+852-3069 6950
css@gugent.com.hk
 

Columns, cartridges, column packing materials, and accessories for use with ion, gas, and liquid chromatography systems and methods. A wide variety of stationary phases and column dimensions are available to accommodate specialized laboratory procedures.

Catalog No. Product Net Price
THM063419 DNAPac™ PA200 Oligonucleotide HPLC Column, 8 μm, 9 × 50 mm 1534.68 
Add to Cart
  • Column Format
  • Guard Column
  • For Use With
  • HPAE-PAD
  • Max. Pressure
  • 4000 psi (275 bar)
  • pH
  • 2.5 to 12.5
  • Pore Size
  • Nonporous
  • Temperature
  • 85°C
  • Stationary Phase
  • Quaternary Ammonium
  • Product Line
  • DNAPac
  • Packing Material
  • Nonporous Polymer
  • Column Type
  • Ion Exchange
  • Phase
  • Quaternary Ammonium
  • Unit Size
  • Each
  • Type
  • Ion Exchange
  • Format
  • Guard Column
  • Pressure
  • 4000 psi (275 bar)
THM063000 DNAPac™ PA200 Oligonucleotide HPLC Column, 8 μm, 4 × 250 mm 2097.75 
Add to Cart
  • Column Format
  • Analytical Column
  • For Use With
  • UltiMate 3000 Titanium System
  • Max. Pressure
  • 4000 psi (275 bar)
  • pH
  • 2.5 to 12.5
  • Pore Size
  • Nonporous
  • Temperature
  • 85°C
  • Stationary Phase
  • Quaternary Ammonium
  • Product Line
  • DNAPac
  • Packing Material
  • Spherical, Nonporous Polymer
  • Column Type
  • Ion Exchange
  • Phase
  • Quaternary Ammonium
  • Unit Size
  • Each
  • Type
  • Ion Exchange
  • Mobile Phase Compatibility
  • pH 2 to 12.5, 100% compatible with common organic solvents, Ionic form eluents: chloride, perchlorate
  • Technique
  • Nucleic Acid/Anion Exchange
  • Flow Rate
  • 1.2 mL/min
  • Format
  • Analytical Column
  • Pressure
  • 4000 psi (275 bar)
  • Compatibility
  • pH 2 to 12.5, 100% compatible with common organic solvents, Ionic form eluents: chloride, perchlorate
THM088781 DNAPac™ PA200 Oligonucleotide HPLC Column, 8 μm, 22 × 250 mm 2097.75 
Add to Cart
  • Column Format
  • Preparative Column
  • Max. Pressure
  • 4000 psi (275 bar)
  • pH
  • 4 to 10
  • Pore Size
  • Nonporous
  • Temperature
  • 85°C
  • Stationary Phase
  • Quaternary Ammonium
  • Product Line
  • DNAPac
  • Packing Material
  • Nonporous Polymer
  • Column Type
  • Ion Exchange
  • Phase
  • Quaternary Ammonium
  • Unit Size
  • Each
  • Type
  • Ion Exchange
  • Technique
  • Nucleic Acid/Anion Exchange
  • Format
  • Preparative Column
  • Pressure
  • 4000 psi (275 bar)
THM063425 DNAPac™ PA200 Oligonucleotide HPLC Column, 2 × 250 mm, 8 μm 2118.91 
Add to Cart
  • Column Format
  • Analytical Column
  • For Use With
  • UltiMate 3000 Titanium System
  • Max. Pressure
  • 4000 psi (275 bar)
  • pH
  • 2.5 to 12.5
  • Pore Size
  • Nonporous
  • Temperature
  • 85°C
  • Stationary Phase
  • Quaternary Ammonium
  • Product Line
  • DNAPac
  • Packing Material
  • Spherical, Nonporous Polymer
  • Column Type
  • Ion Exchange
  • Phase
  • Quaternary Ammonium
  • Unit Size
  • Each
  • Type
  • Ion Exchange
  • Mobile Phase Compatibility
  • pH 2 to 12.5, 100% compatible with common organic solvents, Ionic form eluents: chloride, perchlorate
  • Technique
  • Nucleic Acid/Anion Exchange
  • Flow Rate
  • 1.2 mL/min
  • Format
  • Analytical Column
  • Pressure
  • 4000 psi (275 bar)
  • Compatibility
  • pH 2 to 12.5, 100% compatible with common organic solvents, Ionic form eluents: chloride, perchlorate
THM082508 DNAPac™ PA200 Oligonucleotide HPLC Column, 4 μm, 4.6 × 50 mm 3130.75 
Add to Cart
  • Column Format
  • Analytical Column
  • For Use With
  • UltiMate 3000 Titanium System
  • Max. Pressure
  • 10000 psi (690 bar)
  • pH
  • 2.5 to 12.5
  • Pore Size
  • Nonporous
  • Temperature
  • 85°C
  • Stationary Phase
  • Quaternary Ammonium
  • Product Line
  • DNAPac
  • Packing Material
  • Spherical, Nonporous Polymer
  • Column Type
  • Ion Exchange
  • Phase
  • Quaternary Ammonium
  • Unit Size
  • Each
  • Type
  • Ion Exchange
  • Technique
  • Nucleic Acid/Anion Exchange
  • Format
  • Analytical Column
  • Pressure
  • 10000 psi (690 bar)
THM082509 DNAPac™ PA200 Oligonucleotide HPLC Column, 4 μm, 4.6 × 150 mm 3867.4 
