+852-3069 6950
css@gugent.com.hk
 

We have developed a unique portfolio of consumables, each adapted to the different feed water quality requirements and to your various applications. To maintain your water system’s performance, it’s critical to replace your purification cartridges on time and with genuine ISO 9001-certified parts.

Catalog No. Product Net Price
P2DVPPC01 Pellicon® 2 Mini Cassette with Durapore 0.65 µm Membrane, C screen, 0.1 m² 770 
Add to Cart
  • Catalogue Number
  • P2DVPPC01
  • Chemistry
  • Polyvinylidene Fluoride (PVDF)
  • Device Configuration
  • Mini Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • DVPP
  • Filter Type
  • Microfiltration
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 1.5 cm (0.6 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 20.6 cm (8.1 in)
  • Material Size
  • 1
  • Maximum Operating Temperature
  • 50˚C
  • Maximum Transmembrane Pressure
  • Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
  • Media
  • Durapore®
  • Membrane Area
  • 0.1 m²
  • pH Range
  • pH2 – pH11
  • Pore Size
  • 0.65 µm
  • Recirculation Rate
  • 4 to 7 L/min/m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type C screen (coarse screen)
  • Trade Name
  • Pellicon®
  • Width
  • 5.6 cm (2.2 in.)
P2DVPPC01 Pellicon® 2 Mini Cassette with Durapore 0.65 µm Membrane, C screen, 0.1 m² 770 
Add to Cart
  • Catalogue Number
  • P2DVPPC01
  • Chemistry
  • Polyvinylidene Fluoride (PVDF)
  • Device Configuration
  • Mini Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • DVPP
  • Filter Type
  • Microfiltration
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 1.5 cm (0.6 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 20.6 cm (8.1 in)
  • Material Size
  • 1
  • Maximum Operating Temperature
  • 50˚C
  • Maximum Transmembrane Pressure
  • Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
  • Media
  • Durapore®
  • Membrane Area
  • 0.1 m²
  • pH Range
  • pH2 – pH11
  • Pore Size
  • 0.65 µm
  • Recirculation Rate
  • 4 to 7 L/min/m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type C screen (coarse screen)
  • Trade Name
  • Pellicon®
  • Width
  • 5.6 cm (2.2 in.)
P2GVPPC01 Pellicon® 2 Mini Cassette with Durapore 0.22 µm Membrane, C screen, 0.1 m² 770 
Add to Cart
  • Catalogue Number
  • P2GVPPC01
  • Chemistry
  • Polyvinylidene Fluoride (PVDF)
  • Device Configuration
  • Mini Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • GVPP
  • Filter Type
  • Microfiltration
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 1.5 cm (0.6 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 20.6 cm (8.1 in)
  • Material Size
  • 1
  • Maximum Operating Temperature
  • 50˚C
  • Maximum Transmembrane Pressure
  • Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
  • Media
  • Durapore®
  • Membrane Area
  • 0.1 m²
  • pH Range
  • pH2 – pH11
  • Pore Size
  • 0.22 µm
  • Recirculation Rate
  • 4 to 7 L/min/m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type C screen (coarse screen)
  • Trade Name
  • Pellicon®
  • Width
  • 5.6 cm (2.2 in.)
P2GVPPC01 Pellicon® 2 Mini Cassette with Durapore 0.22 µm Membrane, C screen, 0.1 m² 770 
Add to Cart
  • Catalogue Number
  • P2GVPPC01
  • Chemistry
  • Polyvinylidene Fluoride (PVDF)
  • Device Configuration
  • Mini Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • GVPP
  • Filter Type
  • Microfiltration
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 1.5 cm (0.6 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 20.6 cm (8.1 in)
  • Material Size
  • 1
  • Maximum Operating Temperature
  • 50˚C
  • Maximum Transmembrane Pressure
  • Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
  • Media
  • Durapore®
  • Membrane Area
  • 0.1 m²
  • pH Range
  • pH2 – pH11
  • Pore Size
  • 0.22 µm
  • Recirculation Rate
  • 4 to 7 L/min/m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type C screen (coarse screen)
  • Trade Name
  • Pellicon®
  • Width
  • 5.6 cm (2.2 in.)
P2HVMPC01 Pellicon® 2 Mini Cassette with Durapore 0.45 µm Membrane, C screen, 0.1 m² 770 
Add to Cart
  • Catalogue Number
  • P2HVMPC01
  • Chemistry
  • Polyvinylidene Fluoride (PVDF)
  • Device Configuration
  • Mini Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • HVMP
  • Filter Type
  • Microfiltration
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 1.5 cm (0.6 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 20.6 cm (8.1 in)
  • Material Size
  • 1
  • Maximum Operating Temperature
  • 50˚C
  • Maximum Transmembrane Pressure
  • Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
  • Media
  • Durapore®
  • Membrane Area
  • 0.1 m²
  • pH Range
  • pH2 – pH11
  • Pore Size
  • 0.45 µm
  • Recirculation Rate
  • 4 to 7 L/min/m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type C screen (coarse screen)
  • Trade Name
  • Pellicon®
  • Width
  • 5.6 cm (2.2 in.)
P2HVMPC01 Pellicon® 2 Mini Cassette with Durapore 0.45 µm Membrane, C screen, 0.1 m² 770 
Add to Cart
  • Catalogue Number
  • P2HVMPC01
  • Chemistry
  • Polyvinylidene Fluoride (PVDF)
  • Device Configuration
  • Mini Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • HVMP
