+852-3069 6950
css@gugent.com.hk
 

Columns, cartridges, column packing materials, and accessories for use with ion, gas, and liquid chromatography systems and methods. A wide variety of stationary phases and column dimensions are available to accommodate specialized laboratory procedures.

Catalog No. Product Net Price
THM076029 Dionex™ IonPac™ CS19 IC Column, 8 µm, 2 × 50 mm 749.35 
Add to Cart
  • Max. Pressure
  • 3000 psi (207 bar)
  • Stationary Phase
  • Microporous Resin
  • Column Type
  • Guard Column
  • Phase
  • Microporous Resin
  • Unit Size
  • Each 1
  • Type
  • Guard Column
  • Column Capacity
  • 11 µeq
  • For Use With (Application)
  • Cation Exchange
  • For Use With (Equipment)
  • IonPac CS19 Analytical Column
  • Hydrophobicity
  • Medium
  • Solvent Compatibility
  • Acidic Eluents (pH 0 to 7), 10% HPLC Solvents, Alcohols Should be Avoided
  • Format
  • Microbore
  • Pressure
  • 3000 psi (207 bar)
  • Compatibility
  • Acidic Eluents (pH 0 to 7), 10% HPLC Solvents, Alcohols Should be Avoided
THM076024 Dionex™ IonPac™ CS19 IC Column, 4 µm, 0.4 × 250 mm 2269.21 
Add to Cart
  • Max. Pressure
  • 3000 psi (207 bar)
  • pH
  • 0 to 7
  • Stationary Phase
  • Super Macroporous Resin
  • Packing Material
  • Ethylvinylbenzene/Divinylbenzene
  • Column Type
  • Capillary Separator
  • Phase
  • Super Macroporous Resin
  • Unit Size
  • Each 1
  • Type
  • Capillary Separator
  • Crosslinking
  • 55% DVB
  • Description
  • CS19; 0.4 x 250 mm
  • Column Capacity
  • 24 µeq
  • Column Chemistry
  • Acidic
  • Flow Rate
  • 0.010 to 0.015 mL/min.
  • For Use With (Application)
  • Cation Exchange
  • For Use With (Equipment)
  • RFIC Systems
  • Hydrophobicity
  • Medium
  • Solvent Compatibility
  • Acidic Eluents (pH 0 to 7), 0 to 10% HPLC Solvents, Alcohols Should be Avoided
  • Format
  • Capillary
  • Solvents
  • 0 to 10% HPLC Solvents, Alcohols Should be Avoided
  • Pressure
  • 3000 psi (207 bar)
  • Compatibility
  • Acidic Eluents (pH 0 to 7), 0 to 10% HPLC Solvents, Alcohols Should be Avoided
THM076026 Dionex™ IonPac™ CS19 IC Column, 4 µm, 4 × 250 mm 2269.21 
Add to Cart
  • Max. Pressure
  • 3000 psi (207 bar)
  • pH
  • 0 to 7
  • Stationary Phase
  • Super Macroporous Resin
  • Packing Material
  • Ethylvinylbenzene/Divinylbenzene
  • Column Type
  • Analytical Column
  • Phase
  • Super Macroporous Resin
  • Unit Size
  • Each 1
  • Type
  • Analytical Column
  • Crosslinking
  • 55% DVB
  • Column Capacity
  • 2410 µeq
  • Column Chemistry
  • Acidic
  • Flow Rate
  • 1.0 to 1.5 mL/min.
  • For Use With (Application)
  • Cation Exchange
  • For Use With (Equipment)
  • RFIC Systems
  • Hydrophobicity
  • Medium
  • Solvent Compatibility
  • Acidic Eluents (pH 0 to 7), 0 to 10% HPLC Solvents, Alcohols Should be Avoided
  • Format
  • Standard Bore
  • Solvents
  • 0 to 10% HPLC Solvents, Alcohols Should be Avoided
  • Pressure
  • 3000 psi (207 bar)
  • Compatibility
