+852-3069 6950
css@gugent.com.hk
 

Columns, cartridges, column packing materials, and accessories for use with ion, gas, and liquid chromatography systems and methods. A wide variety of stationary phases and column dimensions are available to accommodate specialized laboratory procedures.

Catalog No. Product Net Price
THM072067 Dionex™ IonPac™ CS12A IC Column, 0.8 µm, 4 × 50 mm 749.35 
Add to Cart
  • Max. Pressure
  • 5000 psi (345 bar)
  • Stationary Phase
  • IonPac CG12A-8µm
  • Column Type
  • Guard Column
  • Phase
  • IonPac CG12A-8µm
  • Unit Size
  • Each 1
  • Type
  • Guard Column
  • Column Chemistry
  • Acidic
  • For Use With (Application)
  • IC-MS
  • For Use With (Equipment)
  • IC-MS Systems
  • Hydrophobicity
  • Medium
  • Solvent Compatibility
  • Acidic Eluents, 100% Acetonitrile, Alcohols Should be Avoided
  • Format
  • Capillary
  • Pressure
  • 5000 psi (345 bar)
  • Compatibility
  • Acidic Eluents, 100% Acetonitrile, Alcohols Should be Avoided
THM072069 Dionex™ IonPac™ CS12A IC Column, 5 µm, 0.4 × 35 mm 749.35 
Add to Cart
  • Max. Pressure
  • 5000 psi (345 bar)
  • Stationary Phase
  • IonPac CS12A-5µm
  • Column Type
  • Guard Column
  • Phase
  • IonPac CS12A-5µm
  • Unit Size
  • Each 1
  • Type
  • Guard Column
  • Column Chemistry
  • Acidic
  • For Use With (Application)
  • IC-MS
  • For Use With (Equipment)
  • IC-MS Systems
  • Hydrophobicity
  • Medium
  • Solvent Compatibility
  • Acidic Eluents, 100% Acetonitrile, Alcohols Should be Avoided
  • Format
  • Capillary
  • Pressure
  • 5000 psi (345 bar)
  • Compatibility
  • Acidic Eluents, 100% Acetonitrile, Alcohols Should be Avoided
THM046073 Dionex™ IonPac™ CS12A IC Column, 8 µm, 4 × 250 mm 2269.21 
Add to Cart
  • Max. Pressure
  • 4000 psi (275 bar)
  • Stationary Phase
  • IonPac CS12A-8µm
  • Packing Material
  • Ethylvinylbenzene/Divinylbenzene
  • Column Type
  • Analytical Column
  • Phase
  • IonPac CS12A-8µm
  • Unit Size
  • Each 1
  • Type
  • Analytical Column
  • Crosslinking
  • 55% DVB
  • Column Capacity
  • 2800 µeq
  • Column Chemistry
  • Acidic
  • Flow Rate
  • 1.0 to 2.0 mL/min.
  • For Use With (Application)
  • Cation Exchange
  • For Use With (Equipment)
  • CSRS
  • Hydrophobicity
  • Medium
  • Solvent Compatibility
  • Acidic Eluents, 0 to 100% Acetonitrile, Alcohols Should be Avoided
  • Format
  • Standard Bore
  • Solvents
  • 0 to 100% Acetonitrile. Alcohols Should be Avoided.
  • Pressure
  • 4000 psi (275 bar)
  • Compatibility
  • Acidic Eluents, 0 to 100% Acetonitrile, Alcohols Should be Avoided
THM046075 Dionex™ IonPac™ CS12A IC Column, 8 µm, 2 × 250 mm 2269.21 
Add to Cart
  • Max. Pressure
  • 4000 psi (275 bar)
  • Stationary Phase
  • IonPac CS12A-8µm
  • Packing Material
  • Ethylvinylbenzene/Divinylbenzene
  • Column Type
  • Analytical Column
  • Phase
  • IonPac CS12A-8µm
  • Unit Size
  • Each 1
  • Type
  • Analytical Column
  • Crosslinking
  • 55% DVB
  • Column Capacity
  • 700 µeq
  • Column Chemistry
  • Acidic
  • Flow Rate
  • 0.25 to 0.5 mL/min.
  • For Use With (Application)
  • Cation Exchange
  • For Use With (Equipment)
  • CSRS
  • Hydrophobicity
  • Medium
  • Solvent Compatibility
  • Acidic Eluents, 0 to 100% Acetonitrile, Alcohols Should be Avoided
  • Format
  • Microbore
