CP1504S03
Lifegard™ Cartridge Filter 40 in. 1.0 µm Code 0
842
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤1.0 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Code
Code 0 (2-222) O-rings
Cartridge Nominal Length
40 in. (100 cm)
Catalogue Number
CP1504S03
Chemistry
Borosilicate Glass Fiber (BGF)
Device Configuration
Cartridge
Device Material
Polypropylene
Device Size
40 in.
Diameter
7.4 cm (2.9 in.)
Filter Grade
AP15
Filtration Area
1.52 m²
Format
Single Layer
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 250 mg per 10-inch cartridge after 24 hours in water at controlled room temperature.
Length
40 in. (100 cm)
Material Package
Double Easy-Open bag
Material Size
3
Maximum Differential Pressure, bar (psid)
3.5 bar (50 psid) @ 25 °C
Maximum Inlet Pressure, bar (psi)
3.5 bar (50 psi) @ 25 °C
Media
Lifegard™
Nominal Pore Size
1.0 µm
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥5 L
Pore Size
1.0 µm
Sanitization
30 min with hot water @ 80 °C
Seal Material
Silicone (SI)
Sterilization
10 autoclave cycles or SIP @ 121 °C for 30 min
Support Material
Polypropylene
Trade Name
Lifegard™
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 1.0 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
CP2004S03
Lifegard™ Cartridge Filter 40 in. 2.0 µm Code 0
842
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤1.0 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Code
Code 0 (2-222) O-rings
Cartridge Nominal Length
40 in. (100 cm)
Catalogue Number
CP2004S03
Chemistry
Borosilicate Glass Fiber (BGF)
Device Configuration
Cartridge
Device Material
Polypropylene
Device Size
40 in.
Diameter
7.4 cm (2.9 in.)
Filter Grade
AP20
Filtration Area
1.52 m²
Format
Single Layer
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 220 mg per 10-inch cartridge after 24 hours in water at controlled room temperature.
Length
40 in. (100 cm)
Material Package
Double Easy-Open bag
Material Size
3
Maximum Differential Pressure, bar (psid)
3.5 bar (50 psid) @ 25 °C
Maximum Inlet Pressure, bar (psi)
3.5 bar (50 psi) @ 25 °C
Media
Lifegard™
Nominal Pore Size
2.0 µm
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥5 L
Pore Size
2.0 µm
Sanitization
30 min with hot water @ 80 °C
Seal Material
Silicone (SI)
Sterilization
10 autoclave cycles or SIP @ 121 °C for 30 min
Support Material
Polypropylene
Trade Name
Lifegard™
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 1.0 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
CP2004S03
Lifegard™ Cartridge Filter 40 in. 2.0 µm Code 0
842
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤1.0 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Code
Code 0 (2-222) O-rings
Cartridge Nominal Length
40 in. (100 cm)
Catalogue Number
CP2004S03
Chemistry
Borosilicate Glass Fiber (BGF)
Device Configuration
Cartridge
Device Material
Polypropylene
Device Size
40 in.
Diameter
7.4 cm (2.9 in.)
Filter Grade
AP20
Filtration Area
1.52 m²
Format
Single Layer
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 220 mg per 10-inch cartridge after 24 hours in water at controlled room temperature.
Length
40 in. (100 cm)
Material Package
Double Easy-Open bag
Material Size
3
Maximum Differential Pressure, bar (psid)
3.5 bar (50 psid) @ 25 °C
Maximum Inlet Pressure, bar (psi)
3.5 bar (50 psi) @ 25 °C
Media
Lifegard™
Nominal Pore Size
2.0 µm
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥5 L
Pore Size
2.0 µm
Sanitization
30 min with hot water @ 80 °C
Seal Material
Silicone (SI)
Sterilization
10 autoclave cycles or SIP @ 121 °C for 30 min
Support Material
Polypropylene
Trade Name
Lifegard™
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 1.0 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
CP2074S03
Lifegard™ Cartridge Filter 40 in. 2.0 µm Code 7
842
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤1.0 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Code
Code 7 (2-226) O-ring and spear
Cartridge Nominal Length
40 in. (100 cm)
Catalogue Number
CP2074S03
Chemistry
Borosilicate Glass Fiber (BGF)
Device Configuration
Cartridge
Device Material
Polypropylene
Device Size
40 in.
