MN725850.60
GC column, Low polar, OPTIMA XLB, 60 m L, 0.25 mm ID, 0.25 µm df
Special offer
Add to Cart
Method
Gas chromatography (GC)
Composition
Proprietary
Recommended application(s)
Gas chromatography, GC, PCB, Pesticides, Trace analyses
Storage temperature
RT
Hazardous material
No
Scope of delivery
1x GC column coiled/wound on metal cage, user manual, certificate of analysis
Type
GC column
Brand
OPTIMA
Phase
OPTIMA XLB
USP listing
Not available or proprietary
Polarity
Low polar
Column inner diameter
0.25 mm
Film thickness
0.25 µm
Column length
60 m
Tmax isotherm
340 °C
Tmax temp. program
360 °C
Housing type
Wall coated open tubular (WCOT) capillary column, internal wall of capillary is coated with a very fine film of liquid stationary phase
Hardware
Fused Silica coated with polyimide coiled/wound on metal cage
Cage size
7" (inch)
Integrated precolumn
No
MN726630.30
GC column, Mid-polar, OPTIMA 1701 MS, 30 m L, 0.25 mm ID, 0.25 µm df
Special offer
Add to Cart
Method
Gas chromatography (GC)
Composition
Silarylene phase with very low bleeding - polarity similar to 14 % cyanopropylphenyl – 86 % dimethylpolysiloxane
Recommended application(s)
Blood alcohol, Environmental analysis (EPA methods for PAHs, PCBs and pesticides), Gas chromatography, GC
Storage temperature
RT
Hazardous material
No
Scope of delivery
1x GC column coiled/wound on metal cage, user manual, certificate of analysis
Type
GC column
Brand
OPTIMA
Phase
OPTIMA 1701 MS
USP listing
G46
Polarity
Mid-polar
Column inner diameter
0.25 mm
Film thickness
0.25 µm
Column length
30 m
Tmax isotherm
280 °C
Tmax temp. program
300 °C
Housing type
Wall coated open tubular (WCOT) capillary column, internal wall of capillary is coated with a very fine film of liquid stationary phase
Hardware
Fused Silica coated with polyimide coiled/wound on metal cage
Cage size
7" (inch)
Integrated precolumn
No
MN726631.30
GC column, Mid-polar, OPTIMA 1701 MS, 30 m L, 0.25 mm ID, 0.5 µm df
Special offer
Add to Cart
Method
Gas chromatography (GC)
Composition
Silarylene phase with very low bleeding - polarity similar to 14 % cyanopropylphenyl – 86 % dimethylpolysiloxane
Recommended application(s)
Blood alcohol, Environmental analysis (EPA methods for PAHs, PCBs and pesticides), Gas chromatography, GC
Storage temperature
RT
Hazardous material
No
Scope of delivery
1x GC column coiled/wound on metal cage, user manual, certificate of analysis
Type
GC column
Brand
OPTIMA
Phase
OPTIMA 1701 MS
USP listing
G46
Polarity
Mid-polar
Column inner diameter
0.25 mm
Film thickness
0.5 µm
Column length
30 m
Tmax isotherm
280 °C
Tmax temp. program
300 °C
Housing type
Wall coated open tubular (WCOT) capillary column, internal wall of capillary is coated with a very fine film of liquid stationary phase
Hardware
Fused Silica coated with polyimide coiled/wound on metal cage
Cage size
7" (inch)
Integrated precolumn
No
MN726633.30
GC column, Mid-polar, OPTIMA 1701 MS, 30 m L, 0.32 mm ID, 0.25 µm df
Special offer
Add to Cart
Method
Gas chromatography (GC)
Composition
Silarylene phase with very low bleeding - polarity similar to 14 % cyanopropylphenyl – 86 % dimethylpolysiloxane
Recommended application(s)
Blood alcohol, Environmental analysis (EPA methods for PAHs, PCBs and pesticides), Gas chromatography, GC
Storage temperature
RT