  • Acidic Eluents (pH 0 to 7), 0 to 10% HPLC Solvents, Alcohols Should be Avoided
THM076028 Dionex™ IonPac™ CS19 IC Column, 4 µm, 2 × 250 mm 2269.21 
Add to Cart
  • Max. Pressure
  • 3000 psi (207 bar)
  • pH
  • 0 to 7
  • Stationary Phase
  • Super Macroporous Resin
  • Packing Material
  • Ethylvinylbenzene/Divinylbenzene
  • Column Type
  • Analytical Column
  • Phase
  • Super Macroporous Resin
  • Unit Size
  • Each 1
  • Type
  • Analytical Column
  • Crosslinking
  • 55% DVB
  • Column Capacity
  • 600 µeq
  • Column Chemistry
  • Acidic
  • Flow Rate
  • 0.25 to 0.375 mL/min.
  • For Use With (Application)
  • Cation Exchange
  • For Use With (Equipment)
  • RFIC Systems
  • Hydrophobicity
  • Medium
  • Solvent Compatibility
  • Acidic Eluents (pH 0 to 7), 0 to 10% HPLC Solvents, Alcohols Should be Avoided
  • Format
  • Microbore
  • Solvents
  • 0 to 10% HPLC Solvents, Alcohols Should be Avoided
  • Pressure
  • 3000 psi (207 bar)
  • Compatibility
  • Acidic Eluents (pH 0 to 7), 0 to 10% HPLC Solvents, Alcohols Should be Avoided
THM17326-012105 Accucore™ aQ C18 Polar Endcapped HPLC Column, 2.6 μm, 2.1 × 10 mm 798.04 
Add to Cart
  • Column Format
  • Guard Cartridge, 4 Pk.
  • For Use With
  • Uniguard Direct-Connection and Stand Alone Holder
  • Max. Pressure
  • 14500 psi (1000 bar)
  • pH
  • 2 to 9
  • Pore Size
  • 80 Å
  • Surface Area
  • 130 m²/g
  • Temperature
  • 70°C
  • USP Type
  • L1
  • Stationary Phase
  • C18
  • Product Line
  • Accucore
  • Packing Material
  • Spherical, Solid Core, Ultrapure Silica
  • Carbon Load
  • 9%
  • Column Type
  • Reversed Phase
  • Endcapped
  • Polar
  • Phase
  • C18
  • Unit Size
  • Pack of 4
  • Type
  • L1
  • Format
  • Guard Cartridge, 4 Pk.
  • Pressure
  • 14500 psi (1000 bar)
THM17326-013005 Accucore™ aQ C18 Polar Endcapped HPLC Column, 2.6 μm, 3 × 10 mm 798.04 
Add to Cart
  • Column Format
  • Guard Cartridge, 4 Pk.
  • For Use With
  • Uniguard Direct-Connection and Stand Alone Holder
  • Max. Pressure
  • 14500 psi (1000 bar)
  • pH
  • 2 to 9
  • Pore Size
  • 80 Å
  • Surface Area
  • 130 m²/g
  • Temperature
  • 70°C
  • USP Type
  • L1
  • Stationary Phase
  • C18
  • Product Line
  • Accucore
  • Packing Material
  • Spherical, Solid Core, Ultrapure Silica
  • Carbon Load
  • 9%
  • Column Type
  • Reversed Phase
  • Endcapped
  • Polar
  • Phase
  • C18
  • Unit Size
  • Pack of 4
  • Type
  • L1
  • Format
  • Guard Cartridge, 4 Pk.
  • Pressure
  • 14500 psi (1000 bar)
THM17326-014005 Accucore™ aQ C18 Polar Endcapped HPLC Column, 2.6 μm, 4.6 × 10 mm 1130.37 
Add to Cart
  • Column Format
  • Guard Cartridge, 4 Pk.
  • For Use With
  • Uniguard Direct-Connection and Stand Alone Holder
  • Max. Pressure
  • 14500 psi (1000 bar)
  • pH
  • 2 to 9
  • Pore Size
  • 80 Å
  • Surface Area
  • 130 m²/g
  • Temperature
  • 70°C
  • USP Type
  • L1
  • Stationary Phase
  • C18
  • Product Line
  • Accucore
  • Packing Material
  • Spherical, Solid Core, Ultrapure Silica
  • Carbon Load
