KGW1A3TTT1
Opticap® XLT30 Polysep® II 1.0/0.2/0.1 µm 1-1/2 in. TC
511
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Nominal Length
30 in. (75 cm)
Catalogue Number
KGW1A3TTT1
Chemistry
Mixed Cellulose Esters (MCE)
Device Configuration
Capsule
Device Material
Polypropylene
Device Size
30 in.
Diameter
1-1/2 in.
Filtration Area
1.26 m²
Format
Triple Layer
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 435 mg per capsule after a 15 L flush and 24 hours in water at controlled room temperature.
Housing Material
Polypropylene (PP)
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
Inlet Connection
Sanitary Flange
Inlet Connection Diameter
1-1/2 in.
Inlet to Outlet Width
15.2 cm (6.0 in.)
Length
30 in. (75 cm)
Material Package
Double Easy-Open bag
Material Size
1
Maximum Differential Pressure, bar (psid)
3.5 bar (50 psid) @ 25 °C
Maximum Inlet Pressure (psig)
80 psig
Maximum Inlet Pressure, bar (psi)
5.5 bar (80 psi) @ 23 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
Maximum Inlet Temperature
25 °C
Media
Polysep™ II
Nominal Pore Size
1.0 / 0.2 / 0.1 µm
Non-Fiber Releasing
This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Outlet Connection
Sanitary Flange
Outlet Connection Diameter
1-1/2 in.
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥15 L
Pore Size
1.0 / 0.2 / 0.1 µm
Seal Material
Silicone (SI)
Sterilization
3 autoclave cycles of 30 min @ 121 °C; not in-line steam sterilizable
Support Material
Polypropylene
Trade Name
Opticap®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Vent Cap Material
Polypropylene (PP)
Width
15.2 cm (6.0 in.)
KGW1A3TTT1
Opticap® XLT30 Polysep® II 1.0/0.2/0.1 µm 1-1/2 in. TC
511
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Nominal Length
30 in. (75 cm)
Catalogue Number
KGW1A3TTT1
Chemistry
Mixed Cellulose Esters (MCE)
Device Configuration
Capsule
Device Material
Polypropylene
Device Size
30 in.
Diameter
1-1/2 in.
Filtration Area
1.26 m²
Format
Triple Layer
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 435 mg per capsule after a 15 L flush and 24 hours in water at controlled room temperature.
Housing Material
Polypropylene (PP)
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
Inlet Connection
Sanitary Flange
Inlet Connection Diameter
1-1/2 in.
Inlet to Outlet Width
15.2 cm (6.0 in.)
Length
30 in. (75 cm)
Material Package
Double Easy-Open bag
Material Size
1
Maximum Differential Pressure, bar (psid)
3.5 bar (50 psid) @ 25 °C
Maximum Inlet Pressure (psig)
80 psig
Maximum Inlet Pressure, bar (psi)
5.5 bar (80 psi) @ 23 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
Maximum Inlet Temperature
25 °C
Media
Polysep™ II
Nominal Pore Size
1.0 / 0.2 / 0.1 µm
Non-Fiber Releasing
This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Outlet Connection
Sanitary Flange
Outlet Connection Diameter
1-1/2 in.
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥15 L
Pore Size
1.0 / 0.2 / 0.1 µm
Seal Material
Silicone (SI)
Sterilization
3 autoclave cycles of 30 min @ 121 °C; not in-line steam sterilizable
Support Material
Polypropylene
Trade Name
Opticap®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Vent Cap Material
Polypropylene (PP)
Width
15.2 cm (6.0 in.)
MP0DCR0D05
Clamp Rod for Pilot Holder w/Expansion Kit
511
Add to Cart
Catalogue Number
MP0DCR0D05
Material Size
1
MP0DCR0D05
Clamp Rod for Pilot Holder w/Expansion Kit
511
Add to Cart
Catalogue Number
MP0DCR0D05
Material Size
1
KGW2A3TTT1
Opticap® XLT30 Polysep® II 1.0/1.2 µm 1-1/2 in. TC
512
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Nominal Length
30 in. (75 cm)
Catalogue Number
KGW2A3TTT1
Chemistry
Mixed Cellulose Esters (MCE)
Device Configuration
Capsule
Device Material
Polypropylene
Device Size
30 in.
Diameter
1-1/2 in.
Filtration Area
1.38 m²
Format
Double Layer
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 435 mg per capsule after a 15 L flush and 24 hours in water at controlled room temperature.
Housing Material
Polypropylene (PP)
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
Inlet Connection
Sanitary Flange
Inlet Connection Diameter
1-1/2 in.
Inlet to Outlet Width
15.2 cm (6.0 in.)
