+852-3069 6950
css@gugent.com.hk
 

Columns, cartridges, column packing materials, and accessories for use with ion, gas, and liquid chromatography systems and methods. A wide variety of stationary phases and column dimensions are available to accommodate specialized laboratory procedures.

Catalog No. Product Net Price
THM078840 Dionex™ IonPac™ CS19-4µm IC Column, 8 µm, 4 × 50 mm 810.73 
Add to Cart
  • Max. Pressure
  • 5000 psi (345 bar)
  • Stationary Phase
  • IonPac CG19-4µm
  • Column Type
  • Guard Column
  • Phase
  • IonPac CG19-4µm
  • Unit Size
  • Each 1
  • Type
  • Guard Column
  • Column Capacity
  • 46 µeq
  • For Use With (Application)
  • Cation Exchange
  • Hydrophobicity
  • Medium
  • Solvent Compatibility
  • Acidic Eluents (pH 0 to 7), 10% HPLC Solvents, Alcohols Should be Avoided
  • Format
  • Standard Bore
  • Pressure
  • 5000 psi (345 bar)
  • Compatibility
  • Acidic Eluents (pH 0 to 7), 10% HPLC Solvents, Alcohols Should be Avoided
THM078835 Dionex™ IonPac™ CS19-4µm IC Column, 4 µm, 0.4 × 250 mm 2468.19 
Add to Cart
  • Max. Pressure
  • 5000 psi (345 bar)
  • pH
  • 0 to 7
  • Stationary Phase
  • IonPac CS19-4µm
  • Column Type
  • Capillary Separator
  • Phase
  • IonPac CS19-4µm
  • Unit Size
  • Each 1
  • Type
  • Capillary Separator
  • Crosslinking
  • 55% DVB
  • Column Capacity
  • 24 µeq
  • Flow Rate
  • 13 μL/min.
  • For Use With (Application)
  • Cation Exchange
  • Hydrophobicity
  • Medium
  • Ion Exchange Group
  • Grafted Carboxylic Acid
  • Solvent Compatibility
  • Acidic Eluents (pH 0 to 7), 10% HPLC Solvents, Alcohols Should be Avoided
  • Format
  • Capillary
  • Solvents
  • 10% HPLC Solvents, Alcohols Should be Avoided.
  • Column Construction
  • PEEK with 10-32 Threaded Ferrule-Style End Fittings. All Components Are Nonmetallic.
  • Pressure
  • 5000 psi (345 bar)
  • Compatibility
  • Acidic Eluents (pH 0 to 7), 10% HPLC Solvents, Alcohols Should be Avoided
THM078836 Dionex™ IonPac™ CS19-4µm IC Column, 4 µm, 2 × 250 mm 2468.19 
Add to Cart
  • Max. Pressure
  • 5000 psi (345 bar)
  • pH
  • 0 to 7
  • Stationary Phase
  • IonPac CS19-4µm
  • Column Type
  • Separator Column
  • Phase
  • IonPac CS19-4µm
  • Unit Size
  • Each 1
  • Type
  • Separator Column
  • Crosslinking
  • 55% DVB
  • Column Capacity
  • 600 µeq
  • For Use With (Application)
  • Cation Exchange
  • Hydrophobicity
  • Medium
  • Ion Exchange Group
  • Grafted Carboxylic Acid
  • Solvent Compatibility
  • Acidic Eluents (pH0to7),10% HPLC Solvents,Alcohols Should be Avoided
  • Format
  • Microbore
  • Solvents
  • 10% HPLC Solvents, Alcohols Should be Avoided.
  • Column Construction
  • PEEK with 10-32 Threaded Ferrule-Style End Fittings. All Components Are Nonmetallic.
  • Pressure
  • 5000 psi (345 bar)
  • Compatibility
  • Acidic Eluents (pH0to7),10% HPLC Solvents,Alcohols Should be Avoided
THM078837 Dionex™ IonPac™ CS19-4µm IC Column, 4 µm, 4 × 250 mm 2468.19 
Add to Cart
  • Max. Pressure
  • 5000 psi (345 bar)
  • pH
  • 0 to 7
  • Stationary Phase
  • IonPac CS19-4µm
  • Column Type
  • Analytical Column
  • Phase
  • IonPac CS19-4µm