Diameter
7.4 cm (2.9 in.)
Filter Grade
AP20
Filtration Area
1.52 m²
Format
Single Layer
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 220 mg per 10-inch cartridge after 24 hours in water at controlled room temperature.
Length
40 in. (100 cm)
Material Package
Double Easy-Open bag
Material Size
3
Maximum Differential Pressure, bar (psid)
3.5 bar (50 psid) @ 25 °C
Maximum Inlet Pressure, bar (psi)
3.5 bar (50 psi) @ 25 °C
Media
Lifegard™
Nominal Pore Size
2.0 µm
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥5 L
Pore Size
2.0 µm
Sanitization
30 min with hot water @ 80 °C
Seal Material
Silicone (SI)
Sterilization
10 autoclave cycles or SIP @ 121 °C for 30 min
Support Material
Polypropylene
Trade Name
Lifegard™
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 1.0 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
CP2074S03
Lifegard™ Cartridge Filter 40 in. 2.0 µm Code 7
842
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤1.0 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Code
Code 7 (2-226) O-ring and spear
Cartridge Nominal Length
40 in. (100 cm)
Catalogue Number
CP2074S03
Chemistry
Borosilicate Glass Fiber (BGF)
Device Configuration
Cartridge
Device Material
Polypropylene
Device Size
40 in.
Diameter
7.4 cm (2.9 in.)
Filter Grade
AP20
Filtration Area
1.52 m²
Format
Single Layer
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 220 mg per 10-inch cartridge after 24 hours in water at controlled room temperature.
Length
40 in. (100 cm)
Material Package
Double Easy-Open bag
Material Size
3
Maximum Differential Pressure, bar (psid)
3.5 bar (50 psid) @ 25 °C
Maximum Inlet Pressure, bar (psi)
3.5 bar (50 psi) @ 25 °C
Media
Lifegard™
Nominal Pore Size
2.0 µm
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥5 L
Pore Size
2.0 µm
Sanitization
30 min with hot water @ 80 °C
Seal Material
Silicone (SI)
Sterilization
10 autoclave cycles or SIP @ 121 °C for 30 min
Support Material
Polypropylene
Trade Name
Lifegard™
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 1.0 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
CN0371E06
Polygard-CN Cartridge Filter 10 in. 0.3 µm Code 7 Ethylene-Propylene
844
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Code
Code 7 (2-226) O-rings w/locking-tabs
Cartridge Nominal Length
10 in. (25 cm)
Catalogue Number
CN0371E06
Chemistry
Polypropylene (PP)
Device Configuration
Cartridge
Device Material
Polypropylene
Diameter
7.0 cm (2.75 in.)
Filtration Area
0.42 m²
Gravimetric Extractables
≤50 mg after 24-h soak in water
Length
10 in. (25 cm)
Material Size
6
Maximum Differential Pressure, bar (psid)
4.8 bar (70 psid) @ 25 °C
Maximum Inlet Pressure, bar (psi)
4.8 bar (70 psi) @ 25 °C
Nominal Pore Size
0.3 µm
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥5 L
Pore Size
0.3 µm
Sanitization
30 min with hot water @ 80 °C
Seal Material
Ethylene Propylene
Sterilization
10 autoclave cycles or SIP @ 126 °C for 30 min
Trade Name
Polygard®
Wettability
Hydrophilic
CN0371E06
Polygard-CN Cartridge Filter 10 in. 0.3 µm Code 7 Ethylene-Propylene
844
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Code
Code 7 (2-226) O-rings w/locking-tabs
Cartridge Nominal Length
10 in. (25 cm)
Catalogue Number
CN0371E06
Chemistry
Polypropylene (PP)
Device Configuration
Cartridge
Device Material
Polypropylene
Diameter
7.0 cm (2.75 in.)