Add to Cart
  • Column Format
  • Analytical Column
  • For Use With
  • UltiMate 3000 Titanium System
  • Max. Pressure
  • 10000 psi (690 bar)
  • pH
  • 2.5 to 12.5
  • Pore Size
  • Nonporous
  • Temperature
  • 85°C
  • Stationary Phase
  • Quaternary Ammonium
  • Product Line
  • DNAPac
  • Packing Material
  • Spherical, Nonporous Polymer
  • Column Type
  • Ion Exchange
  • Phase
  • Quaternary Ammonium
  • Unit Size
  • Each
  • Type
  • Ion Exchange
  • Technique
  • Nucleic Acid/Anion Exchange
  • Format
  • Analytical Column
  • Pressure
  • 10000 psi (690 bar)
THM088780 DNAPac™ PA200 Oligonucleotide HPLC Column, 28 μm, 2 × 50 mm 4070.6 
Add to Cart
  • Column Format
  • Preparative Column
  • For Use With
  • Guard Column Requires Use of Preparative Guard Holder (Catalog #854-00)
  • Max. Pressure
  • 4000 psi (275 bar)
  • pH
  • 4 to 10
  • Pore Size
  • Nonporous
  • Temperature
  • 85°C
  • Stationary Phase
  • Quaternary Ammonium
  • Product Line
  • DNAPac
  • Packing Material
  • Nonporous Polymer
  • Column Type
  • Ion Exchange
  • Phase
  • Quaternary Ammonium
  • Unit Size
  • Each
  • Type
  • Ion Exchange
  • Format
  • Preparative Column
  • Pressure
  • 4000 psi (275 bar)
THM082510 DNAPac™ PA200 Oligonucleotide HPLC Column, 4 μm, 4.6 × 250 mm 4174.33 
Add to Cart
  • Column Format
  • Analytical Column
  • For Use With
  • UltiMate 3000 Titanium System
  • Max. Pressure
  • 10000 psi (690 bar)
  • pH
  • 2.5 to 12.5
  • Pore Size
  • Nonporous
  • Temperature
  • 85°C
  • Stationary Phase
  • Quaternary Ammonium
  • Product Line
  • DNAPac
  • Packing Material
  • Spherical, Nonporous Polymer
  • Column Type
  • Ion Exchange
  • Phase
  • Quaternary Ammonium
  • Unit Size
  • Each
  • Type
  • Ion Exchange
  • Technique
  • Nucleic Acid/Anion Exchange
  • Format
  • Analytical Column
  • Pressure
  • 10000 psi (690 bar)
THM063421 DNAPac™ PA200 Oligonucleotide HPLC Column, 9 × 250 mm, 8 μm 4538.42 
Add to Cart
  • Column Format
  • Analytical Column
  • For Use With
  • UltiMate 3000 Titanium System
  • Max. Pressure
  • 4000 psi (275 bar)
  • pH
  • 2.5 to 12.5
  • Pore Size
  • Nonporous
  • Temperature
  • 85°C
  • Stationary Phase
  • Quaternary Ammonium
  • Product Line
  • DNAPac
  • Packing Material
  • Spherical, Nonporous Polymer
  • Column Type
  • Ion Exchange
  • Phase
  • Quaternary Ammonium
  • Unit Size
  • Each
  • Type
  • Ion Exchange
  • Mobile Phase Compatibility
  • pH 2 to 12.5, 100% compatible with common organic solvents, Ionic form eluents: chloride, perchlorate
  • Technique
  • Nucleic Acid/Anion Exchange
  • Flow Rate
  • 1.2 mL/min
  • Format
  • Analytical Column
  • Pressure
  • 4000 psi (275 bar)
  • Compatibility
  • pH 2 to 12.5, 100% compatible with common organic solvents, Ionic form eluents: chloride, perchlorate
THM088781 DNAPac™ PA200 Oligonucleotide HPLC Column, 8 μm, 22 × 250 mm Special offer 
Add to Cart
  • Column Format
  • Preparative Column
  • Max. Pressure
  • 4000 psi (275 bar)
  • pH
  • 4 to 10
  • Pore Size
  • Nonporous
  • Temperature
  • 85°C
  • Stationary Phase
  • Quaternary Ammonium
  • Product Line
  • DNAPac
  • Packing Material
  • Nonporous Polymer
  • Column Type
  • Ion Exchange
  • Phase
  • Quaternary Ammonium
  • Unit Size
  • Each
  • Type
  • Ion Exchange
  • Material
  • Nonporous Polymer

Overview

Solve your chromatography challenges with our extensive portfolio of HPLC and UHPLC columns designed to meet all of your separation needs. Bringing you a 40-year legacy of innovation, Thermo Scientific (U)HPLC columns offer an unmatched variety of chemistries, from the most popular C18 phases, to innovative mixed-mode chemistries, to the broadest range of solid core columns on the market, and more. We design our columns with everything you expect from a high-quality (U)HPLC column: high resolution, enhanced sensitivity, faster analysis, consistent performance, long column lifetime, and reproducibility. Each of our column types is available in a range of particle sizes and column formats so you can select the column best suited to your workflow.


Resources