  • Unit Size
  • Each 1
  • Type
  • Analytical Column
  • Crosslinking
  • 55% DVB
  • Column Capacity
  • 2410 µeq
  • For Use With (Application)
  • Cation Exchange
  • Hydrophobicity
  • Medium
  • Ion Exchange Group
  • Grafted Carboxylic Acid
  • Solvent Compatibility
  • Acidic Eluents (pH 0 to 7), 10% HPLC Solvents, Alcohols Should be Avoided
  • Format
  • Standard Bore
  • Solvents
  • 10% HPLC Solvents, Alcohols Should be Avoided.
  • Column Construction
  • PEEK with 10-32 Threaded Ferrule-Style End Fittings. All Components Are Nonmetallic.
  • Pressure
  • 5000 psi (345 bar)
  • Compatibility
  • Acidic Eluents (pH 0 to 7), 10% HPLC Solvents, Alcohols Should be Avoided
THM076033 Dionex™ IonPac™ AS18-Fast-4µm IC Column, 13 µm, 0.4 × 35 mm 810.73 
Add to Cart
  • Max. Pressure
  • 5000 psi (345 bar)
  • Stationary Phase
  • Microporous Resin
  • Column Type
  • Guard Column
  • Phase
  • Microporous Resin
  • Unit Size
  • Each 1
  • Type
  • Guard Column
  • Crosslinking
  • 55% DVB
  • Column Capacity
  • 0.042 µeq
  • For Use With (Application)
  • Anion Exchange
  • Hydrophobicity
  • Low
  • Solvent Compatibility
  • pH 0 to 14, 0 to 100% HPLC Solvents
  • Format
  • Capillary
  • Solvents
  • Particle Size
  • Certifications/Compliance
  • U.S. EPA Methods 300.0 (A) and 300.1
  • Resin Composition
  • Microporous
  • Pressure
  • 5000 psi (345 bar)
  • Compatibility
  • pH 0 to 14, 0 to 100% HPLC Solvents
THM076035 Dionex™ IonPac™ AS18-Fast-4µm IC Column, 13 µm, 4 × 30 mm 810.73 
Add to Cart
  • Max. Pressure
  • 5000 psi (345 bar)
  • Stationary Phase
  • Microporous Resin
  • Column Type
  • Guard Column
  • Phase
  • Microporous Resin
  • Unit Size
  • Each 1
  • Type
  • Guard Column
  • Column Capacity
  • 4.2 µeq
  • For Use With (Application)
  • Anion Exchange
  • Hydrophobicity
  • Low
  • Solvent Compatibility
  • pH 0 to 14, 0 to 100% HPLC Solvents
  • Format
  • Standard Bore
  • Solvents
  • Particle Size
  • Certifications/Compliance
  • U.S. EPA Methods 300.0 (A) and 300.1
  • Pressure
  • 5000 psi (345 bar)
  • Compatibility
  • pH 0 to 14, 0 to 100% HPLC Solvents
THM076037 Dionex™ IonPac™ AS18-Fast-4µm IC Column, 13 µm, 2 × 30 mm 810.73 
Add to Cart
  • Max. Pressure
  • 5000 psi (345 bar)
  • Stationary Phase
  • Microporous Resin
  • Column Type
  • Guard Column
  • Phase
  • Microporous Resin
  • Unit Size
  • Each 1
  • Type
  • Guard Column
  • Crosslinking
  • 55% DVB
  • Column Capacity
  • 1.05 µeq
  • For Use With (Application)
  • Anion Exchange
  • Hydrophobicity
  • Low
  • Solvent Compatibility
  • pH 0 to 14, 0 to 100% HPLC Solvents
  • Format
  • Microbore
  • Solvents
  • Particle Size
  • Certifications/Compliance
  • U.S. EPA Methods 300.0 (A) and 300.1
  • Resin Composition
  • Microporous
  • Pressure
  • 5000 psi (345 bar)
  • Compatibility
  • pH 0 to 14, 0 to 100% HPLC Solvents
THM076034 Dionex™ IonPac™ AS18-Fast-4µm IC Column, 4 µm, 4 × 150 mm 2468.19 
Add to Cart
  • Max. Pressure
  • 5000 psi (345 bar)
  • Pore Size
  • 2000 Å
  • Stationary Phase
  • Super Macroporous Resin
  • Column Type
  • Analytical Column
  • Phase