Hazardous material
No
Scope of delivery
1x GC column coiled/wound on metal cage, user manual, certificate of analysis
Type
GC column
Brand
OPTIMA
Phase
OPTIMA 1701 MS
USP listing
G46
Polarity
Mid-polar
Column inner diameter
0.32 mm
Film thickness
0.25 µm
Column length
30 m
Tmax isotherm
280 °C
Tmax temp. program
300 °C
Housing type
Wall coated open tubular (WCOT) capillary column, internal wall of capillary is coated with a very fine film of liquid stationary phase
Hardware
Fused Silica coated with polyimide coiled/wound on metal cage
Cage size
7" (inch)
Integrated precolumn
No
MN726634.30
GC column, Mid-polar, OPTIMA 1701 MS, 30 m L, 0.32 mm ID, 0.5 µm df
Special offer
Add to Cart
Method
Gas chromatography (GC)
Composition
Silarylene phase with very low bleeding - polarity similar to 14 % cyanopropylphenyl – 86 % dimethylpolysiloxane
Recommended application(s)
Blood alcohol, Environmental analysis (EPA methods for PAHs, PCBs and pesticides), Gas chromatography, GC
Storage temperature
RT
Hazardous material
No
Scope of delivery
1x GC column coiled/wound on metal cage, user manual, certificate of analysis
Type
GC column
Brand
OPTIMA
Phase
OPTIMA 1701 MS
USP listing
G46
Polarity
Mid-polar
Column inner diameter
0.32 mm
Film thickness
0.5 µm
Column length
30 m
Tmax isotherm
280 °C
Tmax temp. program
300 °C
Housing type
Wall coated open tubular (WCOT) capillary column, internal wall of capillary is coated with a very fine film of liquid stationary phase
Hardware
Fused Silica coated with polyimide coiled/wound on metal cage
Cage size
7" (inch)
Integrated precolumn
No
MN726630.60
GC column, Mid-polar, OPTIMA 1701 MS, 60 m L, 0.25 mm ID, 0.25 µm df
Special offer
Add to Cart
Method
Gas chromatography (GC)
Composition
Silarylene phase with very low bleeding - polarity similar to 14 % cyanopropylphenyl – 86 % dimethylpolysiloxane
Recommended application(s)
Blood alcohol, Environmental analysis (EPA methods for PAHs, PCBs and pesticides), Gas chromatography, GC
Storage temperature
RT
Hazardous material
No
Scope of delivery
1x GC column coiled/wound on metal cage, user manual, certificate of analysis
Type
GC column
Brand
OPTIMA
Phase
OPTIMA 1701 MS
USP listing
G46
Polarity
Mid-polar
Column inner diameter
0.25 mm
Film thickness
0.25 µm
Column length
60 m
Tmax isotherm
280 °C
Tmax temp. program
300 °C
Housing type
Wall coated open tubular (WCOT) capillary column, internal wall of capillary is coated with a very fine film of liquid stationary phase
Hardware
Fused Silica coated with polyimide coiled/wound on metal cage
Cage size
7" (inch)
Integrated precolumn
No
MN726631.60
GC column, Mid-polar, OPTIMA 1701 MS, 60 m L, 0.25 mm ID, 0.5 µm df
Special offer
Add to Cart
Method
Gas chromatography (GC)
Composition
Silarylene phase with very low bleeding - polarity similar to 14 % cyanopropylphenyl – 86 % dimethylpolysiloxane
Recommended application(s)
Blood alcohol, Environmental analysis (EPA methods for PAHs, PCBs and pesticides), Gas chromatography, GC
Storage temperature
RT
Hazardous material
No
Scope of delivery
1x GC column coiled/wound on metal cage, user manual, certificate of analysis
Type
GC column
Brand
OPTIMA
Phase
OPTIMA 1701 MS
USP listing
G46
Polarity
Mid-polar
Column inner diameter
0.25 mm
Film thickness
0.5 µm
Column length
60 m
Tmax isotherm
280 °C
Tmax temp. program