  • 9%
  • Column Type
  • Reversed Phase
  • Endcapped
  • Polar
  • Phase
  • C18
  • Unit Size
  • -
  • Type
  • L1
  • Format
  • Guard Cartridge, 4 Pk.
  • Pressure
  • 14500 psi (1000 bar)
THM17326-052130 Accucore™ aQ C18 Polar Endcapped HPLC Column, 2.6 μm, 2.1 × 50 mm 1130.37 
Add to Cart
  • Column Format
  • Analytical Column
  • For Use With
  • HPLC
  • Max. Pressure
  • 14500 psi (1000 bar)
  • pH
  • 2 to 9
  • Pore Size
  • 80 Å
  • Surface Area
  • 130 m²/g
  • Temperature
  • 70°C
  • USP Type
  • L1
  • Stationary Phase
  • C18
  • Product Line
  • Accucore
  • Packing Material
  • Spherical, Solid Core, Ultrapure Silica
  • Carbon Load
  • 9%
  • Column Type
  • Reversed Phase
  • Endcapped
  • Polar
  • Phase
  • C18
  • Unit Size
  • Each
  • Type
  • L1
  • Flow Rate
  • 200 µL/min
  • Format
  • Analytical Column
  • Pressure
  • 14500 psi (1000 bar)
THM17326-053030 Accucore™ aQ C18 Polar Endcapped HPLC Column, 2.6 μm, 3 × 50 mm 1130.37 
Add to Cart
  • Column Format
  • Analytical Column
  • For Use With
  • HPLC
  • Max. Pressure
  • 14500 psi (1000 bar)
  • pH
  • 2 to 9
  • Pore Size
  • 80 Å
  • Surface Area
  • 130 m²/g
  • Temperature
  • 70°C
  • USP Type
  • L1
  • Stationary Phase
  • C18
  • Product Line
  • Accucore
  • Packing Material
  • Spherical, Solid Core, Ultrapure Silica
  • Carbon Load
  • 9%
  • Column Type
  • Reversed Phase
  • Endcapped
  • Polar
  • Phase
  • C18
  • Unit Size
  • Each
  • Type
  • L1
  • Format
  • Analytical Column
  • Pressure
  • 14500 psi (1000 bar)
THM17326-102130 Accucore™ aQ C18 Polar Endcapped HPLC Column, 2.6 μm, 2.1 × 100 mm 1329.35 
Add to Cart
  • Column Format
  • Analytical Column
  • For Use With
  • HPLC
  • Max. Pressure
  • 14500 psi (1000 bar)
  • pH
  • 2 to 9
  • Pore Size
  • 80 Å
  • Surface Area
  • 130 m²/g
  • Temperature
  • 70°C
  • USP Type
  • L1
  • Stationary Phase
  • C18
  • Product Line
  • Accucore
  • Packing Material
  • Spherical, Solid Core, Ultrapure Silica
  • Carbon Load
  • 9%
  • Column Type
  • Reversed Phase
  • Endcapped
  • Polar
  • Phase
  • C18
  • Unit Size
  • Each
  • Type
  • L1
  • Format
  • Analytical Column
  • Pressure
  • 14500 psi (1000 bar)

Overview

Solve your chromatography challenges with our extensive portfolio of HPLC and UHPLC columns designed to meet all of your separation needs. Bringing you a 40-year legacy of innovation, Thermo Scientific (U)HPLC columns offer an unmatched variety of chemistries, from the most popular C18 phases, to innovative mixed-mode chemistries, to the broadest range of solid core columns on the market, and more. We design our columns with everything you expect from a high-quality (U)HPLC column: high resolution, enhanced sensitivity, faster analysis, consistent performance, long column lifetime, and reproducibility. Each of our column types is available in a range of particle sizes and column formats so you can select the column best suited to your workflow.


Resources