+852-3069 6950
css@gugent.com.hk
 

Columns, cartridges, column packing materials, and accessories for use with ion, gas, and liquid chromatography systems and methods. A wide variety of stationary phases and column dimensions are available to accommodate specialized laboratory procedures.

Catalog No. Product Net Price
THM41505-259570XL Hypersil™ PREP HS Phenyl HPLC Column, 5 μm, 50 × 250 mm 20930.92 
Add to Cart
  • Column Format
  • Preparative Column, XtendedLife
  • Max. Pressure
  • 2000 psi (140 bar)
  • pH
  • 2 to 8
  • Pore Size
  • 100 Å
  • Surface Area
  • 350 m²/g
  • Temperature
  • 60°C
  • USP Type
  • L11
  • Stationary Phase
  • Phenyl (Ph)
  • Packing Material
  • Spherical, Fully Porous, Ultrapure Silica
  • Carbon Load
  • 9%
  • Column Type
  • Reversed Phase
  • Endcapped
  • Yes
  • Phase
  • Phenyl (Ph)
  • Unit Size
  • Each
  • Type
  • L11
  • Material
  • Spherical, Fully Porous, Ultrapure Silica
THM41505-259570XL Hypersil™ PREP HS Phenyl HPLC Column, 5 μm, 50 × 250 mm 20930.92 
Add to Cart
  • Column Format
  • Preparative Column, XtendedLife
  • Max. Pressure
  • 2000 psi (140 bar)
  • pH
  • 2 to 8
  • Pore Size
  • 100 Å
  • Surface Area
  • 350 m²/g
  • Temperature
  • 60°C
  • USP Type
  • L11
  • Stationary Phase
  • Phenyl (Ph)
  • Packing Material
  • Spherical, Fully Porous, Ultrapure Silica
  • Carbon Load
  • 9%
  • Column Type
  • Reversed Phase
  • Endcapped
  • Yes
  • Phase
  • Phenyl (Ph)
  • Unit Size
  • Each
  • Type
  • L11
  • Format
  • Preparative Column, XtendedLife
  • Pressure
  • 2000 psi (140 bar)
THM088955 Dionex™ CarboPac™ PA210-Fast-4µm Column, 4 µm, 4 × 30 mm 757.81 
Add to Cart
  • Max. Pressure
  • 4000 psi (275 bar)
  • pH
  • 1 to 14
  • Stationary Phase
  • Ethylvinylbenzene/Divinylbenzene Substrate
  • Column Type
  • Guard Column
  • Phase
  • Ethylvinylbenzene/Divinylbenzene Substrate
  • Unit Size
  • Each
  • Type
  • Guard Column
  • Description
  • CarboPac PA210-4µm Guard Column
  • Column Capacity
  • 66 µeq
  • Flow Rate
  • 0.2 to 0.8 mL/min.
  • For Use With (Application)
  • Carbohydrate Analysis
  • For Use With (Equipment)
  • CarboPac PA210-4µm Analytical Column
  • Solvent Compatibility
  • pH 0 to 14, 80% Compatible with Common HPLC Solvents
  • Solvents
  • Particle Size
THM088955 Dionex™ CarboPac™ PA210-Fast-4µm Column, 4 µm, 4 × 30 mm 757.81 
Add to Cart
  • Max. Pressure
  • 4000 psi (275 bar)
  • pH
  • 1 to 14
  • Stationary Phase
  • Ethylvinylbenzene/Divinylbenzene Substrate
  • Column Type
  • Guard Column
  • Phase
  • Ethylvinylbenzene/Divinylbenzene Substrate
  • Unit Size
  • Each
  • Type
  • Guard Column
  • Description
  • CarboPac PA210-4µm Guard Column
  • Column Capacity
  • 66 µeq
  • Flow Rate
  • 0.2 to 0.8 mL/min.
  • For Use With (Application)
  • Carbohydrate Analysis
  • For Use With (Equipment)
  • CarboPac PA210-4µm Analytical Column
  • Solvent Compatibility
  • pH 0 to 14, 80% Compatible with Common HPLC Solvents
  • Solvents
  • Particle Size
  • Column Construction
  • PEEK
  • Resin Composition