300 °C
Housing type
Wall coated open tubular (WCOT) capillary column, internal wall of capillary is coated with a very fine film of liquid stationary phase
Hardware
Fused Silica coated with polyimide coiled/wound on metal cage
Cage size
7" (inch)
Integrated precolumn
No
MN726633.60
GC column, Mid-polar, OPTIMA 1701 MS, 60 m L, 0.32 mm ID, 0.25 µm df
Special offer
Add to Cart
Method
Gas chromatography (GC)
Composition
Silarylene phase with very low bleeding - polarity similar to 14 % cyanopropylphenyl – 86 % dimethylpolysiloxane
Recommended application(s)
Blood alcohol, Environmental analysis (EPA methods for PAHs, PCBs and pesticides), Gas chromatography, GC
Storage temperature
RT
Hazardous material
No
Scope of delivery
1x GC column coiled/wound on metal cage, user manual, certificate of analysis
Type
GC column
Brand
OPTIMA
Phase
OPTIMA 1701 MS
USP listing
G46
Polarity
Mid-polar
Column inner diameter
0.32 mm
Film thickness
0.25 µm
Column length
60 m
Tmax isotherm
280 °C
Tmax temp. program
300 °C
Housing type
Wall coated open tubular (WCOT) capillary column, internal wall of capillary is coated with a very fine film of liquid stationary phase
Hardware
Fused Silica coated with polyimide coiled/wound on metal cage
Cage size
7" (inch)
Integrated precolumn
No
MN726634.60
GC column, Mid-polar, OPTIMA 1701 MS, 60 m L, 0.32 mm ID, 0.5 µm df
Special offer
Add to Cart
Method
Gas chromatography (GC)
Composition
Silarylene phase with very low bleeding - polarity similar to 14 % cyanopropylphenyl – 86 % dimethylpolysiloxane
Recommended application(s)
Blood alcohol, Environmental analysis (EPA methods for PAHs, PCBs and pesticides), Gas chromatography, GC
Storage temperature
RT
Hazardous material
No
Scope of delivery
1x GC column coiled/wound on metal cage, user manual, certificate of analysis
Type
GC column
Brand
OPTIMA
Phase
OPTIMA 1701 MS
USP listing
G46
Polarity
Mid-polar
Column inner diameter
0.32 mm
Film thickness
0.5 µm
Column length
60 m
Tmax isotherm
280 °C
Tmax temp. program
300 °C
Housing type
Wall coated open tubular (WCOT) capillary column, internal wall of capillary is coated with a very fine film of liquid stationary phase
Hardware
Fused Silica coated with polyimide coiled/wound on metal cage
Cage size
7" (inch)
Integrated precolumn
No
MN726640.30
GC column, Low polar–mid-polar, OPTIMA 1301 MS, 30 m L, 0.25 mm ID, 0.25 µm df
Special offer
Add to Cart
Method
Gas chromatography (GC)
Composition
Silarylene phase with very low bleeding - polarity similar to 6 % cyanopropylphenyl – 94 % dimethylpolysiloxane
Recommended application(s)
All-round phase for environmental analyses, EPA methods, Gas chromatography, GC, PAH, PCBs, Pesticides
Storage temperature
RT
Hazardous material
No
Scope of delivery
1x GC column coiled/wound on metal cage, user manual, certificate of analysis
Type
GC column
Brand
OPTIMA
Phase
OPTIMA 1301 MS
USP listing
G43
Polarity
Low polar–mid-polar
Column inner diameter
0.25 mm
Film thickness
0.25 µm
Column length
30 m
Tmax isotherm
300 °C
Tmax temp. program
320 °C
Housing type
Wall coated open tubular (WCOT) capillary column, internal wall of capillary is coated with a very fine film of liquid stationary phase
Hardware
Fused Silica coated with polyimide coiled/wound on metal cage
Cage size
7" (inch)
Integrated precolumn
No