+852-3069 6950
css@gugent.com.hk
 

GL Sciences columns provide excellent separation and resolution of target compounds featuring new high-purity evolved surface silica. GL Sciences columns silica base is uniquely modified to provide maximum column performance including low operating back-pressure, high inertness, high efficiency and wide solvent compatibility. Get the appropriate column from a large selection of column configurations and formats compatible with many HPLC methods including analytical, preparative, capillary HPLC and UHPLC. 

Catalog No. Product Net Price
GLS5020-10121 MonoCap C18 Fast-flow Capillary Column, 0.2 mm I.D. x 150 mm, Metal 1127 
Add to Cart
  • Column or Guard
  • Column
  • Column format
  • Capillary
  • Phase
  • MonoCap C18 Fast-flow
  • Functional group
  • Octadecyl
  • Length
  • 150 mm
  • Inner diameter
  • 0.2 mm
  • Pore size
  • 2 µm
  • End capping
  • Yes
  • Unit size
  • 1 pc.
  • Max Operating Pressure
  • 22 MPa (220 bar)
  • Material
  • Metal
  • Skeleton
  • 1 µm
  • Through-pore Size
  • 2 µm
  • Mesopore Size
  • 15 nm
GLS5020-10122 MonoCap C18 Fast-flow Capillary Column, 0.2 mm I.D. x 50 mm, Metal 1162 
Add to Cart
  • Column or Guard
  • Column
  • Column format
  • Capillary
  • Phase
  • MonoCap C18 Fast-flow
  • Functional group
  • Octadecyl
  • Length
  • 50 mm
  • Inner diameter
  • 0.2 mm
  • Pore size
  • 2 µm
  • End capping
  • Yes
  • Unit size
  • 1 pc.
  • Max Operating Pressure
  • 22 MPa (220 bar)
  • Material
  • Metal
  • Skeleton
  • 1 µm
  • Through-pore Size
  • 2 µm
  • Mesopore Size
  • 15 nm
GLS5020-10124 MonoCap C18 Fast-flow Capillary Column, 0.2 mm I.D. x 100 mm, Metal 868 
Add to Cart
  • Column or Guard
  • Column
  • Column format
  • Capillary
  • Phase
  • MonoCap C18 Fast-flow
  • Functional group
  • Octadecyl
  • Length
  • 100 mm
  • Inner diameter
  • 0.2 mm
  • Pore size
  • 2 µm
  • End capping
  • Yes
  • Unit size
  • 1 pc.
  • Max Operating Pressure
  • 22 MPa (220 bar)
  • Material
  • Metal
  • Skeleton
  • 1 µm
  • Through-pore Size
  • 2 µm
  • Mesopore Size
  • 15 nm
GLS5020-10141 MonoCap C18 Nano-flow Capillary Column, 0.05 mm I.D. x 150 mm, Metal 1232 
Add to Cart
  • Column or Guard
  • Column
  • Column format
  • Capillary
  • Phase
  • MonoCap C18 Nano-Flow
  • Functional group
  • Octadecyl
  • Length
  • 150 mm
  • Inner diameter
  • 0.05 mm
  • Pore size
  • 1 µm
  • End capping
  • Yes
  • Unit size
  • 1 pc.
  • Max Operating Pressure
  • 22 MPa (220 bar)
  • Material
  • Metal
  • Skeleton
  • 1 µm
  • Through-pore Size
  • 1 µm
  • Mesopore Size
  • 11 nm
GLS5020-10143 MonoCap C18 Nano-flow Capillary Column, 0.05 mm I.D. x 50 mm, Metal 931 
Add to Cart
  • Column or Guard
  • Column
  • Column format
  • Capillary
  • Phase
  • MonoCap C18 Nano-Flow
  • Functional group
  • Octadecyl
  • Length
  • 50 mm
  • Inner diameter
  • 0.05 mm
  • Pore size
  • 1 µm
  • End capping
  • Yes
  • Unit size
  • 1 pc.
  • Max Operating Pressure
  • 22 MPa (220 bar)
  • Material
  • Metal
  • Skeleton
  • 1 µm
  • Through-pore Size
  • 1 µm
  • Mesopore Size
  • 11 nm
GLS5020-10151 MonoCap C18 Nano-flow Capillary Column, 0.1 mm I.D. x 150 mm, Metal 1232 
Add to Cart
  • Column or Guard
  • Column
  • Column format
  • Capillary
  • Phase
  • MonoCap C18 Nano-Flow
  • Functional group
  • Octadecyl
  • Length
  • 150 mm
  • Inner diameter
  • 0.1 mm
  • Pore size
  • 1 µm
  • End capping
  • Yes
  • Unit size
  • 1 pc.
  • Max Operating Pressure
  • 22 MPa (220 bar)
  • Material
  • Metal
  • Skeleton
  • 1 µm
  • Through-pore Size
  • 1 µm
  • Mesopore Size
  • 11 nm
GLS5020-10153 MonoCap C18 Nano-flow Capillary Column, 0.1 mm I.D. x 50 mm, Metal 931 
Add to Cart
  • Column or Guard
  • Column
  • Column format
  • Capillary
  • Phase
  • MonoCap C18 Nano-Flow
  • Functional group
  • Octadecyl
  • Length
  • 50 mm
  • Inner diameter
  • 0.1 mm
  • Pore size
  • 1 µm
  • End capping
  • Yes
  • Unit size
  • 1 pc.
  • Max Operating Pressure
  • 22 MPa (220 bar)
  • Material
  • Metal
  • Skeleton
  • 1 µm
  • Through-pore Size
  • 1 µm
  • Mesopore Size
  • 11 nm
GLS5020-10161 MonoCap C18 Nano-flow Capillary Column, 0.2 mm I.D. x 150 mm, Metal 1232 
Add to Cart
  • Column or Guard
  • Column
  • Column format
  • Capillary
  • Phase
  • MonoCap C18 Nano-Flow
  • Functional group
  • Octadecyl
  • Length
  • 150 mm
  • Inner diameter
  • 0.2 mm
  • Pore size
  • 1 µm
  • End capping
  • Yes
  • Unit size
  • 1 pc.
  • Max Operating Pressure
  • 22 MPa (220 bar)
  • Material
  • Metal
  • Skeleton
  • 1 µm
  • Through-pore Size
  • 1 µm
  • Mesopore Size
  • 11 nm
GLS5020-10163 MonoCap C18 Nano-flow Capillary Column, 0.2 mm I.D. x 50 mm, Metal 931 
Add to Cart
  • Column or Guard
  • Column
  • Column format
  • Capillary
  • Phase
  • MonoCap C18 Nano-Flow
  • Functional group
  • Octadecyl
  • Length
  • 50 mm
  • Inner diameter
  • 0.2 mm
  • Pore size
  • 1 µm
  • End capping
  • Yes
  • Unit size
  • 1 pc.
  • Max Operating Pressure
  • 22 MPa (220 bar)
  • Material
  • Metal
  • Skeleton
  • 1 µm
  • Through-pore Size
  • 1 µm
  • Mesopore Size
  • 11 nm
GLS5020-10211 MonoCap C18 Fast-flow Capillary Column, 0.075 mm I.D. x 50 mm, Metal 875 
Add to Cart
  • Column or Guard
  • Column
  • Column format
  • Capillary
  • Phase
  • MonoCap C18 Fast-flow
  • Functional group
  • Octadecyl
  • Length
  • 50 mm
  • Inner diameter
  • 0.075 mm
  • Pore size
  • 2 µm
  • End capping
  • Yes
  • Unit size
  • 1 pc.
  • Max Operating Pressure
  • 22 MPa (220 bar)
  • Material
  • Metal
  • Skeleton
  • 1 µm
  • Through-pore Size
  • 2 µm
  • Mesopore Size
  • 15 nm

