+852-3069 6950
css@gugent.com.hk
 

With industry-leading sterile filtration devices based on 60 years of membrane filtration expertise, MilliporeSigma supports conventional and emerging formats for cell culture. The MilliporeSigma Cell Culture Solutions portfolio features over 20,000 high-quality tools to cultivate consistency in your cell culture workflow.

Cell Preparation: Tools that you need to minimize contamination risk and maximize workflow efficiency while preparing your media for cell culture.

Cell Growth: Whatever your cell culture growth needs, we have a plate, insert or vessel that can help you obtain the optimal cell culture results.

Cell Analysis: In addition to our solid base in assay tools and products, we offer new, novel cell culture technologies and cell culture platforms for high content data collection and analysis.

Catalog No. Product Net Price
MSVMHTS0A Droplet Trap Array 319 
Add to Cart
  • Catalogue Number
  • MSVMHTS0A
  • Material Size
  • 1
  • Trade Name
  • MultiScreen
S384SEQ10 MultiScreen SEQ384 Filter Plate 792 
Add to Cart
  • Automation Compatible
  • No
  • Catalogue Number
  • S384SEQ10
  • Chemistry
  • Proprietary
  • Color Code
  • Clear
  • Components
  • Does not include reagents
  • Device Material
  • Styrene
  • Filter Code
  • SEQ
  • Key Applications
  • Dye Terminator Removal
  • Material Size
  • 10
  • Number of Wells
  • 384
  • Pore Size
  • Proprietary
  • Sterility
  • Non-Sterile
  • Trade Name
  • MultiScreen
  • Volume
  • 100 µL
S384SEQ10 MultiScreen SEQ384 Filter Plate 792 
Add to Cart
  • Automation Compatible
  • No
  • Catalogue Number
  • S384SEQ10
  • Chemistry
  • Proprietary
  • Color Code
  • Clear
  • Components
  • Does not include reagents
  • Device Material
  • Styrene
  • Filter Code
  • SEQ
  • Key Applications
  • Dye Terminator Removal
  • Material Size
  • 10
  • Number of Wells
  • 384
  • Pore Size
  • Proprietary
  • Sterility
  • Non-Sterile
  • Trade Name
  • MultiScreen
  • Volume
  • 100 µL
S384SEQ50 MultiScreen SEQ384 Filter Plate 2946 
Add to Cart
  • Automation Compatible
  • No
  • Catalogue Number
  • S384SEQ50
  • Chemistry
  • Proprietary
  • Color Code
  • Clear
  • Components
  • Does not include reagents
  • Device Material
  • Styrene
  • Filter Code
  • SEQ
  • Key Applications
  • Dye Terminator Removal
  • Material Size
  • 50
  • Number of Wells
  • 384
  • Pore Size
  • Proprietary
  • Sterility
  • Non-Sterile
  • Trade Name
  • MultiScreen
  • Volume
  • 100 µL
S384SEQ50 MultiScreen SEQ384 Filter Plate 2946 
Add to Cart
  • Automation Compatible
  • No
  • Catalogue Number
  • S384SEQ50
  • Chemistry
  • Proprietary
  • Color Code
  • Clear
  • Components
  • Does not include reagents
  • Device Material
  • Styrene
  • Filter Code
  • SEQ
  • Key Applications
  • Dye Terminator Removal
  • Material Size
  • 50
  • Number of Wells
  • 384
  • Pore Size
  • Proprietary
  • Sterility
  • Non-Sterile
  • Trade Name
  • MultiScreen
  • Volume
  • 100 µL
MX-PLATE 96-well Filter Plate 45 
Add to Cart
  • Automation Compatible
  • No
  • Catalogue Number
  • MX-PLATE
  • Color Code
  • Not Applicable
  • Key Applications
  • Multiplexing
  • Material Size
  • 2 plates
  • Number of Wells
  • 96
  • Sterility
  • Non-Sterile
  • Trade Name
  • MILLIPLEX
PICM01250 Millicell Cell Culture Insert, 12 mm, hydrophilic PTFE, 0.4 µm 194 
Add to Cart
  • Background Information