  • 4 µm Diameter Ethylvinylbenzene/Divinylbenzene Substrate (55% Cross-Linking) Agglomerated with 43 nm MicroBead 6% Cross-Linked Quaternary Amine-Functionalized Latex
  • Temperature (Metric)
  • 30°C (Recommended)
  • Pressure
  • 4000 psi (275 bar)
  • Compatibility
  • pH 0 to 14, 80% Compatible with Common HPLC Solvents
THM088956 Dionex™ CarboPac™ PA210-Fast-4µm Column, 4 µm, 2 × 30 mm 757.81 
Add to Cart
  • Max. Pressure
  • 4000 psi (275 bar)
  • pH
  • 1 to 14
  • Stationary Phase
  • Ethylvinylbenzene/Divinylbenzene Substrate
  • Column Type
  • Guard Column
  • Phase
  • Ethylvinylbenzene/Divinylbenzene Substrate
  • Unit Size
  • Each
  • Type
  • Guard Column
  • Description
  • CarboPac PA210-4µm Guard Column
  • Column Capacity
  • 66 µeq
  • Flow Rate
  • 0.2 mL/min. (Recommended)
  • For Use With (Application)
  • Carbohydrate Analysis
  • For Use With (Equipment)
  • CarboPac PA210-4µm Analytical Column
  • Solvent Compatibility
  • pH 0 to 14, 80% Compatible with Common HPLC Solvents
  • Solvents
  • Particle Size
THM088956 Dionex™ CarboPac™ PA210-Fast-4µm Column, 4 µm, 2 × 30 mm 757.81 
Add to Cart
  • Max. Pressure
  • 4000 psi (275 bar)
  • pH
  • 1 to 14
  • Stationary Phase
  • Ethylvinylbenzene/Divinylbenzene Substrate
  • Column Type
  • Guard Column
  • Phase
  • Ethylvinylbenzene/Divinylbenzene Substrate
  • Unit Size
  • Each
  • Type
  • Guard Column
  • Description
  • CarboPac PA210-4µm Guard Column
  • Column Capacity
  • 66 µeq
  • Flow Rate
  • 0.2 mL/min. (Recommended)
  • For Use With (Application)
  • Carbohydrate Analysis
  • For Use With (Equipment)
  • CarboPac PA210-4µm Analytical Column
  • Solvent Compatibility
  • pH 0 to 14, 80% Compatible with Common HPLC Solvents
  • Solvents
  • Particle Size
  • Column Construction
  • PEEK
  • Resin Composition
  • 4 µm Diameter Ethylvinylbenzene/Divinylbenzene Substrate (55% Cross-Linking) Agglomerated with 43 nm MicroBead 6% Cross-Linked Quaternary Amine-Functionalized Latex
  • Temperature (Metric)
  • 30°C (Recommended)
  • Pressure
  • 4000 psi (275 bar)
  • Compatibility
  • pH 0 to 14, 80% Compatible with Common HPLC Solvents
THM088953 Dionex™ CarboPac™ PA210-Fast-4µm Column, 4 µm, 4 × 150 mm 2326.37 
Add to Cart
  • Max. Pressure
  • 4000 psi (275 bar)
  • pH
  • 1 to 14
  • Stationary Phase
  • Ethylvinylbenzene/Divinylbenzene Substrate
  • Column Type
  • Analytical Column
  • Phase
  • Ethylvinylbenzene/Divinylbenzene Substrate
  • Unit Size
  • Each
  • Type
  • Analytical Column
  • Description
  • CarboPac PA210-4µm Analytical Column
  • Column Capacity
  • 66 µeq
  • Flow Rate
  • 0.2 to 0.8 mL/min.
  • For Use With (Application)
  • Carbohydrate Analysis
  • Solvent Compatibility
  • pH 0 to 14, 80% Compatible with Common HPLC Solvents
  • Solvents
  • Particle Size
  • Column Construction
  • PEEK
  • Resin Composition
  • 4 µm Diameter Ethylvinylbenzene/Divinylbenzene Substrate (55% Cross-Linking) Agglomerated with 43 nm MicroBead 6% Cross-Linked Quaternary Amine-Functionalized Latex
  • Temperature (Metric)
  • 30°C (Recommended)
  • Pressure
  • 4000 psi (275 bar)
  • Compatibility
  • pH 0 to 14, 80% Compatible with Common HPLC Solvents
