CF3F01205
Kit: Milli-Q® Ion-Free (DI feedwater)
900
Add to Cart
Catalogue Number
CF3F01205
Material Size
1
CRK302006
Polygard-CR Cartridge Filter 20 in. 0.3 µm Code 0 Silicone
901
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Code
Code 0 (2-222) O-rings
Cartridge Nominal Length
20 in. (50 cm)
Catalogue Number
CRK302006
Chemistry
Polypropylene (PP)
Device Configuration
Cartridge
Device Material
Polypropylene
Diameter
7.0 cm (2.75 in.)
Gravimetric Extractables
≤50 mg after 24-h soak in water
Length
20 in. (50 cm)
Material Size
6
Maximum Differential Pressure, bar (psid)
4.8 bar (70 psid) @ 25 °C
Maximum Inlet Pressure, bar (psi)
4.8 bar (70 psi) @ 25 °C
Nominal Pore Size
0.3 µm
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥10 L
Pore Size
0.3 µm
Sanitization
30 min with hot water @ 80 °C
Seal Material
Silicone (SI)
Sterilization
10 autoclave cycles or SIP @ 126 °C for 30 min
Trade Name
Polygard®
Wettability
Hydrophilic
CRK302006
Polygard-CR Cartridge Filter 20 in. 0.3 µm Code 0 Silicone
901
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Code
Code 0 (2-222) O-rings
Cartridge Nominal Length
20 in. (50 cm)
Catalogue Number
CRK302006
Chemistry
Polypropylene (PP)
Device Configuration
Cartridge
Device Material
Polypropylene
Diameter
7.0 cm (2.75 in.)
Gravimetric Extractables
≤50 mg after 24-h soak in water
Length
20 in. (50 cm)
Material Size
6
Maximum Differential Pressure, bar (psid)
4.8 bar (70 psid) @ 25 °C
Maximum Inlet Pressure, bar (psi)
4.8 bar (70 psi) @ 25 °C
Nominal Pore Size
0.3 µm
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥10 L
Pore Size
0.3 µm
Sanitization
30 min with hot water @ 80 °C
Seal Material
Silicone (SI)
Sterilization
10 autoclave cycles or SIP @ 126 °C for 30 min
Trade Name
Polygard®
Wettability
Hydrophilic
CRK302V06
Polygard-CR Cartridge Filter 20 in. 0.3 µm Code 0 Fluoroelastomer
901
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Code
Code 0 (2-222) O-rings
Cartridge Nominal Length
20 in. (50 cm)
Catalogue Number
CRK302V06
Chemistry
Polypropylene (PP)
Device Configuration
Cartridge
Device Material
Polypropylene
Diameter
7.0 cm (2.75 in.)
Gravimetric Extractables
≤50 mg after 24-h soak in water
Length
20 in. (50 cm)
Material Size
6
Maximum Differential Pressure, bar (psid)
4.8 bar (70 psid) @ 25 °C
Maximum Inlet Pressure, bar (psi)
4.8 bar (70 psi) @ 25 °C
Nominal Pore Size
0.3 µm
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥10 L
Pore Size
0.3 µm
Sanitization
30 min with hot water @ 80 °C
Seal Material
Fluorocarbon rubber
Sterilization
10 autoclave cycles or SIP @ 126 °C for 30 min
Trade Name
Polygard®
Wettability
Hydrophilic
CRK352006
Polygard-CR Cartridge Filter 20 in. 0.3 µm Code 5 Silicone
901
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Code
Code 5 (2-222) O-rings and spear
Cartridge Nominal Length
20 in. (50 cm)
Catalogue Number
CRK352006
Chemistry
Polypropylene (PP)
Device Configuration
Cartridge
Device Material
Polypropylene
Diameter
7.0 cm (2.75 in.)
Gravimetric Extractables
≤50 mg after 24-h soak in water
Length
20 in. (50 cm)
Material Size
6
Maximum Differential Pressure, bar (psid)
4.8 bar (70 psid) @ 25 °C
Maximum Inlet Pressure, bar (psi)
4.8 bar (70 psi) @ 25 °C
Nominal Pore Size
0.3 µm
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥10 L
Pore Size
0.3 µm
Sanitization
30 min with hot water @ 80 °C
Seal Material
Silicone (SI)
Sterilization
10 autoclave cycles or SIP @ 126 °C for 30 min
Trade Name
Polygard®
Wettability
Hydrophilic
CRK352006
Polygard-CR Cartridge Filter 20 in. 0.3 µm Code 5 Silicone
901
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Code
Code 5 (2-222) O-rings and spear
Cartridge Nominal Length
20 in. (50 cm)
Catalogue Number
CRK352006
Chemistry
Polypropylene (PP)
Device Configuration
Cartridge
Device Material
Polypropylene
Diameter
7.0 cm (2.75 in.)
