+852-3069 6950
sales@gugent.com.hk
Catalog No. CYT17085101
Part No. 17085101
Supplier Cytiva
Disposable PD-10 Desalting Column, with Sephadex G-25 resin, 1.0–2.5 mL samples
Net Price
429
Availability

4 weeks

PROPERTIES
  • Bed volume
    8.3
  • Pack size
    30 columns
  • Bed height
    50 mm
  • Order Information
    Disposable columns for clean-up of proteins/oligosaccharides. \nThe columns are prepacked with Sephadex G-25 resin and for sample volumes up to 2.5 mL by gravity flow and columns spin flow.\nPD- 10 Buffer reservoir has to be ordered separately\nFor smaller scale please use PD MidiTrap G-25 (1.0 mL), PD MiniTrap G-25 (0.5 mL), PD SpinTrap G-25 (130 µL) and PD MultiTrap G-25 (130 µL) in parallel
  • Column i.d.
    14.5
  • Wetted Part
    No
  • Sample volume
    2.5 ml
  • Storage
    4 to 30°C, 0.15% Kathon CG/ICP Biocide
  • Bed dimensions
    14.5 × 50 mm
  • Includes
    1 × Column stand\n4 × PD-10 spin adaptor\n1 × Buffer tray\n30 × Bottom sleeve\nInstructions are supplied with the columns
DESCRIPTION
PD-10 Desalting Columns contain Sephadex G-25 resin for rapid buffer exchange, desalting, and removal of small contaminants (salts, dyes, radioactive labels) from samples using gravity flow or centrifugation. Flexible run protocols – perform desalting and buffer exchange using gravity flow (1.0 to 2.5 mL samples) or centrifugation (1.75 to 2.5 mL samples) Flexible throughput – desalt one sample or multiple samples in parallel Good recovery – in the range of 70% to > 95% High desalting capacity – remove > 98% salt with gravity; > 90% with centrifugation Minimal dilution – typically none when used as spin columns; 1.4× when used with gravity flow Time savings compared to dialysis – inexpensive and convenient alternative to lengthy and troublesome dialysis procedures What comes in the PD-10 column package?Each product pack includes 30 columns, a buffer tray, a column stand, and 4 adapters for centrifugation. Versatile for use with centrifugation or gravity flowThe product instructions include two protocols. The gravity protocol allows simple processing of samples using one or several columns in parallel, without the need for a purification system. The spin protocol enables runs in parallel in a standard centrifuge with minimal dilution of the eluted sample.Successful use of these prepacked desalting columnsThe following publications demonstrate the utility of PD-10 columns: desalting of membrane proteins after anion exchange chromatography desalting of variants of an essential reductase involved in fatty acid biosynthesis buffer exchange of an affinity-tagged acyl carrier protein Accessories for PD-10 Desalting ColumnsA LabMate buffer reservoir can be used for one-step application of the column wash and equilibration buffer using the gravity flow protocol. It is not included with this product but can be purchased separately.Other Sephadex G-25 columns from CytivaCytiva's solutions for desalting include a wide range of columns containing Sephadex G-25 resin. Options are available to accommodate sample volumes from 100 µL to 15 mL and use with manual methods or a chromatography system. Let Cytiva help you find the right desalting product.