sterilization
  • 3 autoclave cycles of 30 min @ 121 °C; not in-line steam sterilizable
  • Support Material
  • Polypropylene
  • Trade Name
  • Opticap®
  • USP Bacterial Endotoxins
  • A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
  • Vent Cap Material
  • Polypropylene (PP)
  • Width
  • 15.2 cm (6.0 in.)

Overview

Analytical Sample Preparation Membrane Filtration Devices


Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.


Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.


Filter Membranes

Millex® Syringe Filters

Filtration Holders & Accessories



Resources