Gravimetric Extractables
≤50 mg after 24-h soak in water
Length
20 in. (50 cm)
Material Size
6
Maximum Differential Pressure, bar (psid)
4.8 bar (70 psid) @ 25 °C
Maximum Inlet Pressure, bar (psi)
4.8 bar (70 psi) @ 25 °C
Nominal Pore Size
0.3 µm
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥10 L
Pore Size
0.3 µm
Sanitization
30 min with hot water @ 80 °C
Seal Material
Silicone (SI)
Sterilization
10 autoclave cycles or SIP @ 126 °C for 30 min
Trade Name
Polygard®
Wettability
Hydrophilic
CRK372006
Polygard-CR Cartridge Filter 20 in. 0.3 µm Code 7 Silicone
901
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Code
Code 7 (2-226) O-rings w/locking-tabs
Cartridge Nominal Length
20 in. (50 cm)
Catalogue Number
CRK372006
Chemistry
Polypropylene (PP)
Device Configuration
Cartridge
Device Material
Polypropylene
Diameter
7.0 cm (2.75 in.)
Gravimetric Extractables
≤50 mg after 24-h soak in water
Length
20 in. (50 cm)
Material Size
6
Maximum Differential Pressure, bar (psid)
4.8 bar (70 psid) @ 25 °C
Maximum Inlet Pressure, bar (psi)
4.8 bar (70 psi) @ 25 °C
Nominal Pore Size
0.3 µm
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥10 L
Pore Size
0.3 µm
Sanitization
30 min with hot water @ 80 °C
Seal Material
Silicone (SI)
Sterilization
10 autoclave cycles or SIP @ 126 °C for 30 min
Trade Name
Polygard®
Wettability
Hydrophilic
CRK372006
Polygard-CR Cartridge Filter 20 in. 0.3 µm Code 7 Silicone
901
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Code
Code 7 (2-226) O-rings w/locking-tabs
Cartridge Nominal Length
20 in. (50 cm)
Catalogue Number
CRK372006
Chemistry
Polypropylene (PP)
Device Configuration
Cartridge
Device Material
Polypropylene
Diameter
7.0 cm (2.75 in.)
Gravimetric Extractables
≤50 mg after 24-h soak in water
Length
20 in. (50 cm)
Material Size
6
Maximum Differential Pressure, bar (psid)
4.8 bar (70 psid) @ 25 °C
Maximum Inlet Pressure, bar (psi)
4.8 bar (70 psi) @ 25 °C
Nominal Pore Size
0.3 µm
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥10 L
Pore Size
0.3 µm
Sanitization
30 min with hot water @ 80 °C
Seal Material
Silicone (SI)
Sterilization
10 autoclave cycles or SIP @ 126 °C for 30 min
Trade Name
Polygard®
Wettability
Hydrophilic
CRK372V06
Polygard-CR Cartridge Filter 20 in. 0.3 µm Code 7 Fluoroelastomer
901
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Code
Code 7 (2-226) O-rings w/locking-tabs
Cartridge Nominal Length
20 in. (50 cm)
Catalogue Number
CRK372V06
Chemistry
Polypropylene (PP)
Device Configuration
Cartridge
Device Material
Polypropylene
Diameter
7.0 cm (2.75 in.)
Gravimetric Extractables
≤50 mg after 24-h soak in water
Length
20 in. (50 cm)
Material Size
6
Maximum Differential Pressure, bar (psid)
4.8 bar (70 psid) @ 25 °C
Maximum Inlet Pressure, bar (psi)
4.8 bar (70 psi) @ 25 °C
Nominal Pore Size
0.3 µm
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥10 L
Pore Size
0.3 µm
Sanitization
30 min with hot water @ 80 °C
Seal Material
Fluorocarbon rubber
Sterilization
10 autoclave cycles or SIP @ 126 °C for 30 min
Trade Name
Polygard®
Wettability
Hydrophilic
CRK3F2C06
Polygard-CR Cartridge Filter 20 in. 0.3 µm Code F Short
901
Add to Cart
Bacterial Endotoxins
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Cartridge Code
Code F double open end w/flat gaskets
Cartridge Nominal Length
20 in. (50 cm)
Catalogue Number
CRK3F2C06
Chemistry
Polypropylene (PP)
Device Configuration
Cartridge
Device Material
Polypropylene
Diameter
7.0 cm (2.75 in.)
Gravimetric Extractables
≤50 mg after 24-h soak in water
Length
20 in. (50 cm)
Material Size
6
Maximum Differential Pressure, bar (psid)
4.8 bar (70 psid) @ 25 °C
Maximum Inlet Pressure, bar (psi)
4.8 bar (70 psi) @ 25 °C
Nominal Pore Size
0.3 µm
Oxidizable Substances
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥10 L
Pore Size
0.3 µm
Sanitization
30 min with hot water @ 80 °C
Seal Material
Silicone (SI)
Sterilization
Do not autoclave
Trade Name
Polygard®
Wettability
Hydrophilic