MN725802.30
GC column, Nonpolar, OPTIMA 1 MS Accent, 30 m L, 0.32 mm ID, 0.25 µm df
Special offer
Add to Cart
Method
Gas chromatography (GC)
Composition
100 % Dimethylpolysiloxane with ultra-low bleeding
Recommended application(s)
All-round phase for environmental analyses, EPA methods, Food and drug analyses, Gas chromatography, GC, PCB, Pesticides, Trace analyses
Storage temperature
RT
Hazardous material
No
Scope of delivery
1x GC column coiled/wound on metal cage, user manual, certificate of analysis
Type
GC column
Brand
OPTIMA
Phase
OPTIMA 1 MS Accent
USP listing
G1, G2, G38
Polarity
Nonpolar
Column inner diameter
0.32 mm
Film thickness
0.25 µm
Column length
30 m
Tmax isotherm
340 °C
Tmax temp. program
360 °C
Housing type
Wall coated open tubular (WCOT) capillary column, internal wall of capillary is coated with a very fine film of liquid stationary phase
Hardware
Fused Silica coated with polyimide coiled/wound on metal cage
Cage size
7" (inch)
Integrated precolumn
No
MN725807.30
GC column, Nonpolar, OPTIMA 1 MS Accent, 30 m L, 0.32 mm ID, 0.5 µm df
Special offer
Add to Cart
Method
Gas chromatography (GC)
Composition
100 % Dimethylpolysiloxane with ultra-low bleeding
Recommended application(s)
All-round phase for environmental analyses, EPA methods, Food and drug analyses, Gas chromatography, GC, PCB, Pesticides, Trace analyses
Storage temperature
RT
Hazardous material
No
Scope of delivery
1x GC column coiled/wound on metal cage, user manual, certificate of analysis
Type
GC column
Brand
OPTIMA
Phase
OPTIMA 1 MS Accent
USP listing
G1, G2, G38
Polarity
Nonpolar
Column inner diameter
0.32 mm
Film thickness
0.5 µm
Column length
30 m
Tmax isotherm
340 °C
Tmax temp. program
360 °C
Housing type
Wall coated open tubular (WCOT) capillary column, internal wall of capillary is coated with a very fine film of liquid stationary phase
Hardware
Fused Silica coated with polyimide coiled/wound on metal cage
Cage size
7" (inch)
Integrated precolumn
No
MN725801.50
GC column, Nonpolar, OPTIMA 1 MS Accent, 50 m L, 0.20 mm ID, 0.2 µm df
Special offer
Add to Cart
Method
Gas chromatography (GC)
Composition
100 % Dimethylpolysiloxane with ultra-low bleeding
Recommended application(s)
All-round phase for environmental analyses, EPA methods, Food and drug analyses, Gas chromatography, GC, PCB, Pesticides, Trace analyses
Storage temperature
RT
Hazardous material
No
Scope of delivery
1x GC column coiled/wound on metal cage, user manual, certificate of analysis
Type
GC column
Brand
OPTIMA
Phase
OPTIMA 1 MS Accent
USP listing
G1, G2, G38
Polarity
Nonpolar
Column inner diameter
0.20 mm
Film thickness
0.2 µm
Column length
50 m
Tmax isotherm
340 °C
Tmax temp. program
360 °C
Housing type
Wall coated open tubular (WCOT) capillary column, internal wall of capillary is coated with a very fine film of liquid stationary phase
Hardware
Fused Silica coated with polyimide coiled/wound on metal cage
Cage size
7" (inch)
Integrated precolumn
No
MN725805.60
GC column, Nonpolar, OPTIMA 1 MS Accent, 60 m L, 0.25 mm ID, 0.25 µm df
Special offer
Add to Cart
Method
Gas chromatography (GC)
Composition
100 % Dimethylpolysiloxane with ultra-low bleeding
Recommended application(s)
All-round phase for environmental analyses, EPA methods, Food and drug analyses, Gas chromatography, GC, PCB, Pesticides, Trace analyses