  • With Millicell inserts, attachment or suspension cells can access media from both their apical and basolateral sides. Cell growth, structure, and function more closely mimic what occurs in vivo. In addition, Millicell inserts make it possible to study both sides of the cell monolayer.Millicell inserts are available for 24-, 12-, or 6-well plates. The inserts are easily prepared for SEM and TEM visualizing techniques, and they are compatible with cellular and/or fluorescent stains.Insert Formats:Millicell Hanging Inserts: Preloaded in receivers or available standalone - For co-culturing and permeability assays - Unique design allows easier basolateral access than other hanging inserts with less risk of contamination - Available in 5 pore sizes and 3 diameters, including a 1 µm pore size that is optically transparent for better visualization by microscopy - NEW: Available preloaded in 24-well receiver plates or as individual inserts in 3 diameters Millicell Standing Inserts: - Promotes excellent cell growth and provides an exceptional opportunity for cell studies - Available with Biopore (PTFE) membrane, MF-Millipore (mixed cellulose esters) membrane, and polycarbonate membrane Millicell Organotypic Insert: - For high cell viability and superior study of three dimensional explant structure - Lower height allows them to fit inside a standard petri dish - The Biopore™ (PTFE) membrane provides high viability—for as long as 40 days—and excellent trans-membrane oxygen transport - The membrane is optically clear and optimized for long-term organotypic explant maintenance Membrane Types:Biopore Membrane (hydrophilic PTFE) - For low protein-binding, live cell viewing, and immunofluorescent applicationsMF-Millipore™ Membrane (mixed cellulose esters) - For exceptional anatomical and functional polarizationIsopore™ Membrane (polycarbonate) - For growth of attachment-dependent cells without matrixPET Membrane (polyethylene terephthalate) - For growth of attachment-dependent cells without matrixWith Millicell® inserts, adherent or suspension cells can access media from both their apical and basolateral sides. Cell growth, structure, and function more closely mimic what occurs in vivo. In addition, Millicell® inserts make it possible to study both sides of the cell monolayer.ApplicationsCell Attachment, Cell Growth, Cell Differentiation , Immunocytochemistry
  • Catalogue Number
  • PICM01250
  • Chemistry
  • References Product Information Device Configuration
  • Device Configuration
  • 24-well plate
  • Device Material
  • Polystyrene
  • Filter Code
  • CM
  • Filter Diameter (⌀)
  • 12 mm
  • Filtration Area
  • 0.6 cm²
  • Height
  • 10.5 mm
  • Key Applications
  • Cell AttachmentCell CultureCell DifferentiationFluorescenceLow Protein Binding
  • Material Package
  • Individually blister packaged
  • Material Size
  • 50
  • Maximum Operating Temperature
  • 50 °C
  • Media
  • Biopore®
  • Number of Wells
  • 1
  • Pore Size
  • 0.4 µm
  • Stem Cell Type
  • Mouse Embryonic Stem CellsHuman Embryonic Stem CellsMesenchymal Stem CellsNeural Stem CellsHematopoietic Stem CellsEpithelial CellsPancreatic Stem CellsCardiac Stem CellsInduced Pluripotent Stem Cells
  • Sterility
  • Sterile
  • Trade Name
  • Millicell
PICM03050 Millicell Cell Culture Insert, 30 mm, hydrophilic PTFE, 0.4 µm 275 
Add to Cart
  • Background Information
  • With Millicell inserts, attachment or suspension cells can access media from both their apical and basolateral sides. Cell growth, structure, and function more closely mimic what occurs in vivo. In addition, Millicell inserts make it possible to study both sides of the cell monolayer.Millicell inserts are available for 24-, 12-, or 6-well plates. The inserts are easily prepared for SEM and TEM visualizing techniques, and they are compatible with cellular and/or fluorescent stains.Insert Formats:Millicell Hanging Inserts: Preloaded in receivers or available standalone - For