Overview

INERTSIL HPLC Columns

GL Sciences in Japan is the manufacturer of well known Inertsil HPLC columns. GL Sciences' Inertsil columns offer everything you need for your critical separations in all phases of drug development, and something less. Inertsil's uniquely modified silicas and meticulously engineered column hardware allow our columns to operate at significantly lower back pressures than competitive columns, without sacrificing efficiency. Inertsil's wide pH compatibility and excellent stability at elevated temperatures make it the ideal choice for your chromatography needs, whether you are using a traditional HPLC system or the latest rapid gradient LC/MS system with precise temperature control.


InertSustain HPLC Columns

Generally, silica based columns are mechanically stable and provide high efficiencies, however, they cannot be used under alkaline conditions and their residual silanol groups tend to adsorb organic bases. InertSustain employs a radically new type of silica, in which the surface of the silica is uniquely modified, enabling precise control of the silica properties. InertSustain inherits the advantages of all the current Inertsil HPLC columns (e.g., extremely low operating back pressure, superior inertness to typically any analytes, high efficiency and compatibility with a wide range of solvents), but now can be used for wide pH analysis with consistent performance from column to column and lot to lot.

The InertSustain Serie has the following columns available; InertSustain C18, InertSustain AQ-C18, InertSustainSwift C18, InertSustainSwift C8, InertSustain Phenyl, InertSustain Phenylhexyl, InertSustain Cyano, InertSustain NH2, InertSustain Amide, InertSustainBio C18.


MonoCap High Resolution

MonoCap C18 HighResolution 2000 is a 2 meter length monolithic silica capillary column which is designed for identifying extremely high number of peptides/proteins for proteome research via LC-MS/MS.

MonoCap HILIC-UP is an important addition to the MonoCap C18 HighResolution 2000 column series. MonoCap HILIC-UP can retain highly hydrophilic peptides/proteins which may lead to discovering new peptides/proteins where a C18 phase couldn’t identify. In HILIC, the higher the organic concentration, the greater the retention of more polar analytes. One of the biggest benefit of HILIC mode is, a high organic solvent concentration of the mobile phase will lead to a high sensitivity LC-MS/MS analysis.