  • Super Macroporous Resin
  • Unit Size
  • Each 1
  • Type
  • Analytical Column
  • Crosslinking
  • 55% DVB
  • Column Capacity
  • 174 µeq
  • Flow Rate
  • 1.5 mL/min.
  • For Use With (Application)
  • Anion Exchange
  • Hydrophobicity
  • Low
  • Solvent Compatibility
  • pH 0 to 14, 0 to 100% HPLC Solvents
  • Format
  • Standard Bore
  • Solvents
  • Particle Size
  • Column Construction
  • PEEK with 10-32 Threaded Ferrule-Style End Fittings. All Components Are Nonmetallic.
  • Certifications/Compliance
  • U.S. EPA Methods 300.0 (A) and 300.1
  • Resin Composition
  • Super Macroporous
  • Pressure
  • 5000 psi (345 bar)
  • Compatibility
  • pH 0 to 14, 0 to 100% HPLC Solvents
THM076036 Dionex™ IonPac™ AS18-Fast-4µm IC Column, 4 µm, 2 × 150 mm 2468.19 
Add to Cart
  • Max. Pressure
  • 5000 psi (345 bar)
  • Pore Size
  • 2000 Å
  • Stationary Phase
  • Super Macroporous Resin
  • Column Type
  • Analytical Column
  • Phase
  • Super Macroporous Resin
  • Unit Size
  • Each 1
  • Type
  • Analytical Column
  • Crosslinking
  • 55% DVB
  • Column Capacity
  • 43.5 µeq
  • Flow Rate
  • 0.38 mL/min.
  • For Use With (Application)
  • Anion Exchange
  • Hydrophobicity
  • Low
  • Solvent Compatibility
  • pH 0 to 14, 0 to 100% HPLC Solvents
  • Format
  • Microbore
  • Solvents
  • Particle Size
  • Column Construction
  • PEEK with 10-32 Threaded Ferrule-Style End Fittings. All Components Are Nonmetallic.
  • Certifications/Compliance
  • U.S. EPA Methods 300.0 (A) and 300.1
  • Resin Composition
  • Super Macroporous
  • Pressure
  • 5000 psi (345 bar)
  • Compatibility
  • pH 0 to 14, 0 to 100% HPLC Solvents
THM082314 Dionex™ IonPac™ AS18-Fast-4µm IC Column, 0.4 µm, 4 × 150 mm 2468.19 
Add to Cart
  • Diameter (Metric) Latex
  • 65 nm
  • Max. Pressure
  • 5000 psi (345 bar)
  • Pore Size
  • 2000 Å
  • Stationary Phase
  • Super Macroporous Resin
  • Column Type
  • Capillary Separator
  • Phase
  • Super Macroporous Resin
  • Unit Size
  • Each 1
  • Type
  • Capillary Separator
  • Crosslinking
  • 55% DVB
  • Column Capacity
  • 1.74 µeq
  • Flow Rate
  • 10 μL/min.
  • For Use With (Application)
  • Anion Exchange
  • Hydrophobicity
  • Low
  • Solvent Compatibility
  • pH 0 to 14, 0 to 100% HPLC Solvents
  • Solvents
  • Particle Size
  • Certifications/Compliance
  • U.S. EPA Method 300.0 (A)

Overview

Solve your chromatography challenges with our extensive portfolio of HPLC and UHPLC columns designed to meet all of your separation needs. Bringing you a 40-year legacy of innovation, Thermo Scientific (U)HPLC columns offer an unmatched variety of chemistries, from the most popular C18 phases, to innovative mixed-mode chemistries, to the broadest range of solid core columns on the market, and more. We design our columns with everything you expect from a high-quality (U)HPLC column: high resolution, enhanced sensitivity, faster analysis, consistent performance, long column lifetime, and reproducibility. Each of our column types is available in a range of particle sizes and column formats so you can select the column best suited to your workflow.


Resources