Bacterial Endotoxins
Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
-
Bacterial Retention
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
-
Cartridge Nominal Length
10 in. (25 cm)
-
Catalogue Number
KTGRA10TT1
-
Chemistry
Polytetrafluoroethylene (PTFE)
-
Device Configuration
Capsule
-
Device Material
Polypropylene
-
Device Size
10 in.
-
Diameter
10.7 cm (4.2 in.)
-
European Pressure Equipment Directive
EMD Millipore Corporation certifies that this product complies with the European Pressure Equipment Directive, 2014/68/EU of 15 May 2014. This product has been classified under Article 4 § 3 of the Directive 2014/68/EU. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 4 § 3 of the Directive 2014/68/EU, this product does not bear the CE mark.
-
Filtration Area
0.65 m²
-
Gravimetric Extractables
The extractables level was equal to or less than 45 mg per 10-inch cartridge after 24 hours in a 70/30% IPA/water mixture at controlled room temperature.
-
Housing Material
Polypropylene (PP)
-
Inlet Connection
Sanitary Flange
-
Inlet Connection Diameter
1-1/2 in.
-
Inlet to Outlet Width
33.5 cm (13.2 in.)
-
Length
10 in. (25 cm)
-
Material Package
Double Easy-Open bag
-
Material Size
1
-
Maximum Differential Pressure, bar (psid)
Forward: 5.5 bar (80 psid) @ 25 °C; 1.0 bar (15 psid) @ 80 °C. Reverse: 4.1 bar (60 psid), intermittent
-
Maximum Inlet Pressure (psig)
80 psig
-
Maximum Inlet Pressure, bar (psi)
Forward - 5.5 bar (80 psi) @ 25 °C; 2.8 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C; Reverse - 4.1 bar (60 psi), Intermittent
-
Maximum Inlet Temperature
25 °C
-
Media
Aervent®
-
Non-Fiber Releasing
This product was manufactured with a PTFE membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
-
Outlet Connection
Sanitary Flange
-
Outlet Connection Diameter
1-1/2 in.
-
Pore Size
0.2 µm
-
Seal Material
Silicone (SI)
-
Sterilization
30 autoclave cycles of 30 min @ 135 °C
-
Support Material
Polypropylene
-
Trade Name
Aervent®
-
USP Bacterial Endotoxins
Aqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
-
Vent Cap Material
Polypropylene (PP)
-
Wettability
Hydrophobic
-
Width
33.5 cm (13.2 in.)