Storage temperature
RT
Hazardous material
No
Scope of delivery
1x GC column coiled/wound on metal cage, user manual, certificate of analysis
Type
GC column
Brand
OPTIMA
Phase
OPTIMA 1 MS Accent
USP listing
G1, G2, G38
Polarity
Nonpolar
Column inner diameter
0.25 mm
Film thickness
0.25 µm
Column length
60 m
Tmax isotherm
340 °C
Tmax temp. program
360 °C
Housing type
Wall coated open tubular (WCOT) capillary column, internal wall of capillary is coated with a very fine film of liquid stationary phase
Hardware
Fused Silica coated with polyimide coiled/wound on metal cage
Cage size
7" (inch)
Integrated precolumn
No
MN725806.60
GC column, Nonpolar, OPTIMA 1 MS Accent, 60 m L, 0.25 mm ID, 0.5 µm df
Special offer
Add to Cart
Method
Gas chromatography (GC)
Composition
100 % Dimethylpolysiloxane with ultra-low bleeding
Recommended application(s)
All-round phase for environmental analyses, EPA methods, Food and drug analyses, Gas chromatography, GC, PCB, Pesticides, Trace analyses
Storage temperature
RT
Hazardous material
No
Scope of delivery
1x GC column coiled/wound on metal cage, user manual, certificate of analysis
Type
GC column
Brand
OPTIMA
Phase
OPTIMA 1 MS Accent
USP listing
G1, G2, G38
Polarity
Nonpolar
Column inner diameter
0.25 mm
Film thickness
0.5 µm
Column length
60 m
Tmax isotherm
340 °C
Tmax temp. program
360 °C
Housing type
Wall coated open tubular (WCOT) capillary column, internal wall of capillary is coated with a very fine film of liquid stationary phase
Hardware
Fused Silica coated with polyimide coiled/wound on metal cage
Cage size
7" (inch)
Integrated precolumn
No
MN725802.60
GC column, Nonpolar, OPTIMA 1 MS Accent, 60 m L, 0.32 mm ID, 0.25 µm df
Special offer
Add to Cart
Method
Gas chromatography (GC)
Composition
100 % Dimethylpolysiloxane with ultra-low bleeding
Recommended application(s)
All-round phase for environmental analyses, EPA methods, Food and drug analyses, Gas chromatography, GC, PCB, Pesticides, Trace analyses
Storage temperature
RT
Hazardous material
No
Scope of delivery
1x GC column coiled/wound on metal cage, user manual, certificate of analysis
Type
GC column
Brand
OPTIMA
Phase
OPTIMA 1 MS Accent
USP listing
G1, G2, G38
Polarity
Nonpolar
Column inner diameter
0.32 mm
Film thickness
0.25 µm
Column length
60 m
Tmax isotherm
340 °C
Tmax temp. program
360 °C
Housing type
Wall coated open tubular (WCOT) capillary column, internal wall of capillary is coated with a very fine film of liquid stationary phase
Hardware
Fused Silica coated with polyimide coiled/wound on metal cage
Cage size
7" (inch)
Integrated precolumn
No
MN725807.60
GC column, Nonpolar, OPTIMA 1 MS Accent, 60 m L, 0.32 mm ID, 0.5 µm df
Special offer
Add to Cart
Method
Gas chromatography (GC)
Composition
100 % Dimethylpolysiloxane with ultra-low bleeding
Recommended application(s)
All-round phase for environmental analyses, EPA methods, Food and drug analyses, Gas chromatography, GC, PCB, Pesticides, Trace analyses
Storage temperature
RT
Hazardous material
No
Scope of delivery
1x GC column coiled/wound on metal cage, user manual, certificate of analysis
Type
GC column
Brand
OPTIMA
Phase
OPTIMA 1 MS Accent
USP listing
G1, G2, G38
Polarity
Nonpolar
Column inner diameter