  • Solvents
  • 0 to 100% Acetonitrile. Alcohols Should be Avoided.
  • Pressure
  • 4000 psi (275 bar)
  • Compatibility
  • Acidic Eluents, 0 to 100% Acetonitrile, Alcohols Should be Avoided
THM057185 Dionex™ IonPac™ CS12A IC Column, 5 µm, 3 × 150 mm 2269.21 
Add to Cart
  • Max. Pressure
  • 4000 psi (275 bar)
  • Stationary Phase
  • IonPac CS12A-5µm
  • Packing Material
  • Ethylvinylbenzene/Divinylbenzene
  • Column Type
  • Analytical Column
  • Phase
  • IonPac CS12A-5µm
  • Unit Size
  • Each 1
  • Type
  • Analytical Column
  • Crosslinking
  • 55% DVB
  • Column Capacity
  • 940 µeq
  • Column Chemistry
  • Acidic
  • Flow Rate
  • 0.5 to 1.0 mL/min.
  • For Use With (Application)
  • Cation Exchange
  • For Use With (Equipment)
  • CSRS
  • Hydrophobicity
  • Medium
  • Solvent Compatibility
  • Acidic Eluents, 0 to 100% Acetonitrile, Alcohols Should be Avoided
  • Format
  • Microbore
  • Solvents
  • 0 to 100% Acetonitrile. Alcohols Should be Avoided.
  • Pressure
  • 4000 psi (275 bar)
  • Compatibility
  • Acidic Eluents, 0 to 100% Acetonitrile, Alcohols Should be Avoided
THM059960 Dionex™ IonPac™ CS12A IC Column, 2 × 100 mm, 8 µm 2269.21 
Add to Cart
  • Max. Pressure
  • 4000 psi (275 bar)
  • Stationary Phase
  • IonPac CS12A-MS
  • Packing Material
  • Ethylvinylbenzene/Divinylbenzene
  • Column Type
  • Analytical Column
  • Phase
  • IonPac CS12A-MS
  • Unit Size
  • Each 1
  • Type
  • Analytical Column
  • Crosslinking
  • 55% DVB
  • Description
  • CS12 A-MS-8 µm (2 x 100 mm)
  • Column Capacity
  • 280 µeq
  • Column Chemistry
  • Acidic
  • Flow Rate
  • 0.25 to 0.75 mL/min.
  • For Use With (Application)
  • IC-MS, Cation Exchange
  • For Use With (Equipment)
  • IC-MS Systems
  • Hydrophobicity
  • Medium
  • Solvent Compatibility
  • Acidic Eluents, 0 to 100% Acetonitrile, Alcohols Should be Avoided
  • Format
  • Microbore
  • Solvents
  • 0 to 100% Acetonitrile. Alcohols Should be Avoided.
  • Pressure
  • 4000 psi (275 bar)
  • Compatibility
  • Acidic Eluents, 0 to 100% Acetonitrile, Alcohols Should be Avoided
THM072068 Dionex™ IonPac™ CS12A IC Column, 0.5 µm, 4 × 150 mm 2269.21 
Add to Cart
  • Max. Pressure
  • 5000 psi (345 bar)
  • Stationary Phase
  • IonPac CS12A-5µm
  • Packing Material
  • Ethylvinylbenzene/Divinylbenzene
  • Column Type
  • Capillary Column
  • Phase
  • IonPac CS12A-5µm
  • Unit Size
  • Each 1
  • Type
  • Capillary Column
  • Crosslinking
  • 55% DVB
  • Column Capacity
  • 9.4 µeq
  • Column Chemistry
  • Acidic
  • Flow Rate
  • 0.008 to 0.20 mL/min.
  • For Use With (Application)
  • Separation of Group I and II Cations, Cation Exchange
  • For Use With (Equipment)
  • Separation of Group I and II Cations
  • Hydrophobicity
  • Medium
  • Solvent Compatibility
  • Acidic Eluents, 0 to 100% Acetonitrile, Alcohols Should be Avoided
  • Format
  • Capillary
  • Solvents
  • 0 to 100% Acetonitrile. Alcohols Should be Avoided.
  • Pressure
  • 5000 psi (345 bar)
  • Compatibility
  • Acidic Eluents, 0 to 100% Acetonitrile, Alcohols Should be Avoided
THM079914 Dionex™ IonPac™ CS12A IC Column, 0.8 µm, 4 × 250 mm 2269.21 
Add to Cart
  • Max. Pressure
  • 5000 psi (345 bar)
  • Stationary Phase
  • IonPac CS12A-8µm
  • Packing Material
  • Ethylvinylbenzene/Divinylbenzene
