THM072067
Dionex™ IonPac™ CS12A IC Column, 0.8 µm, 4 × 50 mm
749.35
Add to Cart
Max. Pressure
5000 psi (345 bar)
Stationary Phase
IonPac CG12A-8µm
Column Type
Guard Column
Phase
IonPac CG12A-8µm
Unit Size
Each 1
Type
Guard Column
Column Chemistry
Acidic
For Use With (Application)
IC-MS
For Use With (Equipment)
IC-MS Systems
Hydrophobicity
Medium
Solvent Compatibility
Acidic Eluents, 100% Acetonitrile, Alcohols Should be Avoided
Format
Capillary
Pressure
5000 psi (345 bar)
Compatibility
Acidic Eluents, 100% Acetonitrile, Alcohols Should be Avoided
THM072069
Dionex™ IonPac™ CS12A IC Column, 5 µm, 0.4 × 35 mm
749.35
Add to Cart
Max. Pressure
5000 psi (345 bar)
Stationary Phase
IonPac CS12A-5µm
Column Type
Guard Column
Phase
IonPac CS12A-5µm
Unit Size
Each 1
Type
Guard Column
Column Chemistry
Acidic
For Use With (Application)
IC-MS
For Use With (Equipment)
IC-MS Systems
Hydrophobicity
Medium
Solvent Compatibility
Acidic Eluents, 100% Acetonitrile, Alcohols Should be Avoided
Format
Capillary
Pressure
5000 psi (345 bar)
Compatibility
Acidic Eluents, 100% Acetonitrile, Alcohols Should be Avoided
THM046073
Dionex™ IonPac™ CS12A IC Column, 8 µm, 4 × 250 mm
2269.21
Add to Cart
Max. Pressure
4000 psi (275 bar)
Stationary Phase
IonPac CS12A-8µm
Packing Material
Ethylvinylbenzene/Divinylbenzene
Column Type
Analytical Column
Phase
IonPac CS12A-8µm
Unit Size
Each 1
Type
Analytical Column
Crosslinking
55% DVB
Column Capacity
2800 µeq
Column Chemistry
Acidic
Flow Rate
1.0 to 2.0 mL/min.
For Use With (Application)
Cation Exchange
For Use With (Equipment)
CSRS
Hydrophobicity
Medium
Solvent Compatibility
Acidic Eluents, 0 to 100% Acetonitrile, Alcohols Should be Avoided
Format
Standard Bore
Solvents
0 to 100% Acetonitrile. Alcohols Should be Avoided.
Pressure
4000 psi (275 bar)
Compatibility
Acidic Eluents, 0 to 100% Acetonitrile, Alcohols Should be Avoided
THM046075
Dionex™ IonPac™ CS12A IC Column, 8 µm, 2 × 250 mm
2269.21
Add to Cart
Max. Pressure
4000 psi (275 bar)
Stationary Phase
IonPac CS12A-8µm
Packing Material
Ethylvinylbenzene/Divinylbenzene
Column Type
Analytical Column
Phase
IonPac CS12A-8µm
Unit Size
Each 1
Type
Analytical Column
Crosslinking
55% DVB
Column Capacity
700 µeq
Column Chemistry
Acidic
Flow Rate
0.25 to 0.5 mL/min.
For Use With (Application)
Cation Exchange
For Use With (Equipment)
CSRS
Hydrophobicity
Medium
Solvent Compatibility
Acidic Eluents, 0 to 100% Acetonitrile, Alcohols Should be Avoided
Format
Microbore
Solvents
0 to 100% Acetonitrile. Alcohols Should be Avoided.
Pressure
4000 psi (275 bar)
Compatibility
Acidic Eluents, 0 to 100% Acetonitrile, Alcohols Should be Avoided
THM057185
Dionex™ IonPac™ CS12A IC Column, 5 µm, 3 × 150 mm
2269.21
Add to Cart
Max. Pressure
4000 psi (275 bar)
Stationary Phase
IonPac CS12A-5µm
Packing Material
Ethylvinylbenzene/Divinylbenzene
Column Type
Analytical Column
Phase
IonPac CS12A-5µm
Unit Size
Each 1
Type
Analytical Column
Crosslinking
55% DVB
Column Capacity
940 µeq
Column Chemistry
Acidic
Flow Rate
0.5 to 1.0 mL/min.
For Use With (Application)
Cation Exchange
For Use With (Equipment)
CSRS
Hydrophobicity
Medium
Solvent Compatibility
Acidic Eluents, 0 to 100% Acetonitrile, Alcohols Should be Avoided
Format
Microbore
Solvents
0 to 100% Acetonitrile. Alcohols Should be Avoided.
Pressure
4000 psi (275 bar)
Compatibility
Acidic Eluents, 0 to 100% Acetonitrile, Alcohols Should be Avoided
THM059960
Dionex™ IonPac™ CS12A IC Column, 2 × 100 mm, 8 µm
2269.21
Add to Cart
Max. Pressure
4000 psi (275 bar)
Stationary Phase
IonPac CS12A-MS
Packing Material
Ethylvinylbenzene/Divinylbenzene
Column Type
Analytical Column
Phase
IonPac CS12A-MS
Unit Size
Each 1
Type
Analytical Column
Crosslinking
55% DVB
Description
CS12 A-MS-8 µm (2 x 100 mm)
Column Capacity
280 µeq
Column Chemistry
Acidic
Flow Rate
0.25 to 0.75 mL/min.