Filtration Area
0.42 m²
Gravimetric Extractables
≤50 mg after 24-h soak in water
Length
10 in. (25 cm)
Material Size
6
Maximum Differential Pressure, bar (psid)
4.8 bar (70 psid) @ 25 °C
Maximum Inlet Pressure, bar (psi)
4.8 bar (70 psi) @ 25 °C
Nominal Pore Size
0.3 µm
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥5 L
Pore Size
0.3 µm
Sanitization
30 min with hot water @ 80 °C
Seal Material
Ethylene Propylene
Sterilization
10 autoclave cycles or SIP @ 126 °C for 30 min
Trade Name
Polygard®
Wettability
Hydrophilic
CN0371S06
Polygard-CN Cartridge Filter 10 in. 0.3 µm Code 7 Silicone
844
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Code
Code 7 (2-226) O-rings w/locking-tabs
Cartridge Nominal Length
10 in. (25 cm)
Catalogue Number
CN0371S06
Chemistry
Polypropylene (PP)
Device Configuration
Cartridge
Device Material
Polypropylene
Diameter
7.0 cm (2.75 in.)
Filtration Area
0.42 m²
Gravimetric Extractables
≤50 mg after 24-h soak in water
Length
10 in. (25 cm)
Material Size
6
Maximum Differential Pressure, bar (psid)
4.8 bar (70 psid) @ 25 °C
Maximum Inlet Pressure, bar (psi)
4.8 bar (70 psi) @ 25 °C
Nominal Pore Size
0.3 µm
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥5 L
Pore Size
0.3 µm
Sanitization
30 min with hot water @ 80 °C
Seal Material
Silicone (SI)
Sterilization
10 autoclave cycles or SIP @ 126 °C for 30 min
Trade Name
Polygard®
Wettability
Hydrophilic
CN1HF2E06
Polygard-CN Cartridge Filter 20 in. 10.0 µm Code F Ethylene-Propylene
844
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Code
Code F double open end w/flat gaskets
Cartridge Nominal Length
20 in. (50 cm)
Catalogue Number
CN1HF2E06
Chemistry
Polypropylene (PP)
Device Configuration
Cartridge
Device Material
Polypropylene
Diameter
7.0 cm (2.75 in.)
Filtration Area
0.84 m²
Gravimetric Extractables
≤100 mg after 24-h soak in water
Length
20 in. (50 cm)
Material Size
6
Maximum Differential Pressure, bar (psid)
4.8 bar (70 psid) @ 25 °C
Maximum Inlet Pressure, bar (psi)
4.8 bar (70 psi) @ 25 °C
Nominal Pore Size
10.0 µm
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥10 L
Pore Size
10.0 µm
Sanitization
30 min with hot water @ 80 °C
Seal Material
Ethylene Propylene
Sterilization
10 autoclave cycles or SIP @ 126 °C for 30 min
Trade Name
Polygard®
Wettability
Hydrophilic
CN1HF2E06
Polygard-CN Cartridge Filter 20 in. 10.0 µm Code F Ethylene-Propylene
844
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Code
Code F double open end w/flat gaskets
Cartridge Nominal Length
20 in. (50 cm)
Catalogue Number
CN1HF2E06
Chemistry
Polypropylene (PP)
Device Configuration
Cartridge
Device Material
Polypropylene
Diameter
7.0 cm (2.75 in.)
Filtration Area
0.84 m²
Gravimetric Extractables
≤100 mg after 24-h soak in water
Length
20 in. (50 cm)
Material Size
6
Maximum Differential Pressure, bar (psid)
4.8 bar (70 psid) @ 25 °C
Maximum Inlet Pressure, bar (psi)
4.8 bar (70 psi) @ 25 °C
Nominal Pore Size
10.0 µm
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥10 L
Pore Size
10.0 µm
Sanitization
30 min with hot water @ 80 °C
Seal Material
Ethylene Propylene
Sterilization
10 autoclave cycles or SIP @ 126 °C for 30 min
Trade Name
Polygard®
Wettability
Hydrophilic