  • Column Type
  • Capillary Column
  • Phase
  • IonPac CS12A-8µm
  • Unit Size
  • Each 1
  • Type
  • Capillary Column
  • Crosslinking
  • 55% DVB
  • Column Capacity
  • 28 µeq
  • Column Chemistry
  • Acidic
  • Flow Rate
  • 0.008 to 0.20 mL/min.
  • For Use With (Application)
  • Separation of Group I and II Cations, Cation Exchange
  • For Use With (Equipment)
  • Separation of Group I and II Cations
  • Hydrophobicity
  • Medium
  • Solvent Compatibility
  • Acidic Eluents, 0 to 100% Acetonitrile, Alcohols Should be Avoided
  • Solvents
  • 0 to 100% Acetonitrile. Alcohols Should be Avoided.
  • Material
  • Ethylvinylbenzene/Divinylbenzene
THM079914 Dionex™ IonPac™ CS12A IC Column, 0.8 µm, 4 × 250 mm 2269.21 
Add to Cart
  • Max. Pressure
  • 5000 psi (345 bar)
  • Stationary Phase
  • IonPac CS12A-8µm
  • Packing Material
  • Ethylvinylbenzene/Divinylbenzene
  • Column Type
  • Capillary Column
  • Phase
  • IonPac CS12A-8µm
  • Unit Size
  • Each 1
  • Type
  • Capillary Column
  • Crosslinking
  • 55% DVB
  • Column Capacity
  • 28 µeq
  • Column Chemistry
  • Acidic
  • Flow Rate
  • 0.008 to 0.20 mL/min.
  • For Use With (Application)
  • Separation of Group I and II Cations, Cation Exchange
  • For Use With (Equipment)
  • Separation of Group I and II Cations
  • Hydrophobicity
  • Medium
  • Solvent Compatibility
  • Acidic Eluents, 0 to 100% Acetonitrile, Alcohols Should be Avoided
  • Format
  • Capillary
  • Solvents
  • 0 to 100% Acetonitrile. Alcohols Should be Avoided.
  • Pressure
  • 5000 psi (345 bar)
  • Compatibility
  • Acidic Eluents, 0 to 100% Acetonitrile, Alcohols Should be Avoided
THM064151 Dionex™ IonPac™ AS24 Analytical & Guard Column, 11 µm, 2 × 50 mm 749.35 
Add to Cart
  • Max. Pressure
  • 3000 psi (207 bar)
  • Stationary Phase
  • IonPac AG24
  • Column Type
  • Guard Column
  • Phase
  • IonPac AG24
  • Unit Size
  • Each 1
  • Type
  • Guard Column
  • Column Capacity
  • 1.5 µeq
  • Column Chemistry
  • Hydroxide
  • For Use With (Application)
  • Separation of Haloacetic Acids and Bromate in Drinking Water, Anion Exchange
  • For Use With (Equipment)
  • Separation of Haloacetic Acids and Bromate in Drinking Water
  • Hydrophobicity
  • Ultralow
  • Solvent Compatibility
  • pH 0 to 14, 0 to 100% HPLC Solvents
  • Format
  • Microbore
  • Solvents
  • Particle Size
  • Certifications/Compliance
  • U.S. EPA Method 557
  • Pressure
  • 3000 psi (207 bar)
  • Compatibility
  • pH 0 to 14, 0 to 100% HPLC Solvents

Overview

Solve your chromatography challenges with our extensive portfolio of HPLC and UHPLC columns designed to meet all of your separation needs. Bringing you a 40-year legacy of innovation, Thermo Scientific (U)HPLC columns offer an unmatched variety of chemistries, from the most popular C18 phases, to innovative mixed-mode chemistries, to the broadest range of solid core columns on the market, and more. We design our columns with everything you expect from a high-quality (U)HPLC column: high resolution, enhanced sensitivity, faster analysis, consistent performance, long column lifetime, and reproducibility. Each of our column types is available in a range of particle sizes and column formats so you can select the column best suited to your workflow.


Resources