MN760325.30
EC HPLC column (analytical), NUCLEODUR C18 HTec, 3 µm, 150x3 mm
Special offer
Add to Cart
Recommended application(s)
Aldehydes, Applications at pH extremes (1-11), Basic, neutral and acidic pharmaceuticals, Derivatized amino acids, Fat-soluble vitamins, High loading capacity, Ketones, Pesticides, Phenolic compounds, Reversed phase, RP applications HPLC, Suitable for LC-MS
Storage temperature
RT
Scope of delivery
1x analytical HPLC column, instruction leaflet, certificate of analysis
Hazardous material
No
Method
HPLC, analytical
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR C18 HTec
USP listing
L1
Surface chemistry
High density octadecyl (C18, ODS) modification, base deactivated (BDS)
Mode
Reversed phase (RP)
Type
EC HPLC column (analytical)
Hardware
Stainless steel
Column length
150 mm
Column inner diameter
3 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
3 µm
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
18.0 %
pH stability
1.0–11.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
600 bar
Column volume
1.05 mL
MN760325.40
EC HPLC column (analytical), NUCLEODUR C18 HTec, 3 µm, 150x4 mm
Special offer
Add to Cart
Recommended application(s)
Aldehydes, Applications at pH extremes (1-11), Basic, neutral and acidic pharmaceuticals, Derivatized amino acids, Fat-soluble vitamins, High loading capacity, Ketones, Pesticides, Phenolic compounds, Reversed phase, RP applications HPLC, Suitable for LC-MS
Storage temperature
RT
Scope of delivery
1x analytical HPLC column, instruction leaflet, certificate of analysis
Hazardous material
No
Method
HPLC, analytical
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR C18 HTec
USP listing
L1
Surface chemistry
High density octadecyl (C18, ODS) modification, base deactivated (BDS)
Mode
Reversed phase (RP)
Type
EC HPLC column (analytical)
Hardware
Stainless steel
Column length
150 mm
Column inner diameter
4 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
3 µm
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
18.0 %
pH stability
1.0–11.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
600 bar
Column volume
1.9 mL
MN760325.46
EC HPLC column (analytical), NUCLEODUR C18 HTec, 3 µm, 150x4.6 mm
Special offer
Add to Cart
Recommended application(s)
Aldehydes, Applications at pH extremes (1-11), Basic, neutral and acidic pharmaceuticals, Derivatized amino acids, Fat-soluble vitamins, High loading capacity, Ketones, Pesticides, Phenolic compounds, Reversed phase, RP applications HPLC, Suitable for LC-MS
Storage temperature
RT
Scope of delivery
1x analytical HPLC column, instruction leaflet, certificate of analysis
Hazardous material
No
Method
HPLC, analytical
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR C18 HTec
USP listing
L1
Surface chemistry
High density octadecyl (C18, ODS) modification, base deactivated (BDS)
Mode
Reversed phase (RP)
Type
EC HPLC column (analytical)
Hardware
Stainless steel
Column length
150 mm
Column inner diameter
4.6 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
3 µm
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
18.0 %
pH stability
1.0–11.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
600 bar
Column volume
2.5 mL
MN760326.20
EC HPLC column (analytical), NUCLEODUR C18 HTec, 3 µm, 250x2 mm
Special offer
Add to Cart
Recommended application(s)
Aldehydes, Applications at pH extremes (1-11), Basic, neutral and acidic pharmaceuticals, Derivatized amino acids, Fat-soluble vitamins, High loading capacity, Ketones, Pesticides, Phenolic compounds, Reversed phase, RP applications HPLC, Suitable for LC-MS
Storage temperature
RT
Scope of delivery
1x analytical HPLC column, instruction leaflet, certificate of analysis
Hazardous material
No
Method
HPLC, analytical
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR C18 HTec
USP listing
L1
Surface chemistry
High density octadecyl (C18, ODS) modification, base deactivated (BDS)
Mode
Reversed phase (RP)
Type
EC HPLC column (analytical)
Hardware
Stainless steel
Column length
250 mm
Column inner diameter
2 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
3 µm
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
18.0 %
pH stability
1.0–11.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
600 bar
Column volume
0.8 mL
MN760326.30
EC HPLC column (analytical), NUCLEODUR C18 HTec, 3 µm, 250x3 mm
Special offer
Add to Cart
Recommended application(s)
Aldehydes, Applications at pH extremes (1-11), Basic, neutral and acidic pharmaceuticals, Derivatized amino acids, Fat-soluble vitamins, High loading capacity, Ketones, Pesticides, Phenolic compounds, Reversed phase, RP applications HPLC, Suitable for LC-MS
Storage temperature
RT
Scope of delivery
1x analytical HPLC column, instruction leaflet, certificate of analysis
Hazardous material
No
Method
HPLC, analytical
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR C18 HTec
USP listing
L1
Surface chemistry
High density octadecyl (C18, ODS) modification, base deactivated (BDS)
Mode
Reversed phase (RP)
Type
EC HPLC column (analytical)
Hardware
Stainless steel
Column length
250 mm
Column inner diameter
3 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