For Use With (Application)
IC-MS, Cation Exchange
For Use With (Equipment)
IC-MS Systems
Hydrophobicity
Medium
Solvent Compatibility
Acidic Eluents, 0 to 100% Acetonitrile, Alcohols Should be Avoided
Format
Microbore
Solvents
0 to 100% Acetonitrile. Alcohols Should be Avoided.
Pressure
4000 psi (275 bar)
Compatibility
Acidic Eluents, 0 to 100% Acetonitrile, Alcohols Should be Avoided
THM072068
Dionex™ IonPac™ CS12A IC Column, 0.5 µm, 4 × 150 mm
2269.21
Add to Cart
Max. Pressure
5000 psi (345 bar)
Stationary Phase
IonPac CS12A-5µm
Packing Material
Ethylvinylbenzene/Divinylbenzene
Column Type
Capillary Column
Phase
IonPac CS12A-5µm
Unit Size
Each 1
Type
Capillary Column
Crosslinking
55% DVB
Column Capacity
9.4 µeq
Column Chemistry
Acidic
Flow Rate
0.008 to 0.20 mL/min.
For Use With (Application)
Separation of Group I and II Cations, Cation Exchange
For Use With (Equipment)
Separation of Group I and II Cations
Hydrophobicity
Medium
Solvent Compatibility
Acidic Eluents, 0 to 100% Acetonitrile, Alcohols Should be Avoided
Format
Capillary
Solvents
0 to 100% Acetonitrile. Alcohols Should be Avoided.
Pressure
5000 psi (345 bar)
Compatibility
Acidic Eluents, 0 to 100% Acetonitrile, Alcohols Should be Avoided
THM079914
Dionex™ IonPac™ CS12A IC Column, 0.8 µm, 4 × 250 mm
2269.21
Add to Cart
Max. Pressure
5000 psi (345 bar)
Stationary Phase
IonPac CS12A-8µm
Packing Material
Ethylvinylbenzene/Divinylbenzene
Column Type
Capillary Column
Phase
IonPac CS12A-8µm
Unit Size
Each 1
Type
Capillary Column
Crosslinking
55% DVB
Column Capacity
28 µeq
Column Chemistry
Acidic
Flow Rate
0.008 to 0.20 mL/min.
For Use With (Application)
Separation of Group I and II Cations, Cation Exchange
For Use With (Equipment)
Separation of Group I and II Cations
Hydrophobicity
Medium
Solvent Compatibility
Acidic Eluents, 0 to 100% Acetonitrile, Alcohols Should be Avoided
Solvents
0 to 100% Acetonitrile. Alcohols Should be Avoided.
Material
Ethylvinylbenzene/Divinylbenzene
THM079914
Dionex™ IonPac™ CS12A IC Column, 0.8 µm, 4 × 250 mm
2269.21
Add to Cart
Max. Pressure
5000 psi (345 bar)
Stationary Phase
IonPac CS12A-8µm
Packing Material
Ethylvinylbenzene/Divinylbenzene
Column Type
Capillary Column
Phase
IonPac CS12A-8µm
Unit Size
Each 1
Type
Capillary Column
Crosslinking
55% DVB
Column Capacity
28 µeq
Column Chemistry
Acidic
Flow Rate
0.008 to 0.20 mL/min.
For Use With (Application)
Separation of Group I and II Cations, Cation Exchange
For Use With (Equipment)
Separation of Group I and II Cations
Hydrophobicity
Medium
Solvent Compatibility
Acidic Eluents, 0 to 100% Acetonitrile, Alcohols Should be Avoided
Format
Capillary
Solvents
0 to 100% Acetonitrile. Alcohols Should be Avoided.
Pressure
5000 psi (345 bar)
Compatibility
Acidic Eluents, 0 to 100% Acetonitrile, Alcohols Should be Avoided
THM064151
Dionex™ IonPac™ AS24 Analytical & Guard Column, 11 µm, 2 × 50 mm
749.35
Add to Cart
Max. Pressure
3000 psi (207 bar)
Stationary Phase
IonPac AG24
Column Type
Guard Column
Phase
IonPac AG24
Unit Size
Each 1
Type
Guard Column
Column Capacity
1.5 µeq
Column Chemistry
Hydroxide
For Use With (Application)
Separation of Haloacetic Acids and Bromate in Drinking Water, Anion Exchange
For Use With (Equipment)
Separation of Haloacetic Acids and Bromate in Drinking Water
Hydrophobicity
Ultralow
Solvent Compatibility
pH 0 to 14, 0 to 100% HPLC Solvents
Format
Microbore
Solvents
Particle Size
Certifications/Compliance
U.S. EPA Method 557
Pressure
3000 psi (207 bar)
Compatibility
pH 0 to 14, 0 to 100% HPLC Solvents