Durapore Cartridge Filter 10 in. 0.22 µm hydrophobic Code 7
Net Price
994
Availability
4 weeks
PROPERTIES
Bacterial Endotoxins
Aqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Bacterial Retention
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
Cartridge Code
Code 7
Cartridge Nominal Length
10 in. (25 cm)
Catalogue Number
CVGB71TP3
Chemistry
Polyvinylidene Fluoride (PVDF)
Device Configuration
Cartridge
Device Material
Polypropylene
Device Size
10 in.
Diameter
6.9 cm (2.7 in.)
Filtration Area
0.69 m²
Good Manufacturing Practices
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Gravimetric Extractables
The extractables level was equal to or less than 20 mg per 10-inch cartridge after 24 hours in a 70/30% IPA/water mixture at controlled room temperature.
Length
10 in. (25 cm)
Material Package
Double Easy-Open bag
Material Size
3
Maximum Differential Pressure, bar (psid)
Forward: 5.5 bar (80 psid) @ 25 °C; 1.7 bar (25 psid) @ 80 °C; 0.35 bar (5 psid) @ 135 °C. Reverse: 3.5 bar (50 psid) @ 25 °C
Maximum Inlet Pressure, bar (psi)
Forward - 5.5 bar (80 psi) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; 0.35 bar (5 psi) @ 135 °C; Reverse - 3.5 bar (50 psi) @ 25 °C
Media
Durapore®
Non-Fiber Releasing
This product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Pore Size
0.22 µm
Seal Material
Silicone (SI)
Sterilization
30 SIP cycles of 30 min @ 126 °C; 30 autoclave cycles of 60 min @ 126 °C
Support Material
Polypropylene
Trade Name
Durapore®
USP Bacterial Endotoxins
A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.