co-culturing and permeability assays - Unique design allows easier basolateral access than other hanging inserts with less risk of contamination - Available in 5 pore sizes and 3 diameters, including a 1 µm pore size that is optically transparent for better visualization by microscopy - NEW: Available preloaded in 24-well receiver plates or as individual inserts in 3 diameters Millicell Standing Inserts: - Promotes excellent cell growth and provides an exceptional opportunity for cell studies - Available with Biopore (PTFE) membrane, MF-Millipore (mixed cellulose esters) membrane, and polycarbonate membrane Millicell Organotypic Insert: - For high cell viability and superior study of three dimensional explant structure - Lower height allows them to fit inside a standard petri dish - The Biopore™ (PTFE) membrane provides high viability—for as long as 40 days—and excellent trans-membrane oxygen transport - The membrane is optically clear and optimized for long-term organotypic explant maintenance Membrane Types:Biopore Membrane (hydrophilic PTFE) - For low protein-binding, live cell viewing, and immunofluorescent applicationsMF-Millipore™ Membrane (mixed cellulose esters) - For exceptional anatomical and functional polarizationIsopore™ Membrane (polycarbonate) - For growth of attachment-dependent cells without matrixPET Membrane (polyethylene terephthalate) - For growth of attachment-dependent cells without matrixWith Millicell® inserts, adherent or suspension cells can access media from both their apical and basolateral sides. Cell growth, structure, and function more closely mimic what occurs in vivo. In addition, Millicell® inserts make it possible to study both sides of the cell monolayer.ApplicationsCell Attachment, Cell Growth, Cell Differentiation , Immunocytochemistry
  • Catalogue Number
  • PICM03050
  • Chemistry
  • References Product Information Device Configuration
  • Device Configuration
  • 6-well plate
  • Device Material
  • Polystyrene
  • Diameter
  • 3.15 cm
  • Filter Code
  • CM
  • Filter Diameter (⌀)
  • 30 mm
  • Filtration Area
  • 4.2 cm²
  • Height
  • 13 mm
  • Key Applications
  • Cell AttachmentCell CultureCell DifferentiationFluorescenceLow Protein Binding
  • Material Package
  • Individually blister packaged
  • Material Size
  • 50
  • Maximum Operating Temperature
  • 50 °C
  • Media
  • Biopore®
  • Number of Wells
  • 1
  • Pore Size
  • 0.4 µm
  • Stem Cell Type
  • Mouse Embryonic Stem CellsHuman Embryonic Stem CellsMesenchymal Stem CellsNeural Stem CellsHematopoietic Stem CellsEpithelial CellsPancreatic Stem CellsCardiac Stem CellsInduced Pluripotent Stem Cells
  • Sterility
  • Sterile
  • Trade Name
  • Millicell
PICM0RG50 Millicell Cell Culture Insert, 30 mm, hydrophilic PTFE, 0.4 µm 325 
Add to Cart
  • Background Information
  • With Millicell inserts, attachment or suspension cells can access media from both their apical and basolateral sides. Cell growth, structure, and function more closely mimic what occurs in vivo. In addition, Millicell inserts make it possible to study both sides of the cell monolayer.Millicell inserts are available for 24-, 12-, or 6-well plates. The inserts are easily prepared for SEM and TEM visualizing techniques, and they are compatible with cellular and/or fluorescent stains.Insert Formats:Millicell Hanging Inserts: Preloaded in receivers or available standalone - For co-culturing and permeability assays - Unique design allows easier basolateral access than other hanging inserts with less risk of contamination - Available in 5 pore sizes and 3 diameters, including a 1 µm pore size that is optically transparent for better visualization by microscopy - NEW: