In stock
Agilent Technologies AGIL122-7012UI-INT
J&W DB-WAX Ultra Inert Intuvo GC column module, 15 m, 0.25 mm, 0.25 µm. (compatible only with the Intuvo 9000 GC System)
470 /Each
Agilent Technologies AGIL121-5522UI-INT
J&W DB-5ms Ultra Inert Intuvo GC column module, 20 m, 0.18 mm, 0.18 µm. (compatible only with the Intuvo 9000 GC System)
716 /Each
Pall Corporation HC9404FRP26HYP95
Supralon GlassFiber 5 micron (Beta 2000) Nitrile 26in 66.04cm
Special offer /Each
Regis Technologies, Inc. REG1-590308-300
REFLECT C-Cellulose B - 10 µm, 1000Å, 25 cm x 50.0 mm ID
38448 /Each
Merck KGaA MK87009019
Vantage S2 and A2 Routine Maintenance Kit V90
502 /Each
Agilent Technologies AGIL5067-4652
Capillary stainless steel 0.12 x 120 mm SX/SX ps/ps
76 /Each
Merck KGaA CN0672E06
Polygard-CN Cartridge Filter 20 in. 0.6 µm Code 7 Ethylene-Propylene
1568 /Each
Agilent Technologies G3285-80001
Nebulizer, C-Flow with Agilent I-AS probe, inert PFA, self-aspirates at 200 μL/min. For use with Agilent integrated autosampler (I-AS), for trace analysis and hydrofluoric acid (HF), self-aspirates with integrated sample probe. Optional for all Agilent IC
1971 /Each
Waters Corporation WATS-430001534
Tubing Assembly, Accumulator A Transducer to Vent Valve P3
104 /Each
Cytiva CYT11002688
Ettan™ IPGphor™ Cup Loading Manifold Light with Plastic Tray
1506 /Each
Agilent Technologies AGIL0101-0300
Sample loop, GC valve, stainless steel, 2.0 mL
72 /Each
Agilent Technologies AGIL122-0733-INT
J&W DB-1701 Intuvo GC column module, 30 m, 0.25 mm, 1.00 µm. (compatible only with the Intuvo 9000 GC System)
745 /Each
Agilent Technologies AGIL0515-2711
Screw, M4 x 07 12 mm (long) panhead, used with series 6820, 6850, 6890, 7820, and 7890 gas chromatography systems, and series 7697 headspace sampler systems, model 7697A
7 /Each
SHIMADZU CORPORATION 670-11518-00
O-ring, VP Series, LC-2010/HT Drain Valve
16 /Each
Agilent Technologies CP7596-INT
J&W CP-Sil 8 CB for Amines Intuvo GC column module, 30 m, 0.32 mm, 1 µm. (compatible only with the Intuvo 9000 GC System)
884 /Each
Pall Corporation HC572FCP9H
Coralon Glass Fiber 5 micron (Beta 1000) Nitrile 9in 22.86cm (REPLACED BY HC572FRP9Z)
265 /Each
Cytiva CYT80649857
IPGphor™ Manifold Ceramic Tray
4376 /Each
SHIMADZU CORPORATION 036-19004-03
O-RING, 4D S6
Agilent Technologies AGIL0905-1284
C-ring, metal, bottom
121 /Each
Agilent Technologies AGIL122-1334UI-INT
J&W DB-624 Ultra Inert Intuvo GC column module, 30 m, 0.25 mm, 1.40 µm. (compatible only with the Intuvo 9000 GC System)
826 /Each
Agilent Technologies AGIL6040-0834
Agilent Vacuum Fluid 45 Gold, 1 Liter. This Part Number is being moved to an obsolete status and will no longer be available for sale. ICP-MS replacement Part Number: X3760-64004. Other Mass Spectrometry replacement Part Numbers: 5191-5851
Agilent Technologies G3285-80016
Obsolete. No replacement recommendation. Inert sample introduction kit, 1.5 mm id sapphire injector tube, for Agilent 7500 ICP-MS, replaces standard sample introduction system with an inert system for volatile organic samples, requires but does not includ
Thermo Fisher Scientific Inc. THM-TDE50040LDRK
TDE Series -40°C Ultra-Low Temperature Freezer Package with Racks and Boxes
Regis Technologies, Inc. REG1-593217-300
REFLECT I-Cellulose C, Guard Column - 5 µm, 1 cm x 3.0 mm ID (Qty of 3)
338 /Each
Cytiva CYT18112116
FEP Tubing, 3 m, i.d. 1/16
54 /Each
SHIMADZU CORPORATION 036-11267-00
O-Ring, 4D P95
24 /Each
Agilent Technologies AGIL122-0314UI-INT
Agilent J&W DB-Select 624 Ultra Inert Intuvo GC column module, 15 m, 0.25 mm, 1.40 µm. (Compatible only with the Intuvo 9000 GC System)
520 /Each
Agilent Technologies G7129-87112
Needle seat, Vespel, 0.12 mm ID capillary, for 1290 Infinity II vial sampler
213 /Each
SHIMADZU CORPORATION 228-35601-91
Ceramic plunger, LC-20AD/AB/10ADvp
162 /Each
SHIMADZU CORPORATION 036-12521-00
O-RING 4D G115 LCMS-2010EV
14 /Each