  • Filter Type
  • Microfiltration
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 1.5 cm (0.6 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 20.6 cm (8.1 in)
  • Material Size
  • 1
  • Maximum Operating Temperature
  • 50˚C
  • Maximum Transmembrane Pressure
  • Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
  • Media
  • Durapore®
  • Membrane Area
  • 0.1 m²
  • pH Range
  • pH2 – pH11
  • Pore Size
  • 0.45 µm
  • Recirculation Rate
  • 4 to 7 L/min/m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type C screen (coarse screen)
  • Trade Name
  • Pellicon®
  • Width
  • 5.6 cm (2.2 in.)
P2VVPPC01 Pellicon® 2 Mini Cassette with Durapore 0.1 µm Membrane, C screen, 0.1 m² 770 
Add to Cart
  • Catalogue Number
  • P2VVPPC01
  • Chemistry
  • Polyvinylidene Fluoride (PVDF)
  • Device Configuration
  • Mini Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • VVPP
  • Filter Type
  • Microfiltration
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 1.5 cm (0.6 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 20.6 cm (8.1 in)
  • Material Size
  • 1
  • Maximum Operating Temperature
  • 50˚C
  • Maximum Transmembrane Pressure
  • Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
  • Media
  • Durapore®
  • Membrane Area
  • 0.1 m²
  • pH Range
  • pH2 – pH11
  • Pore Size
  • 0.1 µm
  • Recirculation Rate
  • 4 to 7 L/min/m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type C screen (coarse screen)
  • Trade Name
  • Pellicon®
  • Width
  • 5.6 cm (2.2 in.)
P2VVPPC01 Pellicon® 2 Mini Cassette with Durapore 0.1 µm Membrane, C screen, 0.1 m² 770 
Add to Cart
  • Catalogue Number
  • P2VVPPC01
  • Chemistry
  • Polyvinylidene Fluoride (PVDF)
  • Device Configuration
  • Mini Cassette
  • Device Material
  • Polypropylene
  • Filter Code
  • VVPP
  • Filter Type
  • Microfiltration
  • Good Manufacturing Practices
  • These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Gravimetric Extractables
  • The extractables level was equal to or less than 1500 mg/m² after a water flush.
  • Height
  • 1.5 cm (0.6 in.)
  • Key Applications
  • Protein PurificationAnalytical Sample Prep
  • Length
  • 20.6 cm (8.1 in)
  • Material Size
  • 1
  • Maximum Operating Temperature
  • 50˚C
  • Maximum Transmembrane Pressure
  • Forward: 6.8 bar (100 psig) @ 30°C; Reverse: 0.3 bar (5 psig) maximum
  • Media
  • Durapore®
  • Membrane Area
  • 0.1 m²
  • pH Range
  • pH2 – pH11
  • Pore Size
  • 0.1 µm
  • Recirculation Rate
  • 4 to 7 L/min/m²
  • Screen Material
  • Polypropylene (PP)
  • Screen Type
  • Type C screen (coarse screen)
  • Trade Name
  • Pellicon®
  • Width
  • 5.6 cm (2.2 in.)
CN0601E06 Polygard-CN Cartridge Filter 10 in. 0.6 µm Code 0 Ethylene-Propylene 774 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 0 (2-222) O-rings
  • Cartridge Nominal Length
  • 10 in. (25 cm)
  • Catalogue Number
  • CN0601E06
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Filtration Area
  • 0.42 m²
  • Gravimetric Extractables
  • ≤50 mg after 24-h soak in water
  • Length
  • 10 in. (25 cm)
  • Material Size
  • 6
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 0.6 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥5 L
  • Pore Size
  • 0.6 µm
  • Sanitization
  • 30 min with hot water @ 80 °C
  • Seal Material
  • Ethylene Propylene
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Polygard®
  • Wettability
  • Hydrophilic
CN0601E06 Polygard-CN Cartridge Filter 10 in. 0.6 µm Code 0 Ethylene-Propylene 774 
Add to Cart
  • Bacterial Endotoxins
  • Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Cartridge Code
  • Code 0 (2-222) O-rings
  • Cartridge Nominal Length
  • 10 in. (25 cm)
  • Catalogue Number
  • CN0601E06
  • Chemistry
  • Polypropylene (PP)
  • Device Configuration
  • Cartridge
  • Device Material
  • Polypropylene
  • Diameter
  • 7.0 cm (2.75 in.)
  • Filtration Area
  • 0.42 m²
  • Gravimetric Extractables
  • ≤50 mg after 24-h soak in water
  • Length
  • 10 in. (25 cm)
  • Material Size
  • 6
  • Maximum Differential Pressure, bar (psid)
  • 4.8 bar (70 psid) @ 25 °C
  • Maximum Inlet Pressure, bar (psi)
  • 4.8 bar (70 psi) @ 25 °C
  • Nominal Pore Size
  • 0.6 µm
  • Oxidizable Substances
  • Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥5 L
  • Pore Size
  • 0.6 µm
  • Sanitization
  • 30 min with hot water @ 80 °C
  • Seal Material
  • Ethylene Propylene
  • Sterilization
  • 10 autoclave cycles or SIP @ 126 °C for 30 min
  • Trade Name
  • Polygard®
  • Wettability
  • Hydrophilic

Overview

Analytical Sample Preparation Membrane Filtration Devices


Trust Merck membrane filtration devices for the collection and preparation of samples, mobile phases, and buffers to obtain the highest quality results from downstream analysis.


Whether you need to collect, separate, or remove contaminants from air or fluid samples prior to downstream analysis, our broad selection of syringe filters, membranes, filter holders and related filtration devices ensures that we have the right solution for your application.


Filter Membranes

Millex® Syringe Filters

Filtration Holders & Accessories



Resources