+852-3069 6950
sales@gugent.com.hk
Catalog No. KHGEG3TTT1H
Part No. KHGEG3TTT1H
Supplier Merck KGaA
Gamma Compatible High Area Opticap® XLT 30 Millipore Express® SHC 0.5  µm/0.2 µm 1-1/2 in. TC
Net Price
Special offer
Availability

4 weeks

PROPERTIES
  • Bacterial Endotoxins
    Aqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
  • Bacterial Retention
    Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
  • Cartridge Nominal Length
    30 in. (75 cm)
  • Catalogue Number
    KHGEG3TTT1H
  • Chemistry
    Hydrophilic Polyethersulfone (PES)
  • Device Material
    Polypropylene/Polysulfone
  • Device Size
    30 in.
  • Diameter
    10.7 in. (4.2 cm)
  • Filtration Area
    30000 cm2
  • Good Manufacturing Practices
    These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Housing Material
    Polypropylene (PP)
  • Indirect Food Additive
    All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Inlet Connection
    Sanitary Flange
  • Inlet to Outlet Width
    15.2 cm (6.0 in.)
  • Key Applications
    Laboratory Filtration
  • Length
    30 in. (75 cm)
  • Material Package
    Double Easy-Open bag
  • Material Size
    1
  • Maximum Differential Pressure, bar (psid)
    Forward: 6.9 (100) intermittent @ 25 °C; 5.5 (80) @ 25 °C; 1.0 (15) @ 80 °C. Reverse: 2.1 (30) @ 25 °C, intermittent
  • Maximum Inlet Pressure (psig)
    80
  • Maximum Inlet Pressure, bar (psi)
    6.9 (100) intermittent @ 25 °C; 5.5 (80) @ 25 °C; 2.75 (40) @ 60 °C; 1.0 (15) @ 80 °C
  • Maximum Inlet Temperature
    25°C
  • Non-Fiber Releasing
    This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
  • Outlet Connection
    Sanitary Flange
  • Outlet Connection Diameter
    1.5 in.
  • Oxidizable Substances
    Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥6 L
  • Pore Size
    0.5 / 0.2 µm
  • Seal Material
    Silicone (SI)
  • Sterility
    Non-Sterile
  • Sterilization
    Gamma compatible to 45 kGy; 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
  • Support Material
    Polyester
  • Trade Name
    Millipore Express®
  • Vent Cap Material
    Polypropylene (PP)
  • Wettability
    Hydrophilic
  • Width
    15.2 cm (6.0 in.)