3 µm
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
18.0 %
pH stability
1.0–11.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
600 bar
Column volume
1.75 mL
MN760326.40
EC HPLC column (analytical), NUCLEODUR C18 HTec, 3 µm, 250x4 mm
Special offer
Add to Cart
Recommended application(s)
Aldehydes, Applications at pH extremes (1-11), Basic, neutral and acidic pharmaceuticals, Derivatized amino acids, Fat-soluble vitamins, High loading capacity, Ketones, Pesticides, Phenolic compounds, Reversed phase, RP applications HPLC, Suitable for LC-MS
Storage temperature
RT
Scope of delivery
1x analytical HPLC column, instruction leaflet, certificate of analysis
Hazardous material
No
Method
HPLC, analytical
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR C18 HTec
USP listing
L1
Surface chemistry
High density octadecyl (C18, ODS) modification, base deactivated (BDS)
Mode
Reversed phase (RP)
Type
EC HPLC column (analytical)
Hardware
Stainless steel
Column length
250 mm
Column inner diameter
4 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
3 µm
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
18.0 %
pH stability
1.0–11.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
600 bar
Column volume
3.15 mL
MN760326.46
EC HPLC column (analytical), NUCLEODUR C18 HTec, 3 µm, 250x4.6 mm
Special offer
Add to Cart
Recommended application(s)
Aldehydes, Applications at pH extremes (1-11), Basic, neutral and acidic pharmaceuticals, Derivatized amino acids, Fat-soluble vitamins, High loading capacity, Ketones, Pesticides, Phenolic compounds, Reversed phase, RP applications HPLC, Suitable for LC-MS
Storage temperature
RT
Scope of delivery
1x analytical HPLC column, instruction leaflet, certificate of analysis
Hazardous material
No
Method
HPLC, analytical
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR C18 HTec
USP listing
L1
Surface chemistry
High density octadecyl (C18, ODS) modification, base deactivated (BDS)
Mode
Reversed phase (RP)
Type
EC HPLC column (analytical)
Hardware
Stainless steel
Column length
250 mm
Column inner diameter
4.6 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
3 µm
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
18.0 %
pH stability
1.0–11.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
600 bar
Column volume
4.15 mL
MN762551.100
VP HPLC column (preparative), NUCLEODUR C18 HTec, 5 µm, 50x10 mm
Special offer
Add to Cart
Recommended application(s)
For examples please see analytical NUCLEODUR Sphinx RP, RP applications (preparative)
Storage temperature
RT
Scope of delivery
1x preparative HPLC column, instruction leaflet, certificate of analysis
Hazardous material
No
Method
HPLC, preparative
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR C18 HTec
USP listing
L1
Surface chemistry
High density octadecyl (C18, ODS) modification, base deactivated (BDS)
Mode
Reversed phase (RP)
Type
VP HPLC column (preparative)
Hardware
Stainless steel
Column length
50 mm
Column inner diameter
10 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
5 µm
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
18.0 %
pH stability
1.0–10.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
400 bar
Column volume
3.9 mL
MN762551.210
VP HPLC column (preparative), NUCLEODUR C18 HTec, 5 µm, 50x21 mm
Special offer
Add to Cart
Recommended application(s)
For examples please see analytical NUCLEODUR Sphinx RP, RP applications (preparative)
Storage temperature
RT
Scope of delivery
1x preparative HPLC column, instruction leaflet, certificate of analysis
Hazardous material
No
Method
HPLC, preparative
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR C18 HTec
USP listing
L1
Surface chemistry
High density octadecyl (C18, ODS) modification, base deactivated (BDS)
Mode
Reversed phase (RP)
Type
VP HPLC column (preparative)
Hardware
Stainless steel
Column length
50 mm
Column inner diameter
21 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
5 µm
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
18.0 %
pH stability
1.0–10.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
400 bar
Column volume
17 mL
MN762553.210
VP HPLC column (preparative), NUCLEODUR C18 HTec, 5 µm, 100x21 mm
Special offer
Add to Cart
Recommended application(s)
For examples please see analytical NUCLEODUR Sphinx RP, RP applications (preparative)
Storage temperature
RT
Scope of delivery
1x preparative HPLC column, instruction leaflet, certificate of analysis
Hazardous material
No
Method
HPLC, preparative
Brand
NUCLEODUR
Base material
NUCLEODUR - high purity silica
Phase
NUCLEODUR C18 HTec
USP listing
L1
Surface chemistry
High density octadecyl (C18, ODS) modification, base deactivated (BDS)
Mode
Reversed phase (RP)
Type
VP HPLC column (preparative)
Hardware
Stainless steel
Column length
100 mm
Column inner diameter
21 mm
Particle type
Fully porous particles (FPP)
Particle shape
Spherical
Particle size
5 µm
Eluent in HPLC column
Acetonitrile – water
Endcapped
Yes
Carbon content
18.0 %
pH stability
1.0–10.0
Pore size
110 Å
Specific surface according to BET
340 m²/g
Temperature stability (max)
60 °C
Pressure stability (max)
400 bar
Column volume
35 mL