0.32 mm
Film thickness
0.5 µm
Column length
60 m
Tmax isotherm
340 °C
Tmax temp. program
360 °C
Housing type
Wall coated open tubular (WCOT) capillary column, internal wall of capillary is coated with a very fine film of liquid stationary phase
Hardware
Fused Silica coated with polyimide coiled/wound on metal cage
Cage size
7" (inch)
Integrated precolumn
No
MN726203.12
GC column, Nonpolar, OPTIMA 1 MS, 12 m L, 0.20 mm ID, 0.35 µm df
Special offer
Add to Cart
Method
Gas chromatography (GC)
Composition
100 % Dimethylpolysiloxane with low bleeding
Recommended application(s)
All-round phase for environmental analyses, EPA methods, Food and drug analyses, Gas chromatography, GC, PCB, Pesticides, Trace analyses
Storage temperature
RT
Hazardous material
No
Scope of delivery
1x GC column coiled/wound on metal cage, user manual, certificate of analysis
Type
GC column
Brand
OPTIMA
Phase
OPTIMA 1 MS
USP listing
G1, G2, G38
Polarity
Nonpolar
Column inner diameter
0.20 mm
Film thickness
0.35 µm
Column length
12 m
Tmax isotherm
340 °C
Tmax temp. program
360 °C
Housing type
Wall coated open tubular (WCOT) capillary column, internal wall of capillary is coated with a very fine film of liquid stationary phase
Hardware
Fused Silica coated with polyimide coiled/wound on metal cage
Cage size
7" (inch)
Integrated precolumn
No
MN726205.15
GC column, Nonpolar, OPTIMA 1 MS, 15 m L, 0.25 mm ID, 0.25 µm df
Special offer
Add to Cart
Method
Gas chromatography (GC)
Composition
100 % Dimethylpolysiloxane with low bleeding
Recommended application(s)
All-round phase for environmental analyses, EPA methods, Food and drug analyses, Gas chromatography, GC, PCB, Pesticides, Trace analyses
Storage temperature
RT
Hazardous material
No
Scope of delivery
1x GC column coiled/wound on metal cage, user manual, certificate of analysis
Type
GC column
Brand
OPTIMA
Phase
OPTIMA 1 MS
USP listing
G1, G2, G38
Polarity
Nonpolar
Column inner diameter
0.25 mm
Film thickness
0.25 µm
Column length
15 m
Tmax isotherm
340 °C
Tmax temp. program
360 °C
Housing type
Wall coated open tubular (WCOT) capillary column, internal wall of capillary is coated with a very fine film of liquid stationary phase
Hardware
Fused Silica coated with polyimide coiled/wound on metal cage
Cage size
7" (inch)
Integrated precolumn
No
MN726201.25
GC column, Nonpolar, OPTIMA 1 MS, 25 m L, 0.20 mm ID, 0.2 µm df
Special offer
Add to Cart
Method
Gas chromatography (GC)
Composition
100 % Dimethylpolysiloxane with low bleeding
Recommended application(s)
All-round phase for environmental analyses, EPA methods, Food and drug analyses, Gas chromatography, GC, PCB, Pesticides, Trace analyses
Storage temperature
RT
Hazardous material
No
Scope of delivery
1x GC column coiled/wound on metal cage, user manual, certificate of analysis
Type
GC column
Brand
OPTIMA
Phase
OPTIMA 1 MS
USP listing
G1, G2, G38
Polarity
Nonpolar
Column inner diameter
0.20 mm
Film thickness
0.2 µm
Column length
25 m
Tmax isotherm
340 °C
Tmax temp. program
360 °C
Housing type
Wall coated open tubular (WCOT) capillary column, internal wall of capillary is coated with a very fine film of liquid stationary phase
Hardware
Fused Silica coated with polyimide coiled/wound on metal cage
Cage size
7" (inch)
Integrated precolumn