Length
30 in. (75 cm)
Material Package
Double Easy-Open bag
Material Size
1
Maximum Differential Pressure, bar (psid)
3.5 bar (50 psid) @ 25 °C
Maximum Inlet Pressure (psig)
80 psig
Maximum Inlet Pressure, bar (psi)
5.5 bar (80 psi) @ 23 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
Maximum Inlet Temperature
25 °C
Media
Polysep™ II
Nominal Pore Size
1.0 / 1.2 µm
Non-Fiber Releasing
This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Outlet Connection
Sanitary Flange
Outlet Connection Diameter
1-1/2 in.
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥15 L
Pore Size
1.0 / 1.2 µm
Seal Material
Silicone (SI)
Sterilization
3 autoclave cycles of 30 min @ 121 °C; not in-line steam sterilizable
Support Material
Polypropylene
Trade Name
Opticap®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Vent Cap Material
Polypropylene (PP)
Width
15.2 cm (6.0 in.)
KGW2A3TTT1
Opticap® XLT30 Polysep® II 1.0/1.2 µm 1-1/2 in. TC
512
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Nominal Length
30 in. (75 cm)
Catalogue Number
KGW2A3TTT1
Chemistry
Mixed Cellulose Esters (MCE)
Device Configuration
Capsule
Device Material
Polypropylene
Device Size
30 in.
Diameter
1-1/2 in.
Filtration Area
1.38 m²
Format
Double Layer
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 435 mg per capsule after a 15 L flush and 24 hours in water at controlled room temperature.
Housing Material
Polypropylene (PP)
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
Inlet Connection
Sanitary Flange
Inlet Connection Diameter
1-1/2 in.
Inlet to Outlet Width
15.2 cm (6.0 in.)
Length
30 in. (75 cm)
Material Package
Double Easy-Open bag
Material Size
1
Maximum Differential Pressure, bar (psid)
3.5 bar (50 psid) @ 25 °C
Maximum Inlet Pressure (psig)
80 psig
Maximum Inlet Pressure, bar (psi)
5.5 bar (80 psi) @ 23 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
Maximum Inlet Temperature
25 °C
Media
Polysep™ II
Nominal Pore Size
1.0 / 1.2 µm
Non-Fiber Releasing
This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Outlet Connection
Sanitary Flange
Outlet Connection Diameter
1-1/2 in.
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥15 L
Pore Size
1.0 / 1.2 µm
Seal Material
Silicone (SI)
Sterilization
3 autoclave cycles of 30 min @ 121 °C; not in-line steam sterilizable
Support Material
Polypropylene
Trade Name
Opticap®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Vent Cap Material
Polypropylene (PP)
Width
15.2 cm (6.0 in.)
KGW3A3THH1
Opticap® XLT30 Polysep® II 1.0/0.2 µm 5/8 in. HB
512
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Nominal Length
30 in. (75 cm)
Catalogue Number
KGW3A3THH1
Chemistry
Mixed Cellulose Esters (MCE)
Device Configuration
Capsule
Device Material
Polypropylene
Device Size
30 in.
Diameter
5/8 in.
Filtration Area
1.38 m²
Format
Double Layer
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 435 mg per capsule after a 15 L flush and 24 hours in water at controlled room temperature.
Housing Material
Polypropylene (PP)
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
Inlet Connection
Hose Barb
Inlet Connection Diameter
5/8 in.
Inlet to Outlet Width
19.8 cm (7.8 in.)
Length
30 in. (75 cm)
Material Package
Double Easy-Open bag
Material Size
1
Maximum Differential Pressure, bar (psid)
3.5 bar (50 psid) @ 25 °C
Maximum Inlet Pressure (psig)
80 psig
Maximum Inlet Pressure, bar (psi)
5.5 bar (80 psi) @ 23 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
Maximum Inlet Temperature
25 °C
Media
Polysep™ II
Nominal Pore Size
1.0 / 0.2 µm
Non-Fiber Releasing
This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Outlet Connection
Hose Barb
Outlet Connection Diameter
5/8 in.
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥15 L
Pore Size
1.0 / 0.2 µm
Seal Material
Silicone (SI)
Sterilization
3 autoclave cycles of 30 min @ 121 °C; not in-line steam sterilizable
Support Material
Polypropylene
Trade Name
Opticap®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Vent Cap Material
Polypropylene (PP)
Width
19.8 cm (7.8 in.)
KGW3A3THH1
Opticap® XLT30 Polysep® II 1.0/0.2 µm 5/8 in. HB
512
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Nominal Length
30 in. (75 cm)
Catalogue Number
KGW3A3THH1
Chemistry
Mixed Cellulose Esters (MCE)
Device Configuration
Capsule
Device Material
Polypropylene
Device Size
30 in.
Diameter
5/8 in.
