Agilent Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is available in single quadrupole and triple quadrupole configurations. Our single quadrupole ICP-MS address the range of typical ICP-MS measurements from routine, regulated analysis to advanced research and demanding applications. Our triple quadrupole ICP-MS will give you the confidence of knowing you can resolve problematic interferences – even in your most difficult samples – delivering results you know you can trust.

Catalog No. Product Net Price
AGIL2010083400 Spare semi-demountable quartz torch body, for axial 700, Vista, and Liberty Series ICP-OES 762 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Chemical Compatibility
  • Aqueous Organic solvents
AGIL2010095300 Replacement quartz intermediate tube for axial and radial 700, Vista, and Liberty Series ICP-OES fully demountable torch 267 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Chemical Compatibility
  • Aqueous Organic solvents
AGIL2010095500 Quartz outer tube for radial 700, Vista, and Liberty Series ICP-OES fully demountable torch. 231 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Chemical Compatibility
  • Aqueous Organic solvents
AGIL2010095800 Ceramic outer tube for radial 700, Vista, and Liberty Series ICP-OES fully demountable torch. 4612 
Add to Cart
  • Chemical Compatibility
  • Aqueous HF acid Organic solvents
AGIL2010120300 Quartz outer tube for high solid samples for axial 700, Vista, and Liberty Series ICP-OES fully demountable torch. 280 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Chemical Compatibility
  • Aqueous
AGIL3710033400 Tubing 1/4 in id and 3/8 in od. Used on 5000 series ICP-OES To connect sample drain tray to waste and as spray chamber to torch tubing for 700, liberty, and vista series ICP-OES. Sold per meter of tubing. 26 
Add to Cart
  • Inner Diameter (ID)
  • 0.25 in
  • Length
  • 1 m
  • UNSPSC Code
  • 41115411
  • Chemical Compatibility
  • Aqueous
  • Notes
  • Connects sample tray to waste container
  • Tubing Material
  • PVC
  • Tubing OD
  • 0.375 in
  • Where Used
  • Waste
AGIL7910044500 Spare fully demountable torch body, for radial 700, Vista, and Liberty Series ICP-OES 2299 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Chemical Compatibility
  • Aqueous Organic solvents
AGIL9910056800 Semi-demountable inert torch assembly for radial 700 Series, Vista Series, and Liberty ICP-OES. For analysis of samples containing hydrofluoric (HF) acid. Includes low-flow torch body, 1.8 mm id alumina injector and injector holder. Also requires 1m conne 990 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Chemical Compatibility
  • Aqueous HF acid
  • Notes
  • Application: Samples with free HF when used with an inert alumina injector (p/n 2410067590); for volatile organic solvents, use narrow bore 0.8 mm id quartz injector (p/n 2010077500)
  • Type
  • HF acid
AGIL9910057300 Injector holder kit for semi-demountable torch. Includes injector bung for semi-demountable torch, 3 O-rings 134 
Add to Cart
  • UNSPSC Code
  • 41115411
AGIL9910106300 Fully demountable inert torch assembly kit for axial 700, Vista and Liberty Series ICP-OES. For analysis of samples containing hydrofluoric (HF) acid. Includes low-flow torch body, 1.8 mm id alumina injector tube, injector holder 3303 
Add to Cart
  • UNSPSC Code
  • 41115411
  • Chemical Compatibility
  • Aqueous HF acid
  • Type
  • HF acid

Overview

ICP-MS system operates with an ICP-MS Nebulizer, in which a high velocity Argon gas stream meets a liquid stream causing filmwise breakup of the solution into a fine aerosol. The aerosol particle size should ideally be sub-10µm with a narrow particle size distribution to achieve efficient atomization and ionization. Agilent offers a comprehensive range of ICP-MS nebulizers and supplies to solve any ICP-MS analysis challenge.

The portfolio includes standard glass concentric nebulizer (MicroMist), quartz and inert PFA nebulizers (MicroFlow and C-Flow), as well as robust Mira Mist PEEK or PTFE for high TDS samples and low-flow self-aspirating or total consumption nebulizers for your clinical or limited volume samples. ICP-MS nebulizer support is provided with a full range of accessories for all models including nebulizer cleaning tools.


The ICP torch is used to form, shape, and sustain an argon plasma which atomizes and ionizes the sample aerosol. Agilent ICP-MS Torches with Shield Torch System (STS) provide precise ion energy control, ensuring high sensitivity and stability, even in cool plasma mode for effective interference removal (ArO+).

Our portfolio is comprised of a wide range of ICP torches for your specific ICP-MS configuration. One-piece quartz torches offer the best stability and ease of use. The large 2.5mm injector on the standard torch gives maximum robustness and lowest matrix interferences for the best plasma stability. Single-piece torches with narrow bore injectors (1.0mm or 1.5 mm) are designed for use with organic solvents, to reduce plasma loading and improve plasma stability. Optional semi-demountable quartz torches with removable platinum or sapphire injectors are also available for use with the PFA inert sample introduction kit.