THM088954 Dionex™ CarboPac™ PA210-Fast-4µm Column, 4 µm, 2 × 150 mm 2326.37 
Add to Cart
  • Max. Pressure
  • 4000 psi (275 bar)
  • pH
  • 1 to 14
  • Stationary Phase
  • Ethylvinylbenzene/Divinylbenzene Substrate
  • Column Type
  • Analytical Column
  • Phase
  • Ethylvinylbenzene/Divinylbenzene Substrate
  • Unit Size
  • Each
  • Type
  • Analytical Column
  • Description
  • CarboPac PA210-4µm Analytical Column
  • Column Capacity
  • 66 µeq
  • Flow Rate
  • 0.2 mL/min. (Recommended)
  • For Use With (Application)
  • Carbohydrate Analysis
  • Solvent Compatibility
  • pH 0 to 14, 80% Compatible with Common HPLC Solvents
  • Solvents
  • Particle Size
  • Column Construction
  • PEEK
  • Resin Composition
  • 4 µm Diameter Ethylvinylbenzene/Divinylbenzene Substrate (55% Cross-Linking) Agglomerated with 43 nm MicroBead 6% Cross-Linked Quaternary Amine-Functionalized Latex
  • Temperature (Metric)
  • 30°C (Recommended)
  • Pressure
  • 4000 psi (275 bar)
  • Compatibility
  • pH 0 to 14, 80% Compatible with Common HPLC Solvents
THM35005-012101 Hypercarb™ Porous Graphitic Carbon HPLC Column, 5 μm, 2.1 × 10 mm 732.41 
Add to Cart
  • Max. Pressure
  • 5800 psi (400 bar)
  • pH
  • 0 to 14
  • Pore Size
  • 250 Å
  • Surface Area
  • 120 m²/g
  • Stationary Phase
  • Porous Graphitic Carbon
  • Product Line
  • Hypercarb
  • Packing Material
  • Porous Graphitic Carbon
  • Carbon Load
  • 100%
  • Column Type
  • Reversed Phase
  • Phase
  • Porous Graphitic Carbon
  • Unit Size
  • Pack of 2
  • Type
  • Guard Cartridge
  • For Use With (Equipment)
  • Uniguard Direct-Connection and Stand Alone Holder
  • Quantity
  • 2 Pk.
  • Pressure
  • 5800 psi (400 bar)
THM35005-013001 Hypercarb™ Porous Graphitic Carbon HPLC Column, 5 μm, 3 × 10 mm 738.77 
Add to Cart
  • Max. Pressure
  • 5800 psi (400 bar)
  • pH
  • 0 to 14
  • Pore Size
  • 250 Å
  • Surface Area
  • 120 m²/g
  • Stationary Phase
  • Porous Graphitic Carbon
  • Product Line
  • Hypercarb
  • Packing Material
  • Porous Graphitic Carbon
  • Carbon Load
  • 100%
  • Column Type
  • Reversed Phase
  • Phase
  • Porous Graphitic Carbon
  • Unit Size
  • Pack of 2
  • Type
  • Guard Cartridge
  • For Use With (Equipment)
  • Uniguard Direct-Connection and Stand Alone Holder
  • Quantity
  • 2 Pk.
  • Pressure
  • 5800 psi (400 bar)

Overview

Solve your chromatography challenges with our extensive portfolio of HPLC and UHPLC columns designed to meet all of your separation needs. Bringing you a 40-year legacy of innovation, Thermo Scientific (U)HPLC columns offer an unmatched variety of chemistries, from the most popular C18 phases, to innovative mixed-mode chemistries, to the broadest range of solid core columns on the market, and more. We design our columns with everything you expect from a high-quality (U)HPLC column: high resolution, enhanced sensitivity, faster analysis, consistent performance, long column lifetime, and reproducibility. Each of our column types is available in a range of particle sizes and column formats so you can select the column best suited to your workflow.


Resources