MN726442.60
GC column, Low polar–mid-polar, OPTIMA DELTA-3, 60 m L, 0.32 mm ID, 1 µm df
Special offer
Add to Cart
Method
Gas chromatography (GC)
Composition
Proprietary derivatized phenyl groups on a polysiloxane backbone
Recommended application(s)
Azo dyes, Cannabinoids, FAMEs, Gas chromatography, GC, Parlar compounds (Toxaphene Congeners), Pesticides, Phenols, Solvents
Storage temperature
RT
Hazardous material
No
Scope of delivery
1x GC column coiled/wound on metal cage, user manual, certificate of analysis
Type
GC column
Brand
OPTIMA
Phase
OPTIMA DELTA-3
USP listing
G49
Polarity
Low polar–mid-polar
Column inner diameter
0.32 mm
Film thickness
1 µm
Column length
60 m
Tmax isotherm
340 °C
Tmax temp. program
360 °C
Housing type
Wall coated open tubular (WCOT) capillary column, internal wall of capillary is coated with a very fine film of liquid stationary phase
Hardware
Fused Silica coated with polyimide coiled/wound on metal cage
Cage size
7" (inch)
Integrated precolumn
No
MN726102.15
GC column, Nonpolar–low polar, OPTIMA 5 HT, 15 m L, 0.25 mm ID, 0.1 µm df
Special offer
Add to Cart
Method
Gas chromatography (GC)
Composition
Cross-linked silarylene phase - polarity similar to 5 % phenyl – 95 % methylpolysiloxane, 5 % diphenyl – 95 % dimethylpolysiloxane
Recommended application(s)
Fuel, Gas chromatography, GC, High boiling analytes, Hydrocarbons, Oils, Simulated distillation
Storage temperature
RT
Hazardous material
No
Scope of delivery
1x GC column coiled/wound on metal cage, user manual, certificate of analysis
Type
GC column
Brand
OPTIMA
Phase
OPTIMA 5 HT
USP listing
G27, G36
Polarity
Nonpolar–low polar
Column inner diameter
0.25 mm
Film thickness
0.1 µm
Column length
15 m
Tmax isotherm
380 °C
Tmax temp. program
400 °C
Housing type
Wall coated open tubular (WCOT) capillary column, internal wall of capillary is coated with a very fine film of liquid stationary phase
Hardware
Fused Silica coated with polyimide coiled/wound on metal cage
Cage size
7" (inch)
Integrated precolumn
No
MN726106.15
GC column, Nonpolar–low polar, OPTIMA 5 HT, 15 m L, 0.25 mm ID, 0.25 µm df
Special offer
Add to Cart
Method
Gas chromatography (GC)
Composition
Cross-linked silarylene phase - polarity similar to 5 % phenyl – 95 % methylpolysiloxane, 5 % diphenyl – 95 % dimethylpolysiloxane
Recommended application(s)
Fuel, Gas chromatography, GC, High boiling analytes, Hydrocarbons, Oils, Simulated distillation
Storage temperature
RT
Hazardous material
No
Scope of delivery
1x GC column coiled/wound on metal cage, user manual, certificate of analysis
Type
GC column
Brand
OPTIMA
Phase
OPTIMA 5 HT
USP listing
G27, G36
Polarity
Nonpolar–low polar
Column inner diameter
0.25 mm
Film thickness
0.25 µm
Column length
15 m
Tmax isotherm
380 °C
Tmax temp. program
400 °C
Housing type
Wall coated open tubular (WCOT) capillary column, internal wall of capillary is coated with a very fine film of liquid stationary phase
Hardware
Fused Silica coated with polyimide coiled/wound on metal cage
Cage size
7" (inch)
Integrated precolumn
No
MN726104.15
GC column, Nonpolar–low polar, OPTIMA 5 HT, 15 m L, 0.32 mm ID, 0.1 µm df
Special offer
Add to Cart
Method
Gas chromatography (GC)
Composition
Cross-linked silarylene phase - polarity similar to 5 % phenyl – 95 % methylpolysiloxane, 5 % diphenyl – 95 % dimethylpolysiloxane
Recommended application(s)