Available preloaded in 24-well receiver plates or as individual inserts in 3 diameters Millicell Standing Inserts: - Promotes excellent cell growth and provides an exceptional opportunity for cell studies - Available with Biopore (PTFE) membrane, MF-Millipore (mixed cellulose esters) membrane, and polycarbonate membrane Millicell Organotypic Insert: - For high cell viability and superior study of three dimensional explant structure - Lower height allows them to fit inside a standard petri dish - The Biopore™ (PTFE) membrane provides high viability—for as long as 40 days—and excellent trans-membrane oxygen transport - The membrane is optically clear and optimized for long-term organotypic explant maintenance Membrane Types:Biopore Membrane (hydrophilic PTFE) - For low protein-binding, live cell viewing, and immunofluorescent applicationsMF-Millipore™ Membrane (mixed cellulose esters) - For exceptional anatomical and functional polarizationIsopore™ Membrane (polycarbonate) - For growth of attachment-dependent cells without matrixPET Membrane (polyethylene terephthalate) - For growth of attachment-dependent cells without matrixWith Millicell® inserts, adherent or suspension cells can access media from both their apical and basolateral sides. Cell growth, structure, and function more closely mimic what occurs in vivo. In addition, Millicell® inserts make it possible to study both sides of the cell monolayer.ApplicationsCell Attachment, Cell Growth, Cell Differentiation , Immunocytochemistry
  • Catalogue Number
  • PICM0RG50
  • Chemistry
  • References Product Information Device Configuration
  • Device Configuration
  • 6-well plate
  • Device Material
  • Polystyrene
  • Diameter
  • 3.15 cm
  • Filter Code
  • CM
  • Filter Diameter (⌀)
  • 30 mm
  • Filtration Area
  • 4.2 cm²
  • Height
  • 5 mm
  • Key Applications
  • Cell AttachmentCell CultureCell DifferentiationFluorescenceLow Protein Binding
  • Material Package
  • Individually blister packaged
  • Material Size
  • 50
  • Maximum Operating Temperature
  • 50 °C
  • Media
  • Biopore®
  • Number of Wells
  • 1
  • Pore Size
  • 0.4 µm
  • Stem Cell Type
  • Mouse Embryonic Stem CellsHuman Embryonic Stem CellsMesenchymal Stem CellsNeural Stem CellsHematopoietic Stem CellsEpithelial CellsPancreatic Stem CellsCardiac Stem CellsInduced Pluripotent Stem Cells
  • Sterility
  • Sterile
  • Trade Name
  • Millicell
ELI-006-H IL-5 ELISPOT Antibody Pair, Human 539 
Add to Cart
  • Catalogue Number
  • ELI-006-H
  • Components
  • • Human IL-5 Capture Antibody, clone TRFK5. Quantity: 500 µg.• Human IL-5 Detection Antibody, clone JES1-5A10. Quantity: 100 µg.• Streptavidin Alkaline Phosphatase. Quantity: 55 μL.
  • Format
  • Purified
  • Key Applications
  • ELISA
  • Material Package
  • Sufficient reagents for five, 96-well plates.
  • Material Size
  • 1 kit
  • Overview
  • Interleukin 5 (IL-5) is a hematopoietic growth factor that is primarily produced by activated T lymphocytes, and is approximately 70% homologically identical in both human and mouse. IL-5 has been shown to promote the growth of immature hematopoietic BFU-E progenitors, as well as stimulate the activation and differentiation of eosinophils, and promote the generation of cytotoxic lymphocytes. When production levels of this growth factor become elevated, IL-5 has also been shown to be linked to asthmatic conditions in both human and mouse models. The Millipore human IL-5 ELISPOT Antibody Pair provides a sensitive and highly reliable method for the detection of IL-5 secreting cells at the single cell level.
  • Storage Conditions
  • Maintain refrigerated at 2-8°C for up to six months from the date of receipt.