+852-3069 6950
sales@gugent.com.hk
Catalog No. CYT18112974
Part No. 18112974
Supplier Cytiva
Monitor UPC-900
Net Price
Special offer
Availability

4 weeks

PROPERTIES
  • Material
    Polyetheretherketone (PEEK)\nPolytetrafluoroethylene (PTFE)\nTitanium alloy (Ti alloy)\nQuartz
  • Operating pressure max.
    50 bar (5 MPa) (725 psi)
  • Operating Temperature
    4°C-60°C
  • Weight
    8.5
  • Height
    200 mm
  • Wetted Part
    No
  • Guidance
    Other available monitors\nMonitor UVis-920\n11-0007-54\nMonitor UV-900 \n18-1108-35
  • Includes
    Hg optics, 254 and 280 nm filters, 2 mm UV flow cell, conductivity flow cell, signal cable and flow cell holder. (pH electrode and flow cell can be ordered separately if desired.)
  • Relative humidity
    20%-95% (non condensing)
  • Width
    160
  • Depth
    250 mm
  • Voltage
    100-120/220-240 VAC
  • Protection class
    IP 20, IP 21 (Housing) \nIP 44 (Flow cell)
  • pH Stability Long Term
    1-13
  • pH Stability Short Term
    1–14
DESCRIPTION
Monitor UPC-900 is a high precision on-line monitor offering the possibility to measure UV, conductivity, and pH using a single instrument. Real chromatographic information at a glance. Three monitors in one unit: UV, pH, and conductivity. Operates as an integral component of ÄKTAFPLC or as a standalone unit. Flow cells fit tightly in series to minimize dead volume and band-broadening effects. Wide range of select, high specificity UV wavelengths using a mercury or zinc lamp. Designed for all chromatographic techniques used in analysis and purification of biomolecules. Monitor UPC-900 provides UV and temperature-compensated pH and conductivity parameters in a single display. Temperature is monitored and displayed and can be recorded if the monitor is used in ÄKTAdesign systems. The mercury lamp is available with 254 or 280 nm filters for detecting proteins; the zinc lamp is used with the 214 nm filter for detecting peptides or for increased protein detection sensitivity. Additional filters are available for special applications within the range of 313 to 546 nm. The 2 mm UV flow cell and the pH and conductivity flow cells are designed to accommodate flow rates up to 100 ml/min; the 5 mm UV flow cell is optimized for flow rates to 20 ml/min.The conductivity monitor features a broad dynamic range that accommodates the high salt concentrations used in hydrophobic interaction chromatography and the low conductivity of reversed phase or desalting separations. The pH monitor is essential for optimal results in affinity, ion exchange, and chromatofocusing separations.