Fuel, Gas chromatography, GC, High boiling analytes, Hydrocarbons, Oils, Simulated distillation
Storage temperature
RT
Hazardous material
No
Scope of delivery
1x GC column coiled/wound on metal cage, user manual, certificate of analysis
Type
GC column
Brand
OPTIMA
Phase
OPTIMA 5 HT
USP listing
G27, G36
Polarity
Nonpolar–low polar
Column inner diameter
0.32 mm
Film thickness
0.1 µm
Column length
15 m
Tmax isotherm
380 °C
Tmax temp. program
400 °C
Housing type
Wall coated open tubular (WCOT) capillary column, internal wall of capillary is coated with a very fine film of liquid stationary phase
Hardware
Fused Silica coated with polyimide coiled/wound on metal cage
Cage size
7" (inch)
Integrated precolumn
No
MN726108.15
GC column, Nonpolar–low polar, OPTIMA 5 HT, 15 m L, 0.32 mm ID, 0.25 µm df
Special offer
Add to Cart
Method
Gas chromatography (GC)
Composition
Cross-linked silarylene phase - polarity similar to 5 % phenyl – 95 % methylpolysiloxane, 5 % diphenyl – 95 % dimethylpolysiloxane
Recommended application(s)
Fuel, Gas chromatography, GC, High boiling analytes, Hydrocarbons, Oils, Simulated distillation
Storage temperature
RT
Hazardous material
No
Scope of delivery
1x GC column coiled/wound on metal cage, user manual, certificate of analysis
Type
GC column
Brand
OPTIMA
Phase
OPTIMA 5 HT
USP listing
G27, G36
Polarity
Nonpolar–low polar
Column inner diameter
0.32 mm
Film thickness
0.25 µm
Column length
15 m
Tmax isotherm
380 °C
Tmax temp. program
400 °C
Housing type
Wall coated open tubular (WCOT) capillary column, internal wall of capillary is coated with a very fine film of liquid stationary phase
Hardware
Fused Silica coated with polyimide coiled/wound on metal cage
Cage size
7" (inch)
Integrated precolumn
No
MN726102.30
GC column, Nonpolar–low polar, OPTIMA 5 HT, 30 m L, 0.25 mm ID, 0.1 µm df
Special offer
Add to Cart
Method
Gas chromatography (GC)
Composition
Cross-linked silarylene phase - polarity similar to 5 % phenyl – 95 % methylpolysiloxane, 5 % diphenyl – 95 % dimethylpolysiloxane
Recommended application(s)
Fuel, Gas chromatography, GC, High boiling analytes, Hydrocarbons, Oils, Simulated distillation
Storage temperature
RT
Hazardous material
No
Scope of delivery
1x GC column coiled/wound on metal cage, user manual, certificate of analysis
Type
GC column
Brand
OPTIMA
Phase
OPTIMA 5 HT
USP listing
G27, G36
Polarity
Nonpolar–low polar
Column inner diameter
0.25 mm
Film thickness
0.1 µm
Column length
30 m
Tmax isotherm
380 °C
Tmax temp. program
400 °C
Housing type
Wall coated open tubular (WCOT) capillary column, internal wall of capillary is coated with a very fine film of liquid stationary phase
Hardware
Fused Silica coated with polyimide coiled/wound on metal cage
Cage size
7" (inch)
Integrated precolumn
No
MN726106.30
GC column, Nonpolar–low polar, OPTIMA 5 HT, 30 m L, 0.25 mm ID, 0.25 µm df
Special offer
Add to Cart
Method
Gas chromatography (GC)
Composition
Cross-linked silarylene phase - polarity similar to 5 % phenyl – 95 % methylpolysiloxane, 5 % diphenyl – 95 % dimethylpolysiloxane
Recommended application(s)
Fuel, Gas chromatography, GC, High boiling analytes, Hydrocarbons, Oils, Simulated distillation
Storage temperature
RT
Hazardous material
No
Scope of delivery
1x GC column coiled/wound on metal cage, user manual, certificate of analysis
Type
GC column
Brand
OPTIMA
Phase
OPTIMA 5 HT
USP listing
G27, G36
Polarity
Nonpolar–low polar
Column inner diameter