Filtration Area
1.38 m²
Format
Double Layer
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 435 mg per capsule after a 15 L flush and 24 hours in water at controlled room temperature.
Housing Material
Polypropylene (PP)
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
Inlet Connection
Hose Barb
Inlet Connection Diameter
5/8 in.
Inlet to Outlet Width
19.8 cm (7.8 in.)
Length
30 in. (75 cm)
Material Package
Double Easy-Open bag
Material Size
1
Maximum Differential Pressure, bar (psid)
3.5 bar (50 psid) @ 25 °C
Maximum Inlet Pressure (psig)
80 psig
Maximum Inlet Pressure, bar (psi)
5.5 bar (80 psi) @ 23 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
Maximum Inlet Temperature
25 °C
Media
Polysep™ II
Nominal Pore Size
1.0 / 0.2 µm
Non-Fiber Releasing
This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Outlet Connection
Hose Barb
Outlet Connection Diameter
5/8 in.
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥15 L
Pore Size
1.0 / 0.2 µm
Seal Material
Silicone (SI)
Sterilization
3 autoclave cycles of 30 min @ 121 °C; not in-line steam sterilizable
Support Material
Polypropylene
Trade Name
Opticap®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Vent Cap Material
Polypropylene (PP)
Width
19.8 cm (7.8 in.)
KGW3A3TTT1
Opticap® XLT30 Polysep® II 1.0/0.2 µm 1-1/2 in. TC
512
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Nominal Length
30 in. (75 cm)
Catalogue Number
KGW3A3TTT1
Chemistry
Mixed Cellulose Esters (MCE)
Device Configuration
Capsule
Device Material
Polypropylene
Device Size
30 in.
Diameter
1-1/2 in.
Filtration Area
1.38 m²
Format
Double Layer
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 435 mg per capsule after a 15 L flush and 24 hours in water at controlled room temperature.
Housing Material
Polypropylene (PP)
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
Inlet Connection
Sanitary Flange
Inlet Connection Diameter
1-1/2 in.
Inlet to Outlet Width
15.2 cm (6.0 in.)
Length
30 in. (75 cm)
Material Package
Double Easy-Open bag
Material Size
1
Maximum Differential Pressure, bar (psid)
3.5 bar (50 psid) @ 25 °C
Maximum Inlet Pressure (psig)
80 psig
Maximum Inlet Pressure, bar (psi)
5.5 bar (80 psi) @ 23 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
Maximum Inlet Temperature
25 °C
Media
Polysep™ II
Nominal Pore Size
1.0 / 0.2 µm
Non-Fiber Releasing
This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Outlet Connection
Sanitary Flange
Outlet Connection Diameter
1-1/2 in.
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥15 L
Pore Size
1.0 / 0.2 µm
Seal Material
Silicone (SI)
Sterilization
3 autoclave cycles of 30 min @ 121 °C; not in-line steam sterilizable
Support Material
Polypropylene
Trade Name
Opticap®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Vent Cap Material
Polypropylene (PP)
Width
15.2 cm (6.0 in.)
KGW3A3TTT1
Opticap® XLT30 Polysep® II 1.0/0.2 µm 1-1/2 in. TC
512
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Nominal Length
30 in. (75 cm)
Catalogue Number
KGW3A3TTT1
Chemistry
Mixed Cellulose Esters (MCE)
Device Configuration
Capsule
Device Material
Polypropylene
Device Size
30 in.
Diameter
1-1/2 in.
Filtration Area
1.38 m²
Format
Double Layer
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 435 mg per capsule after a 15 L flush and 24 hours in water at controlled room temperature.
Housing Material
Polypropylene (PP)
Indirect Food Additive
All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
Inlet Connection
Sanitary Flange
Inlet Connection Diameter
1-1/2 in.
Inlet to Outlet Width
15.2 cm (6.0 in.)
Length
30 in. (75 cm)
Material Package
Double Easy-Open bag
Material Size
1
Maximum Differential Pressure, bar (psid)
3.5 bar (50 psid) @ 25 °C
Maximum Inlet Pressure (psig)
80 psig
Maximum Inlet Pressure, bar (psi)
5.5 bar (80 psi) @ 23 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
Maximum Inlet Temperature
25 °C
Media
Polysep™ II
Nominal Pore Size
1.0 / 0.2 µm
Non-Fiber Releasing
This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Outlet Connection
Sanitary Flange
Outlet Connection Diameter
1-1/2 in.
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥15 L
Pore Size
1.0 / 0.2 µm
Seal Material
Silicone (SI)
Sterilization
3 autoclave cycles of 30 min @ 121 °C; not in-line steam sterilizable
Support Material
Polypropylene
Trade Name
Opticap®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Vent Cap Material
Polypropylene (PP)
Width