0.25 mm
Film thickness
0.25 µm
Column length
30 m
Tmax isotherm
380 °C
Tmax temp. program
400 °C
Housing type
Wall coated open tubular (WCOT) capillary column, internal wall of capillary is coated with a very fine film of liquid stationary phase
Hardware
Fused Silica coated with polyimide coiled/wound on metal cage
Cage size
7" (inch)
Integrated precolumn
No
MN726104.30
GC column, Nonpolar–low polar, OPTIMA 5 HT, 30 m L, 0.32 mm ID, 0.1 µm df
Special offer
Add to Cart
Method
Gas chromatography (GC)
Composition
Cross-linked silarylene phase - polarity similar to 5 % phenyl – 95 % methylpolysiloxane, 5 % diphenyl – 95 % dimethylpolysiloxane
Recommended application(s)
Fuel, Gas chromatography, GC, High boiling analytes, Hydrocarbons, Oils, Simulated distillation
Storage temperature
RT
Hazardous material
No
Scope of delivery
1x GC column coiled/wound on metal cage, user manual, certificate of analysis
Type
GC column
Brand
OPTIMA
Phase
OPTIMA 5 HT
USP listing
G27, G36
Polarity
Nonpolar–low polar
Column inner diameter
0.32 mm
Film thickness
0.1 µm
Column length
30 m
Tmax isotherm
380 °C
Tmax temp. program
400 °C
Housing type
Wall coated open tubular (WCOT) capillary column, internal wall of capillary is coated with a very fine film of liquid stationary phase
Hardware
Fused Silica coated with polyimide coiled/wound on metal cage
Cage size
7" (inch)
Integrated precolumn
No
MN726108.30
GC column, Nonpolar–low polar, OPTIMA 5 HT, 30 m L, 0.32 mm ID, 0.25 µm df
Special offer
Add to Cart
Method
Gas chromatography (GC)
Composition
Cross-linked silarylene phase - polarity similar to 5 % phenyl – 95 % methylpolysiloxane, 5 % diphenyl – 95 % dimethylpolysiloxane
Recommended application(s)
Fuel, Gas chromatography, GC, High boiling analytes, Hydrocarbons, Oils, Simulated distillation
Storage temperature
RT
Hazardous material
No
Scope of delivery
1x GC column coiled/wound on metal cage, user manual, certificate of analysis
Type
GC column
Brand
OPTIMA
Phase
OPTIMA 5 HT
USP listing
G27, G36
Polarity
Nonpolar–low polar
Column inner diameter
0.32 mm
Film thickness
0.25 µm
Column length
30 m
Tmax isotherm
380 °C
Tmax temp. program
400 °C
Housing type
Wall coated open tubular (WCOT) capillary column, internal wall of capillary is coated with a very fine film of liquid stationary phase
Hardware
Fused Silica coated with polyimide coiled/wound on metal cage
Cage size
7" (inch)
Integrated precolumn
No
MN726162.30
GC column, Mid-polar, OPTIMA 17 MS, 30 m L, 0.25 mm ID, 0.25 µm df
Special offer
Add to Cart
Method
Gas chromatography (GC)
Composition
Silarylene phase with very low bleeding - polarity similar to 50 % diphenyl – 50 % dimethylpolysiloxane
Recommended application(s)
Cypermethrin, Drugs of abuse, Gas chromatography, GC, Pesticides, Phthalates, Steroids
Storage temperature
RT
Hazardous material
No
Scope of delivery
1x GC column coiled/wound on metal cage, user manual, certificate of analysis
Type
GC column
Brand
OPTIMA
Phase
OPTIMA 17 MS
USP listing
G3
Polarity
Mid-polar
Column inner diameter
0.25 mm
Film thickness
0.25 µm
Column length
30 m
Tmax isotherm
340 °C
Tmax temp. program
360 °C
Housing type
Wall coated open tubular (WCOT) capillary column, internal wall of capillary is coated with a very fine film of liquid stationary phase
Hardware
Fused Silica coated with polyimide coiled/wound on metal cage
Cage size
7" (inch)
Integrated precolumn
No